5. INSTALLATION
When first installed
, or after a long time of inactivity, connect just the water suction hose
for a couple of
minutes to enable any impurities to be removed from the high-pressure hose.
WIRING CONNECTION
Check if the grid is the same for the high-pressure
cleaner tension, reported on the identification plate
(fig.3 pag.5).
Be sure that the tension provided is an
“earth” connection and a safety switch.
FUEL SUPPLY
Fill the fuel tank with combustible as reported on the identification plate (Diese
l) (see fig.5).
WATER CONNECTION
Connect the water feeling hose (pos. 1) to the entrance nipple (pos.2). See fig.6 on page 9.
It is recommended to use a reinforced hose with an
internal diameter of 10mm at least. The water inlet
must be of 15lt/min. at least
and must not have a temperature in the entry above
60°C
Fig.5
Connect the high-pressure hose (pos.3 fig.6) to the gun (pos.4) and with the other end of the
high-pressure hose to the o
utlet nipple (pos.5) locking
it in firmly.
Fig.6