   Mounting Methods

Rev.00

The Pulsarlube EX is tested and certified by UL (USA), ATEX (Europe), and KCs (Korea). 

Explosion Hazard - Do not remove or replace batteries unless power has been 

disconnected or the area is known to be free of ignitable concentrations of 

flammable gases or vapors.

Replace Battery With Pulsarlube EX’s battery pack only.  Use of Another Battery May Present A  

    risk of Fire or Explosion. See Owner’s Manual For Safety Instructions.

        Warning

Shelf life and Warranty Product  

Warranty is limited to original defects in material and

workmanship and will not cover any collateral damage due to mishandling, abuse and /or any

other inappropriate use of this product. Warranty period is 1 year from the date of purchase.

(125& 250ml)

Series

User Manual

    Shelf life and Warranty

  LCD Functions

Selecting the dispensing period

Reset the unit when the unit 

malfunctions and/or after changing 

the Service Pack

Power 

ON/OFF

Press the button for 2 seconds

to turn unit 

on

 of 

off

.

Deactivate 'Automatic Lock Out' 

mode by pressing the button for 

2~3 seconds

  LCD Displays

The dispensing period setting

The unit is in 

"Automatic Lock Out" mode

Excessive backpressure exists

Selected grease pouch capacity 

Empty grease level

MONTH

The # of days remaining until the 

end of lube cycle

Low battery power

The test mode is activated 

Signal lamp blinks periodically 

when battery power is low, 

excessive backpressure exists, 

or if grease level is empty

/

The # of days after dispensing   

has completed

The       of days after the unit 

has stopped dispensing due to 

excessive backpressure

A) 

To select grease capacity

      A short press of the button to     

      select 125ml or 250ml capacity

 

B) 

To run a test cycle 

     Hold the button for 2 seconds

Pulsarlube U.S.A

TEL:1-847-593-5300  FAX:1-847-593-5303  www.pulsarlube.com / [email protected]

1480 Howard Street, Elk Grove Village, IL 60007, USA

Single Point Installation  

Direct Mount or Remote Installation using 

Extension Tube

Direct mount is always preferable.  
For applications not allowing any direct 
mounts, remotely mount the unit using 
appropriate accessories and keep the distance 
from the lube point as short as possible.

For remote installation using a tube, use a 
6mm O.D. (1/4") tubing pre-filled with the same 
or compatible grease as the grease contained 
in the unit. 

                    Reference Designation                    Description                    Type of Protection                    

M1

SW4

Motor

Reed Switch

Non-incendive Circuit
Non-incendive Circuit

This equipment is suitable for use in Class I, Division 2, Group C and D hazardous

locations. 

( SUBSTITUTION OF MOTOR AND REED SWITCH MAY IMPAIR SUITABILITY FOR 

DIVISION 2 )