![pumpa BLUE LINE PFC505 Скачать руководство пользователя страница 22](http://html1.mh-extra.com/html/pumpa/blue-line-pfc505/blue-line-pfc505_original-instruction-manual_1625795022.webp)
EN
22
13 Troubleshooting
Possible problems:
1. The pump is not filling up
2. Low flow rate
3. Pump generates noise
4. Pump does not start
5. Motor generates noise but does not run
Possible problem
Cause
Solution
1
2
3
4
5
X
X
Air suction
Check the watertightness of joints
and seals
X
Poor cover tightness
Clean the cover and check the seals
X
X
Excessive suction height
Adjust the pump to the correct
height
X
X
X
Incorrect voltage
Check the voltage indicated on the
nameplate and the mains voltage
X
No water in pre-set filter
Fill the pre-set filter with water
X
Clogged filter
Clean the filter
X
X
Connection cross-sectional diameter
is smaller than required
Use a connection with the correct
cross-sectional size
X
Clogged outlet
Check the filter and delivery pipe
X
Incorrect pump connection
Connect the pump correctly
X
Impurities in the pump
Clean the pump and check the filter
X
No voltage
Reset the fuses
X
Blocked motor
Call technical support
Содержание BLUE LINE PFC505
Страница 24: ...CZ SK EN 24 16EU Prohl en o shod...