OPERATION INSTRUCTIONS
Before Starting
WARNING: Check hoses, trigger guns, fittings, and fuel connections daily for signs of wear, cracks and
looseness, and replace as required.
1. Read all manuals provided with this pressure washer. Become familiar with location and function of all operating and safety
controls.
2. Connect water supply hose to the standard garden hose connector. The water source and supply hose must be capable of
providing 30 LPM.
3. Fill fuel tank. Use Diesel
DO NOT USE PETROL, CRANKCASE OIL RESIDUALS OR WASTE OIL.
4. Check pump oil level.
5. If detergents are to be used, only use detergents intended for pressure washers. Follow instructions on the detergent container.
IMPORTANT: If the pressure washer has not been used for an extended period of time, remove the nozzle from the end of
the wand and turn on water supply. Allow water to run from the end of the wand until clear.
IMPORTANT: Trigger guns are equipped with a manual trigger lock to prevent accidental operation of the
trigger gun. The trigger lock should be used whenever the trigger gun is not in use.
To Start
IMPORTANT: The water must be turned on before starting. Running the pump dry will cause damage to pump seals and
void warranty.
IMPORTANT: DO NOT allow the machine to run in bypass for more than 5 minutes at any one time or
damage to pump may occur.
1. Turn Key to ON for Engine.
(Ref. Fig 1)
2. Hold gun firmly, squeeze trigger of trigger gun and run your unit on cold water, to make sure everything is in
working order.
3. Press the On/Off Button.
(Ref. Fig 2)
4. Turn the Thermostate to select desired temperature.
(Ref. Fig 3)
To Stop
1. Turn the Thermostat to 0
(Ref. Fig 4)
2. Press the On/Off Buton to off
(Ref. Fig 5)
3. Allow cold water to run through the boiler for 1-2 Minutes.
4. Turn Key to OFF your pressure washer.
(Ref. Fig 6)
5. Squeeze trigger gun open to relieve system pressure.
Fig. 2
Press Button - Light Indicates On
Fig. 3
Adjust Thermostate
Fig. 4
Adjust Thermostat to “0”
Fig. 5
Press Button - No Light - Off
Fig. 1
Turn Engine Key to ON
Fig. 6
Turn Engine Key to OFF