Table 5. Mechanical parameters
Dimensions
W=280, H=291, D+D
1
=82+8 [+/- 2mm]
W
1
=285, H
1
=295 [+/- 2mm]
The dimensions of the battery
compartment
170 x 110 x 65mm (WxHxD) max
Gross/Net weight
2,7 / 2,9 kg
Enclosure
Steel plate, DC01 1,0mm color white RAL 9003
Closing
Cheese head screw x 2 (at the front), (lock assembly possible)
Connectors
Power supply of the cameras: RJ45 socket
Input 230VAC:
Φ 0,63-2,50 (AWG 22-10)
Battery output BAT: 6,3F-2,5
TAMPER output: wires
Notes
The enclosure does not touch the assembly surface so that cables can be led.
Table 6. Operation safety
Protection class PN-EN 609501:2007
I (first)
Protection grade PN-EN 60529: 2002 (U)
IP20
Electrical strength of insulation:
- between input and output circuits of the PSU (I/P-O/P)
- between input circuit and PE protection circuit (I/P-FG)
- between output circuit and PE protection circuit (O/P-FG)
3000 V/AC min.
1500 V/AC min.
500 V/AC min.
Insulation resistance:
- between input circuit and output or protection circuit
100 MΩ, 500V/DC
Declarations, warranty
CE, 2 year from the production date
Table 7. Operating parameters
Operating temperature
-
10ºC...+40ºC
Storage temperature
-
20ºC...+60ºC
Relative humidity
20%...90%, without condensation
Vibrations during operation
unacceptable
Impulse waves during operation
unacceptable
Direct insulation
unacceptable
Vibrations and impulse waves during transport
According to PN-83/T-42106
2. Installation
2.1. Installation procedure
The device should be mounted by a qualified installer, holding relevant permits and licenses (applicable and required for
a given country) for 230V/AC and low-voltage installations.
The device shall be mounted in confined spaces, according to the environment class II, with normal air humidity
(RH=90% max. without condensation) and the temperature from -
10°C to +40°C.
The switch shall work in a vertical position that guarantees sufficient convectional air-flow through ventilating holes of the
enclosure.
Before installation, prepare a Switch'a load balance.
The given value of 30W per port is the maximum value referring to a single output. The total power consumption
should not exceed 48W when all PoE ports are being used
. The increased demand for power is particularly evident in the
case of cameras with heaters or infrared illuminators - when launching these features, the power consumption increases rapidly,
which may adversely affect the operation of the switch. As the device is designed for a continuous operation and is not
equipped with a power-switch, therefore an appropriate overload protection shall be guaranteed in the power supply circuit.
Moreover, the user shall be informed about the method of unplugging (usually through assigning an appropriate fuse in the fuse-
box). The electrical system shall follow valid standards and regulations.
2.2. Installation procedure
1. Before installation, cut off the voltage in the 230V power-supply circuit.
2. Mount the PSU in a selected location and connect the wires.
3. Connect the power cables (~230VAC) to L-N clips of the PSU.
The shock protection circuit shall be performed with a particular care, i.e. the yellow
and green wire coat of the power cable shall stick to one side of the terminal - marked
with ‘
‘
symbol on the PSU enclosure. Operation of the PSU without the properly
made and fully operational shock protection circuit is UNACCEPTABLE! It can cause a
device failure or an electric shock.
4. Connect the ground wire to the terminal marked with the
symbol (power supply module connector). Connect the
ground wire to the clip marked by the earth symbol PE. Use a three-core cable (with a yellow and green PE protection
wire) to make the connection. Lead the cables to the appropriate clips through the insulating bushing of the connection
board.