PUR HEPA PD-HEPADM400-VS Скачать руководство пользователя страница 2

SAFETY CONSIDERATIONS 

Read  and  follow  instructions  carefully.  Follow  all  local 

electrical  codes  during  installation.  All  wiring  must 

conform  to  local  and  national  electrical  codes. 

Improper wiring or installation may damage the HEPA 

Air Cleaner. 

Understand  the  signal  words 

WARNING

  and 

CAUTION

 which are present in the Owner’s Manual. 

WARNING 

and 

CAUTION

  signify  a  hazard  which 

could  result  in  property  damage,  personal  injury  or 

death. 

Only a heating/air conditioning installer or qualified 

service  person  should  install,  repair,  or  service 

your Whole-House HEPA Air Cleaner. 
Homeowners  or  untrained  personnel  can  perform 

the  basic  maintenance  functions  of  replacing 

filters. 
When working on air cleaning equipment, observe 

precautions in the Owner’s Manual, labels attached 

to  the  unit,  and  other  safety  precautions  that  may 

apply. Follow all safety codes. Wear safety glasses 

and work gloves. 

WHAT THE HEPA AIR CLEANER DOES 

The  Whole-House  HEPA  Air  Cleaner  has  been 

designed  to  remove  particulate  such  as  atmospheric 

and household dust, coal dust, insecticide dust, mites, 

pollen,  mold  spores,  fungi,  bacteria,  viruses,  pet 

dander,  cooking  smoke  and  grease,  tobacco  smoke 

and  more.  It  also  removes  odours  with  the  Carbon 

Filter. 

BENEFITS 

 

Helps  provide  relief  from  allergies,  asthma,  and 

other respiratory illness. 

 

Helps reduce housekeeping time and redecorating 

costs. 

 

Helps  provide  a  healthier,  more  comfortable 

environment, year-round. 

HOW IT WORKS 

Millions  of  airborne  pollutants  are  carried  through  the 

return  air  ducts  of  the  heating/cooling  system.  The 

HEPA  Air  Cleaner  has  been  designed  to  be  installed 

on the return air duct.  A portion of this return air is by-

passed through an opening on the rear of the unit and 

passes through a 3-stage filtration system. 
The  air  passes  through  an  efficient  pleated  MERV  11 

Prefilter to remove lint and large particles to extend the 

life of the HEPA filter. 
The  Activated  Carbon  Prefilter  (activated  carbon 

impregnated  polyester  filter)  removes  odours  before 

they enter the HEPA filter. 
Smaller  particles  then  pass  through  a  long-life,  HEPA 

(High  Efficiency  Particulate  Air)  Media  Filter  which 

captures  99.97%  of  particles  0.3  micron  (1/84,000  of 

an  inch)  and  larger.      This  HEPA  filter  has  more  than 

40 ft² of collection surface area. 
Clean air is discharged back into the return air duct. 

INSTALLATION 

Duct Mount Installation 

LOCATION 

The HEPA Air Cleaner can be installed directly on the 

return air duct eliminating the need for external ducting. 

The unit can also be mounted on the floor, a wall or be 

suspended from the ceiling and with the use of collars 

be  ducted  into  the  return  air  plenum.    It  can  also  be 

used as a free standing unit.  Care should be taken to 

keep  the  unit  away  from  an  area  where  there  is  a 

possibility of moisture leaking on to it.  

Ensure  there  is 

13  inches  in  front  of  the  unit  to  remove  the  filters 

for replacing.

 

 

GENERAL INSTALLATION STEPS (Duct Mount) 

1.  Remove  any  packaging,  as  well  as  the  door  and 

filters  before  installing.  See  Maintenance  for 

instructions to remove the filters. 

2.  If  the  unit  is  to  be  mounted  on  the  return  air 

plenum,  it  must  be  installed  after  the  last  return 

branch connection on the plenum.  If outside air is 

introduced into the return air duct, either through a 

HRV (Heat Recovery Ventilator) or direct, it should 

be  added  to  the  system  before  the  intake  inlet  to 

the Air Cleaner.  

 

 

3.  Tape  the  mounting  template  level  on  the 

plenum  and  proceed  to  cut  and  drill  the 

necessary holes as marked. 

4.  Cut  the  small  joints  on  the  mounting  flaps  on 

the back of the unit as indicated.  Bend all the 

WARNING  

Before  beginning  any  installation  or  modification,  be 

certain that the main line electrical disconnect switch 

is in the 

OFF

 position. Electric shock could result. Tag 

disconnect switch with suitable warning labels.  

WARNING  

This  unit  must  be  installed  on  the  return  air  side  of 

the system only. Do not connect to supply side. 

Do not install in a cooking area or connect directly to 

any appliance.  

Содержание HEPA PD-HEPADM400-VS

Страница 1: ...oves lint and large particles to extend life of HEPA Filter Activated Carbon Prefilter removes unpleasant odours Easy to change filters Powerful motor delivers up to 320 CFM of filtered air Heavy gaug...

Страница 2: ...A filter The Activated Carbon Prefilter activated carbon impregnated polyester filter removes odours before they enter the HEPA filter Smaller particles then pass through a long life HEPA High Efficie...

Страница 3: ...ge Secure with the screws provided 3 The intake collar on the return duct must be installed after the last return branch connection on the plenum If outside air is introduced into the return air duct...

Страница 4: ...ore installing Discard plastic safely Take care not to damage the filters Hold by the frame only 4 Date the replacement filter in the space provided 5 Place the filters in their appropriate track with...

Страница 5: ...s the unused portion of the warranty Failing this PUR DISTRIBUTION LTD will guarantee the unit for a period of sixty 60 months from the date of manufacture according to the manufacturer s records THIS...

Страница 6: ......

Страница 7: ...ie du filtre HEPA Pr filtre au charbon activ pour limine les odeurs d sagr ables Filtres faciles changer La vitesse variable puissante le moteur europ en fournit jusqu 320 CFM d air propre Le caisson...

Страница 8: ...particules plus petites traversent ensuite un filtre m dia HEPA durable de 99 97 air particules de haute efficacit qui retient les particules de 0 3 micron 1 84 000 de pouce et plus grosses Le filtre...

Страница 9: ...d admission sur le conduit de retour doit tre install apr s le dernier raccordement de retour sur le pl num Si de l air ext rieur p n tre dans la canalisation de retour d air soit par un ventilateur...

Страница 10: ...stique Prendre soin de ne pas endommager les filtres Tenir le filtre uniquement par son cadre 4 Indiquer la date de remplacement du filtre dans l espace pr vu 5 Placer les filtres dans leur rainure ap...

Страница 11: ...dition l entretien ou la manutention de soit les pi ces d fectueuses ou les pi ces de rechange LIMITES DE LA GARANTIE Toutes garanties implicites y compris garanties implicites de commercialisation s...

Страница 12: ...E PLASTIC PACKAGING ON INSIDE FILTERS ENLEVER LA PELLICULE DE PLASTIQUE DES FILTRES REFER TO OWNER S MANUAL FOR INSTALLATION INSTRUCTIONS VOIR LES DIRECTIVES DANS LE MANUEL D INSTALLATION QUESTIONS DE...

Отзывы: