background image

 

Table 5. Mechanical parameters 

Dimensions 

W=280, H=291, D+D

1

=82+8 [+/- 2mm] 

W

1

=285, H

1

=295 [+/- 2mm] 

The dimensions of the battery 
compartment 

170 x 110 x 65mm (WxHxD) max 

Gross/Net weight 

2,7 / 2,9 kg 

Enclosure 

Steel plate, DC01 1,0mm color white RAL 9003 

Closing 

Cheese head screw x 2 (at the front), (lock assembly possible) 

Connectors 

Power supply of the cameras:  RJ45 socket 
Input 230VAC: 

Φ 0,63-2,50 (AWG 22-10)  

Battery output BAT: 6,3F-2,5  
TAMPER output: wires  

Notes 

The enclosure does not touch the assembly surface so that cables can be led. 

 
Table 6. Operation safety 

Protection class PN-EN 609501:2007  

I (first) 

Protection grade PN-EN 60529: 2002 (U)  

IP20 

Electrical strength of insulation: 
- between input and output circuits of the PSU (I/P-O/P) 
- between input circuit and PE protection circuit (I/P-FG) 
- between output circuit and PE protection circuit (O/P-FG) 

 

3000 V/AC min. 
1500 V/AC min. 
  500 V/AC min. 

Insulation resistance: 
- between input circuit and output or protection circuit 

 

100 MΩ, 500V/DC 

Declarations, warranty 

 

CE, 2 year from the production date

 

 

Table 7. Operating parameters

 

Operating temperature 

-

10ºC...+40ºC 

Storage temperature 

-

20ºC...+60ºC 

Relative humidity 

20%...90%, without condensation 

Vibrations during operation 

unacceptable 

Impulse waves during operation 

unacceptable 

Direct insulation 

unacceptable 

Vibrations and impulse waves during transport 

According to PN-83/T-42106 

 

2.  Installation 

2.1. Installation procedure 

The device should be mounted by a qualified installer, holding relevant permits and licenses (applicable and  required  for  

a  given  country)  for  230V/AC  and  low-voltage  installations.  

The  device  shall  be  mounted  in  confined  spaces,  according  to  the  environment  class  II,  with  normal  air  humidity 

(RH=90% max. without condensation) and the temperature from -

10°C to +40°C.  

The  switch  shall  work  in  a  vertical  position  that  guarantees  sufficient  convectional  air-flow  through  ventilating  holes  of  the 
enclosure.  

Before installation, prepare a Switch'a load balance.  

 
The given value of 30W per port is the maximum value referring to a single output. The total power consumption 

should not exceed 48W when all PoE ports are being used

. The increased demand for power is particularly evident in the 

case of cameras with heaters or infrared illuminators - when launching these features, the power consumption increases rapidly, 
which  may  adversely  affect  the  operation  of  the  switch.  As  the  device  is  designed  for  a  continuous  operation  and  is  not 
equipped  with  a  power-switch,  therefore  an  appropriate  overload  protection  shall  be  guaranteed  in  the  power  supply  circuit. 
Moreover, the user shall be informed about the method of unplugging (usually through assigning an appropriate fuse in the fuse-
box). The electrical system shall follow valid standards and regulations. 
 

2.2.  Installation procedure 

1. Before installation, cut off the voltage in the 230V power-supply circuit. 
2. Mount the PSU in a selected location and connect the wires.  
3. Connect the power cables (~230VAC) to L-N clips of the PSU.  
 

 

The shock protection circuit shall be performed with a particular care, i.e. the yellow 

and green wire coat of the power cable shall stick to one side of the terminal - marked 

with ‘

 symbol on the PSU enclosure. Operation of the PSU without the properly 

made and fully operational shock protection circuit is UNACCEPTABLE! It can cause a 

device failure or an electric shock. 

4. Connect the ground wire to the terminal marked with the 

 symbol (power supply module connector). Connect the 

ground wire to the clip marked by the earth symbol PE. Use a three-core cable (with a yellow and green PE protection 
wire) to make the connection. Lead the cables to the appropriate clips through the insulating bushing of the connection 
board.  
 

Содержание SG64-B

Страница 1: ...re color white RAL 9003 with battery space for a 7Ah 12V battery Supports auto learning and auto aging of MAC addresses 1K size warranty 2 year from the production date Example of use CONTENTS 1 Techn...

Страница 2: ...up time assumptions for calculations Automatic detection of any devices powered in the PoE PoE standard is enabled at the 1 4 ports of the switch The UP LINK ports is used for connection of another ne...

Страница 3: ...witch PoE 2 Switch mode buffer power supply unit 3 DC DC52115 converter 4 Output filter 5 Tamper micro switch terminals of tamper protection NC 6 Battery space for a 7Ah 12V 7 Power supply connector o...

Страница 4: ...ct PoE Status The given value of 30W per port is the maximum value The total power consumption should not exceed 48W when all PoE ports are being used Table 4 Electrical parameters Mains supply 176 26...

Страница 5: ...10 C to 40 C The switch shall work in a vertical position that guarantees sufficient convectional air flow through ventilating holes of the enclosure Before installation prepare a Switch a load balan...

Страница 6: ...onnector 8 Check the optical indication of the switch operation 9 After installing and checking proper working the enclosure can be closed Connection schemes 3 Indication of the device operation 3 1 L...

Страница 7: ...IEEE802 3af at standard ON supply at the RJ45 port Blinking short circuit or output overload YELLOW LED LIGHT LINK The connection status of LAN devices 10MB s or 100Mb s and data transmission OFF no c...

Страница 8: ...work The PSU does not require performing any specific maintenance measures however in case of significant dust rate its interior is recommended to be cleaned with compressed air In case of fuse replac...

Отзывы: