background image

 

 

       

Table 2. 

            

Ports 

5  10/100Mb/s ports (4 x PoE + 1 x UPLINK)                                                                                              

with connection speed auto-negotiation and MDI/MDIX Auto Cross) 

PoE power supply 

IEEE 802.3af (1

÷4 ports),  48VDC / 15,4W at each port *   

Protocols, Standards 

IEEE802.3, 802.3u, 802.3x  CSMA/CD, TCP/IP 

Forwarding rate 

10BASE-T: 14880pps/port 

100BASE-TX: 148800pps/port 

Bandwidth 

1,6Gbps 

Transmission method 

Store-and-Forward 

Optical indication of 
operation 

Switch power supply; 

Link/Act; 

PoE Status 

Power supply 

90 ÷ 264VAC 50÷60Hz / 1,2A  230VAC 

the PSD 480125 48VDC / 1,25A/60W max. power supply desktop type 

Operating conditions 

temperature -

10°C ÷ 45°C,  

relative humidity  5% - 90%, no condensation 

Dimensions (W x H x D) 

118 x 28 x 85 [mm] 

Additional equipment 

plate to be fixed surface 

Net/gross weight 

0,54/ 0,78kg 

Protection class        
EN 60950-1:2007 

II (second) 

Storage temperatur 

-

20°C ÷ 60°C 

Declarations 

CE 

  * The given value of 15.4W per port is the maximum value. The total power consumption should not exceed 48W when all PoE ports are being used. 

 

2.  Installation 

 

                2.1. Requirements 

              The unit should be mounted in confined spaces, in accordance with the 2nd environmental class, with normal relative 
humidity (RH=90% maximum, without condensation) and temperature from -

10°C to +45°C. Ensure the free flow of air around 

the unit. The PSU shall work in a vertical position that guarantees sufficient convectional air-flow through ventilating holes of the 
enclosure.  

The load balance should be done before installation Switcha. The given value of 15.4W per port is the maximum value 

referring to a single output. The total power consumption should not exceed 48W when all PoE ports are being used. 
The  increased  demand  for  power  is  particularly  evident  in  the  case  of  cameras  with  heaters  or  infrared  illuminators  -    when 
launching these features, the power consumption increases rapidly, which may adversely affect the operation of the switch. The 
device  is  designed  for  a  continuous  operation  and  is  not  equipped  with  a  power-switch.  Therefore,  an  appropriate  overload 
protection  in  the  power  supply  circuit  should  be  provided.  The  electrical  system  shall  be  made  in  accordance  with  applicable 
standards and regulations.   

 

               2.2.  Installation procedure 

1. Connect switch to the PSD480125 48VDC power supply unit desktop type.    

 

2. Connect the power supply to the AC 230V socket. 
3. Connect the camera wires to the RJ45 connectors (PoE connectors). 
4. Check the optical indication of switch operation (see Table 3). 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание S54

Страница 1: ... date Example of use 1 Technical description 1 1 General description S54 is a 5 port PoE switch designed to supply IP cameras operating in IEEE 802 3af standard Automatic detection of any devices powered in the PoE standard is enabled at the 1 4 ports of the switch The UPLINK port is used for connection of another network device The LEDs at the front panel indicate the operation status description...

Страница 2: ... diagram 1 3 Description of components and connectors Table 1 see Fig 2 Element no Fig 2 Description 1 4 x PoE port 1 4 2 1 x UPLINK port 3 Power Socket of the 48VDC Fig 2 The view switch a 1 4 Technical parameters ...

Страница 3: ...h normal relative humidity RH 90 maximum without condensation and temperature from 10 C to 45 C Ensure the free flow of air around the unit The PSU shall work in a vertical position that guarantees sufficient convectional air flow through ventilating holes of the enclosure The load balance should be done before installation Switcha The given value of 15 4W per port is the maximum value referring t...

Страница 4: ...4 Connection schemes ...

Страница 5: ...r not compliant with the IEEE802 3af standard ON supply at the RJ45 port Blinking short circuit or output overload YELLOW LED LIGHT LINK The connection status of LAN devices 10MB s or 100Mb s and data transmission OFF no connection ON the device is connected 10Mb s or 100Mb s Blinking data transmission OPTICAL INDICATION AT THE UPLINK PORT GREEN LED LIGHT OFF no connection ON the device is connect...

Страница 6: ...ossibilities to carry out the repairs or if the equipment has been conditionally accepted due to the breaking warranty terms by the claimant 7 All the services are carried out at the service centre of the manufacturer exclusively 8 The warranty does not cover the defects of the equipment resulting from reasons beyond the manufacturer s control mechanical damage improper storage and transport use t...

Отзывы: