background image

 

          Table 2. (See Fig.3) 

Component No. 

(Fig. 3) 

Description 

[1] 

4 x PoE port (1

÷4) 

[2] 

1 x UPLINK port 

[3] 

48VDC power supply socket 

 

 

 

Fig. 3 The view switch'a. 

 
 
 
 
 
 

 
 

1.4. Technical parameters (Table 3.) 
 

       

Table 3. 

            

Ports 

5  10/100Mb/s ports (4 x PoE + 1 x UPLINK)                                                                                              

with connection speed auto-negotiation and MDI/MDIX Auto Cross) 

PoE power supply 

IEEE 802.3af (1

÷4 ports),  48VDC / 15,4W at each port *  

Protocols, Standards 

IEEE802.3, 802.3u, 802.3x  CSMA/CD, TCP/IP 

Forwarding rate 

10BASE-T: 14880pps/port 

100BASE-TX: 148800pps/port 

Bandwidth 

1,6Gbps 

Transmission method 

Store-and-Forward 

Optical indication of 
operation 

Switch power supply; 

Link/Act; 

PoE Status 

Power supply 

90 ÷ 264VAC 50÷60Hz / 1,2A  230VAC 

Operating conditions 

temperature -

10°C ÷ 45°C,  

relative humidity  5% - 90%, no condensation 

Dimensions (W x H x D) 

Switch: 118 x 28 x 85 [mm] 

Enclosure: 540 x 440 x 110+14  [mm] 

Enclosure 

Steel plate, DC01 1,0mm color white RAL 9003 

Closing 

Cheese screw x 2 (at the front) (lock assembly possible) 

Notes 

The enclosure does not adjoin the assembly surface so that cables can be led 

Gross/Net weight 

7,15/7,84kg 

Protection class        
EN 60950-1:2007 

II (second) 

Storage temperatur 

-

20°C ÷ 60°C 

Declarations 

CE 

* The given value of 15.4W per port is the maximum value. The total power consumption should not exceed 48W when all PoE ports are being used. 
 
 
 
 
 

 

 

Содержание S54-CR

Страница 1: ...03 warranty 2 year from the production date Example of use 1 Technical description 1 1 General description The S54 CR is a complete kit to build the CCTV system based on IP cameras The switch is placed in a metal enclosure with recorder space Automatic detection of any devices powered in the PoE standard is enabled at the 1 4 ports of the switch The UPLINK port is used for connection of another ne...

Страница 2: ...ntiometer adjusting the output voltage of the power supply 46 52V 4 LED light power supply operation indication 5 F 6 3A 250V fuse socket 6 Mounting brackets for cables 7 Space for the 48VDC 1 2A 60W power supply of the recorder desktop type 8 Power Socket of the 230V AC recorder 9 Recorder space of dimensions max 400x345x100mm WxHxD 10 Straps for attaching the DVR in enclosure Fig 2 The enclosure...

Страница 3: ...ard Optical indication of operation Switch power supply Link Act PoE Status Power supply 90 264VAC 50 60Hz 1 2A 230VAC Operating conditions temperature 10 C 45 C relative humidity 5 90 no condensation Dimensions W x H x D Switch 118 x 28 x 85 mm Enclosure 540 x 440 x 110 14 mm Enclosure Steel plate DC01 1 0mm color white RAL 9003 Closing Cheese screw x 2 at the front lock assembly possible Notes T...

Страница 4: ...f the switch The device is designed for a continuous operation and is not equipped with a power switch Therefore an appropriate overload protection in the power supply circuit should be provided Moreover the user should be informed how to disconnect the power supply unit from the mains supply usually by assigning an appropriate fuse in the fuse box The electrical system shall be made in accordance...

Страница 5: ...cted or not compliant with the IEEE802 3af standard ON supply at the RJ45 port Blinking short circuit or output overload YELLOW LED LIGHT LINK The connection status of LAN devices 10MB s or 100Mb s and data transmission OFF no connection ON the device is connected 10Mb s or 100Mb s Blinking data transmission OPTICAL INDICATION AT THE UPLINK PORT GREEN LED LIGHT OFF no connection ON the device is c...

Страница 6: ...ossibilities to carry out the repairs or if the equipment has been conditionally accepted due to the breaking warranty terms by the claimant 7 All the services are carried out at the service centre of the manufacturer exclusively 8 The warranty does not cover the defects of the equipment resulting from reasons beyond the manufacturer s control mechanical damage improper storage and transport use t...

Отзывы: