WARNING 

1.  Never operate Petrol or Diesel Engine driven unit in explosive 

atmosphere, near combustible materials or where insufficient 
ventilation exists. 

2.  Ensure pump is on secure footing & level surface   
3.  Observe all safety precautions for the handling of fuel. 
4.  Never fill the engine while it is running, or after long periods of 

operation 

– let it cool for 30 minutes – Then Re-fuel 

5.  Use genuine replacement parts only. 
6.  Do not run pump dry. Always fill pump body with liquid to be 
7.  Pumped before starting the pump. 

PREPARATION FOR OPERATION

 

1. 

Inspect unit for shipping damage immediately upon receipt. If 
any visible damage exists note damage on shipping docket 
before signing. Notify your Distributor immediately of any 
damage to the shipment. 

2.  Read these instructions and power unit instructions until you 

are sure you can operate it safely and correctly. If in doubt as 
your supervisor 

3.  Before starting, fill crank-case with oil specified by engine 
4. 

Manufacturer (normally SAE 30) to the level marked on engine 
Indicator.   

5. 

Fuel - Use only Diesel fuel or unleaded gasoline for Petrol 
engines. 

6. 

Suction piping. Make sure packing is placed at the seat of 
hose coupling and all suction piping lines are perfectly free 
from air leaks. Make certain suction line is laid gradually 
descending from the pump to source of supply to avoid 
possibility of air lock. 

7.  Always fit strainer to end of suction line. Non return valve is 

always helpful but not essential. 

8.  Do not over tighten hose couplings. 
9. 

Arrange check valve, stop cock or on/off nozzle at delivery 
hose end. 

 

OPERATION 

1.  Remove filling cap from top of delivery outlet, fill casing with fresh 

water and refit cap. 

2. 

Open gate valve on delivery line.

 

3.  Open fuel cock, close engine choke, start engine, 
4.  NB. PA Fast prime pumps are self priming and no additional 

priming is required as long as the casing is filled with water and 
there are no suction line leaks. 

SHUT DOWN PROCEDURE 

1.  Slow engine then switch to off 'Stop' button. 
2.  Close fuel cock. 
3.  Drain pump casing if there is any possibility of freezing, 

PUMP OPERATING POINTERS 

1.  Never run pump dry as this may result in seal damage. 
2.  Ensure that all hose and pipe connections are airtight, 

IMPORTANT; an air leak in the suction line will prevent 
priming and will reduce the capacity of the pump. 

3.  Always place the pump as close to the liquid to be pumped as 

possible. Keep all lines as short and straight as possible, Avoid 
sharp bends in hoses. Keep the pump on a level foundation. 

4.  If flexible hose is laid across a roadway protect it with planking, 

Instantaneous shut off pressure is applied when a vehicle runs 
across an unprotected hose and will cause 'hydraulic shock'. 
This can damage and or breakage of pump casing of the 
pump and/or the hose. 

5.  When pumping dirty water or other liquids which may contain 

solids always use a pump strainer. If the suction strainer is 
likely to clog with dirt and debris do one of the following: 

 

(a) Prepare a bed of stones in which to rest the strainer. 
(b) Tie the strainer so that it stays at the bottom of the pit or 
excavation.   
(c)  Tie the strainer inside a basket or bucket to protect it from 
slurry, 

6.  Always flush out the pump at the end of operation if the liquid 

being pumped may leave a solid or sticky residue, 

 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 

 
 
 
 
 

This Guide is compatible with the following 
models; 

 
WP Series 

– Water Transfer 

WP10, WP15, WP20, WP30, WP40, WP60   

HP Series 

– High Head Transfer 

HP15 & HP15Dual, HP20& HP20Dual, HP30 

SHP Series 

– Super High Head

 

SHP50, SHP80, SHP100 

WB Series 

– Trash Pumps

 

WB80, WB100 

RX Series 

– Trash Pumps

 

RX80, RX100 

DFT Series 

– Diesel Transfer 

DFT40,DFT50,DFT60   

Nitro Series 

– Chemical Transfer

 

Nitro 50, Nitro 80 

SU Series 

– Hydraulic Transfer

 

SU25, SU40, SU50, SU80, SU100 
 
 
 

 
 
 
 
 

               

 

 

Отзывы: