Puma PRO25 Скачать руководство пользователя страница 3

 

 

 

INSTRUCTIONS FOR USE 

Audiometric Booth 

 

Rev.3.0 

17/03/2022

 

 
 
 

PRO 25 rev. 03 user manual an installation            Puma s.r.l.  2022   all rights reserved  

Page 3 of 17 

 

Use and contraindications, notice 
 

•  The sound-proof booth can be used only for audiometric examinations or similar and not 
for other medical purposes with applied components (i.e. electrodes) to the patient. It is 
necessary having different specifications in this case. 
 
•  The booth must be used only by trained personnel. 
 
•  Man performing the test must always see the patient inside the booth. 
 
•  It is forbidden to smoke and to light any flame inside the booth. 
 
•  The wrong booth installation or the position near-by flammable materials disclaim all 
manufacturer responsibilities.  
 
 

PUMA srl disclaims any responsibility for misuse, incorrect re-installation or improper use of the 
booth. 

 
 
Warnings: 
 

Connect the booth to an adequate electrical implant and compliant with the norm CEI 64-8; the 
plug must be inserted in a 230V electrical socket, protected against overload and short circuit 
and with differential switch. 
 
 
The silent booth cannot be installed in places classified with "explosion hazard" (EN 60079-10-1 
and EN 60079-10-2) and in rooms "used for medical use" classified as group 2 (CEI 64-8 
standard / 710 art. 710.2.7). 
 
Installation is permitted in "ordinary" rooms and in "medical" rooms classified as group 1 (CEI 
64-8 / 710 art. 710.2.6); the power supply must happen with an automatic switch with a 
sensitivity differential of 30 mA of "type AC", 230V. 
 
Please note that the environmental electrical system must comply with the law. 

 
 
notice 
 

According to the regulation EU 2017/745, annex 1, section III, paragraph 23.4, we advise you to 
report any incident related to the use of  
the medical device both to the competent authority of the state in which it is used,  
and to us as manufacturers at the following address: [email protected] 

 
 
 
 
 
 
 

Содержание PRO25

Страница 1: ...Rev 3 0 17 03 2022 PRO 25 rev 03 user manual an installation Puma s r l 2022 all rights reserved Page 1 of 17 User manual and installation Audiometric booth PRO25 Compliant with regulation EU 2017 745...

Страница 2: ...audiology centers and industrial environments Equipped with reversible door with magnetic closure universal cable passage external folding table for instruments and lighting Washable and sanitizable i...

Страница 3: ...ings Connect the booth to an adequate electrical implant and compliant with the norm CEI 64 8 the plug must be inserted in a 230V electrical socket protected against overload and short circuit and wit...

Страница 4: ...tions or type jack connections Fast replacement of equipment with different connections The ability to add cables throurgh Mounting 1 Remove the lid seals acting on the two screws by rotating with All...

Страница 5: ...cables fully insulated allowing an immediate connection with the main audiometric instruments between the inside and the outside of the cabin To be used with the universal connection panels Jack panel...

Страница 6: ...imensions and it is suitable for small spaces inside and outside the booth It s supported by two folding shelves and can be easily opened Easily opening device extending to the rail end The safety joi...

Страница 7: ...ance value with reference to what is stated by the IEC 64 710 the medical room systems should be regularly checked by a trained technician For this reason you should performs the following checks meas...

Страница 8: ...r electrified parts Request the assistance of qualified personnel The replacement of power fuses can be performed only by trained or expert personnel In case of power fuse replacement the rated curren...

Страница 9: ...Assembling the booth please follow carefully the drawings Read all instructions before beginning The screws and the Allen key as well are provided Use screws and Allen key provided Replacement of the...

Страница 10: ...INSTRUCTIONS FOR USE Audiometric Booth Rev 3 0 17 03 2022 PRO 25 rev 03 user manual an installation Puma s r l 2022 all rights reserved Page 10 of 17 Standard floor with adjustable feet...

Страница 11: ...ric Booth Rev 3 0 17 03 2022 PRO 25 rev 03 user manual an installation Puma s r l 2022 all rights reserved Page 11 of 17 Basement with castors optional BRAKE CONTROL Lift up to unlock Push to block Lo...

Страница 12: ...INSTRUCTIONS FOR USE Audiometric Booth Rev 3 0 17 03 2022 PRO 25 rev 03 user manual an installation Puma s r l 2022 all rights reserved Page 12 of 17...

Страница 13: ...INSTRUCTIONS FOR USE Audiometric Booth Rev 3 0 17 03 2022 PRO 25 rev 03 user manual an installation Puma s r l 2022 all rights reserved Page 13 of 17...

Страница 14: ...INSTRUCTIONS FOR USE Audiometric Booth Rev 3 0 17 03 2022 PRO 25 rev 03 user manual an installation Puma s r l 2022 all rights reserved Page 14 of 17...

Страница 15: ...an installation Puma s r l 2022 all rights reserved Page 15 of 17 Security stickers At the end of the operation apply the warning stickers as follows place the ATTENTION TO THE STEP and PUSH symbols...

Страница 16: ...INSTRUCTIONS FOR USE Audiometric Booth Rev 3 0 17 03 2022 PRO 25 rev 03 user manual an installation Puma s r l 2022 all rights reserved Page 16 of 17 Hooks for headphones internally...

Страница 17: ...all rights reserved Page 17 of 17 Electrical implant connection only for booths WITHOUT ventilation THIS OPERATION MUST BE CARRIED OUT BY QUALIFIED STAFF PUMA srl declines all responsibility for the...