1

 

Wrist device 

1.1

 

Power off/on 

The device is turned on by pressing the button firmly once for one second. The device will vibrate 
when it is ready to use.  

The device can be turned off (and rebooted) by pressing the button down for 10 seconds. The 
display will show a power off warning at first during which you can still release the button without 
powering off the device. 

Holding the button down for over eight seconds will start the device in the DFU mode and 
the display will stay dark. In this case, the device should be turned off and back on again 
with a shorter press. 

For the off-hand detection to work properly, the device should 

not be

 worn when turning it 

on. 

1.2

 

Positioning of the device 

When wearing the device, position the device approximately one finger width up the arm from the 
wrist bone. If possible, prefer the non-dominant hand as this will increase the quality of the data. 

 

 

1.3

 

Low battery/charging 

The device has a screen showing remaining battery. Currently no warning for low battery exists. 

The device can be recharged using a normal USB cable. When connecting the device to a charger, it 
will vibrate and display a recharging screen. Removing the device from the charger will also cause 
the device to vibrate. 

1.4

 

Usage modes 

The device has two modes: the sampled mode and the continuous mode. During the sampled mode, 
the device measures the heart rate every 5 minutes or whenever the button is pressed. 

Содержание SP-2D-W

Страница 1: ...PulseOn OHR Tracker User Instructions SP 2D W Firmware version 1 0 1 Application version 1 0 5 21 6 2018 PulseOn Oy...

Страница 2: ...date 5 2 4 Using the app 6 2 5 Recording raw data and streaming PPG 7 3 Data transfer and storing 9 3 1 Exporting the database as a CSV file 9 4 Data column explanations 11 4 1 ContinuousData table 11...

Страница 3: ...operly the device should not be worn when turning it on 1 2 Positioning of the device When wearing the device position the device approximately one finger width up the arm from the wrist bone If possi...

Страница 4: ...s The screen can be cycled through by pressing the button for one second for every new screen 1 4 1 1 Sampled mode Steps taken since starting the device Calories burned since starting the device Batte...

Страница 5: ...ess the files on the phone and to access the location These are required for the Bluetooth connection to work 2 2 Connecting to a device Starting the app it should display an empty screen with a SCAN...

Страница 6: ...usually already in the DFU mode and does not need to be restarted before proceeding 2 4 Using the app After a connection is established a screen like the following should appear The HR calories and st...

Страница 7: ...ton on the bottom of the screen and restarting the app 2 5 Recording raw data and streaming PPG To record raw data you will need to enable raw data collection From the extra menu press Continuous mode...

Страница 8: ...device should remain still and in a constant lighting When the PPG display is open no data will be written into the phone s database While this will not cause data loss in a longer run it will slow d...

Страница 9: ...accessing the SD card is open in the background Please close all file explorers etc while using the PulseOn recorder app The database is being written whenever there is a connection and transferrable...

Страница 10: ...es the user might want to delete the database after exporting to avoid having the same data in multiple exports The CSV files include the headers and all the data from the database and each field is s...

Страница 11: ...eps cumulative walking steps since turning on the device run_steps cumulative running steps since turning on the device bike_steps cumulative biking steps since turning on the device walk_distance cum...

Страница 12: ...ing the transfer of the file containing this line savetime time according to the phone when the file was transferred 4 3 ADL table Column Explanation timestamp milliseconds from 01 01 1970 Unix epoch...

Страница 13: ...g this line savetime time according to the phone when the file was transferred 4 5 AdlStatistics table This table exists but is set to be empty Column Explanation timestamp milliseconds from 01 01 197...

Страница 14: ...CAUTION RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS No user replaceable parts inside refer servicing to manufacturer specified...

Страница 15: ...o provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accorda...

Отзывы: