background image

 

 

S108-CRB

 

v1.2 

S108-CRB 10-ports switch with buffer power supply 

for 8 IP cameras and recorder in recorder space 

 

 

                                                                                                                                                 

 

        PL 

               

    Edition: 3 from 14.02.2019  

                   Supercedes the edition: 2 from 02.07.2018                  

 EN**

 

 

 

 

Features

 

 

Uninterruptible power supply of 8 IP cameras (52 V DC) 

 

Uninterruptible power supply of the recorder (12 V DC)  

 

10 ports 10/100 Mb/s 
8 PoE ports 10/100Mb/s, (data and power supply) 
2 ports 10/100Mb/s (UpLink)       

 

30 W for each PoE port, supports devices complaint with 
the IEEE802.3af/at 

(PoE+)

 standard  

 

Supports auto-learning and auto-aging of MAC addresses 
(1K size) 

 

Approximate backup time: 3h 15min 
 

 

LED indication 

 

Metal enclosure 

– color white RAL 9003 

with space for two 17 Ah/12V  battery and 
offers the possibility of recorder installation 

 

The enclosure construction is compliant 
with the requirements of the General 
Data Protection Regulation GDPR (the 
possibility of installing two locks with 
different codes)

 

 

Space for a recorder with the following 
dimensions 380x320x65 (WxHxD) 

 

warranty 

– 2 year from the production date 

          

Example of use. 

 

     CONTENTS 

1. Technical description.  

1.1 General description 
1.2 Block diagram 
1.3 Description of components and connectors  
1.4 Technical parameters 

2. Installation.  

2.1 Requirements  
2.2 Installation procedure 

3. Indication of the device operation 

3.1 LED indication of operating status 
3.2 Optical indication of the switch operation 

4. Operation and use.  

4.1 Overload or short circuit of the PSU output (SCP on)  
4.2 Disconnection of discharged battery 
4.3 Maintenance 

Содержание S108-CRB

Страница 1: ...space for two 17 Ah 12V battery and offers the possibility of recorder installation The enclosure construction is compliant with the requirements of the General Data Protection Regulation GDPR the possibility of installing two locks with different codes Space for a recorder with the following dimensions 380x320x65 WxHxD warranty 2 year from the production date Example of use CONTENTS 1 Technical d...

Страница 2: ...es The electricity consumption for own needs and the energy efficiency of the power intake track were taken into account The exact description of how to perform the calculations can be found at Approximate backup time assumptions for calculations Automatic detection of any devices powered in the PoE PoE standard is enabled at the 1 8 ports of the switch The Up Link ports is used for connection of ...

Страница 3: ... converter 4 DC DC50SD converter 5 Output filter 6 Tamper micro switch terminals of tamper protection NC 7 Battery space for two 2 x 17Ah 12V connect the batteries in series 8 Space for a recorder 380x320x65 WxHxD 9 Power supply connector of the PSU L N Protective connector electric shock 10 BAT BAT battery output BAT red BAT black 11 DVR power cord terminated with the DC 2 1 5 5 plug ...

Страница 4: ...Transmission method Store and Forward Optical indication of operation Switch power supply Link Act PoE Status The given value of 30 W per port is the maximum value The total power consumption should not exceed 120 W Table 4 Electrical parameters Mains supply 200 240 V 50 Hz Current up to 1 3 A Supply power 208 W Output current at the PoE ports RJ45 8 x 0 6 A ΣI 2 3 A max Output voltage at the PoE ...

Страница 5: ...n between input and output circuits of the PSU between input circuit and protection circuit between output circuit and protection circuit 3000 V AC min 1500 V AC min 500 V AC min Insulation resistance between input circuit and output or protection circuit 100 MΩ 500 V DC Declarations CE Table 7 Operating parameters Operating temperature 10ºC 40ºC Storage temperature 20ºC 60ºC Relative humidity 20 ...

Страница 6: ...d connect the wires 2 Connect the power cables 230 V to L N clips of the PSU The shock protection circuit shall be performed with a particular care i e the yellow and green wire coat of the power cable shall stick to one side of the terminal marked with symbol on the PSU enclosure Operation of the PSU without the properly made and fully operational shock protection circuit is UNACCEPTABLE It can c...

Страница 7: ...rts OFF no power supply at the RJ45 port the device is not connected or not compliant with the IEEE802 3af at standard ON supply at the RJ45 port Blinking short circuit or output overload YELLOW LED LIGHT LINK The connection status of LAN devices 10 100Mb s and data transmission OFF no connection ON the device is connected 10 100Mb s Blinking data transmission OPTICAL INDICATION AT THE UPLINK PORT...

Страница 8: ...e disconnection of the PSU from the power supply network The PSU does not require performing any specific maintenance measures however in case of significant dust rate its interior is recommended to be cleaned with compressed air In case of fuse replacement use a replacement of the same parameters WEEE LABEL Waste electrical and electronic equipment must not be disposed of with normal household wa...

Отзывы: