6
The shock protection circuit shall be performed with a particular care, i.e. the yellow and green wire coat of the
power cable shall stick to one side of the terminal -
marked with ‘
‘ symbol on the PSU enclosure. Operation
of the PSU without the properly made and fully operational shock protection circuit is UNACCEPTABLE! It can
cause a device failure or an electric shock.
4. Connect the ground wire to the terminal marked with the
symbol (power supply module connector). Connect
the ground wire to the clip marked by the earth symbol
. Use a three-core cable (with a yellow and green
protection wire) to make the connection. Lead the cables to the appropriate clips through the insulating bushing of
the connection board.
5. Connect the power (230 V).
6. Connect the battery (mind the colours):
- battery output (+V): BAT+ cable / red,
- battery output (0V): BAT
– cable / GND / black.
7. Connect the camera cables to the RJ45 connectors (PoE connectors) and connect the recorder to the network
(the UP LINK connector).
8. Check the optical indication of the switch operation.
9. After installing and checking proper working, the enclosure can be closed.
Connection schemes