Pulsar RSUPS54R Скачать руководство пользователя страница 5

www.pulsar.pl

    

 

 

 

RSUPS54R 

 

 

 

            

RACK POWER 

 

 

 

Fig.4. The view of the switch. 

 

Table 2. (See Fig. 3). 

Element no. 

 [Fig. 4] 

Description 

 

LINK

 - yellow LED - indicating the LAN connection status 

 

PoE

 - green LED indicating voltage at the PoE port

 

 

PWR 

– green LED indicating the supply voltage of the Switch

 

 

UPLINK 

port for recorder (data)

 

 

PoE 

port

 

1÷4  

for cameras IP connection (data + power supply)

 

 
1.4.  Specifications. 

- parameters of the switch (tab.3) 
- electrical parameters (tab.4) 
- mechanical parameters (tab.5) 
- operation safety (tab.6) 
- operating parameters (tab.7)

 

 Parameters of the switch (tab. 3). 

Ports 

5 10/100Mb/s ports (4 x PoE + 1 x UPLINK)                                                                                              
with connection speed auto-negotiation and MDI/MDIX Auto Cross) 

PoE power supply 

IEEE 802.3af (1

÷4 ports),  48VDC / 15,4W at each port *  

Protocols, Standards 

IEEE802.3, 802.3u, 802.3x  CSMA/CD, TCP/IP 

Forwarding rate 

10BASE-T: 14880pps/port 
100BASE-TX: 148800pps/port 

Bandwidth 

1,6Gbps 

Transmission 
method 

Store-and-Forward 

Optical  indication  of 
operation 

Switch power supply; 
Link/Act; 
PoE Status 

*

 

The given value of 15,4W per port is the maximum value. The total power consumption should not exceed 48W when all PoE ports are 

being used. 

 Electrical parameters (tab. 4). 

Mains supply 

176÷264V AC  

Current up to 

1,1A@230V AC max. 

Supply power 

122W max. 

Output voltage at the PoE ports 
 
Output voltage the recorder 

– NVR 

48V DC 

– maintained regardless of the state of battery charge 

 
12V DC 

– maintained regardless of the state of battery charge 

The output current at the PoE ports  

4 x 0,3A Ʃ=1A (max.) 

Output current of the recorder 

– NVR 

5A 

Ripple voltage 

– output of the NVR recorder 

150 mV p-p max. 

Battery charge current 

0,5A max. (+/-5%) 

Short-circuit protection SCP and overload 
protection OLP  

105% ÷ 150% of the PSU power, manual restart (failure 
requires the disconnection of the DC output) 

Battery circuit protection SCP and reverse 
polarity connection 

melting fuse 

PSU current consumption 

0,2A 

Excessive discharge protection UVP 

U<19V (+/-5%) 

– disconnect of connection battery 

Optical indication of operation: 

LED: AC, DC, NVR, TEMP, LoB, ALARM, LINK, PoE 

Acoustic operation indication: 

Piezoelectric indicator ~75dB/0,3m 

The ALARM technical output of collective failure 

Relay type: 1A@ 30VDC/50VAC 

The 

F

MAINS

 

fuse in the 230V power supply circuit 

T 3,15A 

Содержание RSUPS54R

Страница 1: ...RSUPS54R v 1 0 5 port switch for 4 IP cameras IP with battery backup for cameras and recorder RACK mounted EN Edition 1 from 28 06 2016 Supercedes the edition ...

Страница 2: ...ata transfer and power supply 15 4W for each PoE port supports devices complaint with the IEEE802 3af standard Supports auto learning and auto aging of MAC addresses 1K size wide range of mains supply AC 176 264V AC battery charging and maintenance control excessive discharging UVP protection battery output protection against short circuit and reverse connection battery charge current 0 5A voltage...

Страница 3: ...t panel indicate the operating status of the device The switch is fitted with the ALARM technical output of collective failure In the case of failure a LED light is activated which is accompanied by switching of relay contacts and acoustic indication The PoE technology ensures a network connection and reduces installation costs by eliminating the need to supply a separate power cable for each devi...

Страница 4: ... in the top position indication ON switch in the down position indication OFF PoE port 1 4 for cameras IP connection data power supply UPLINK port for recorder data 230V AC INPUT power socket 230V AC power cable 1 5m included FMAINS fuse in the supply circuit 230V AC T 3 15A 250V Fig 2 The front power of the power supply unit Fig 3 The view of the PSU ...

Страница 5: ... 15 4W per port is the maximum value The total power consumption should not exceed 48W when all PoE ports are being used Electrical parameters tab 4 Mains supply 176 264V AC Current up to 1 1A 230V AC max Supply power 122W max Output voltage at the PoE ports Output voltage the recorder NVR 48V DC maintained regardless of the state of battery charge 12V DC maintained regardless of the state of batt...

Страница 6: ...out condensation Vibrations during operation unacceptable Impulse waves during operation unacceptable Direct insulation unacceptable Vibrations and impulse waves during transport According to PN 83 T 42106 2 Installation 2 1 Requirements The PSU RACK shall be mounted by a qualified installer with appropriate permissions and qualifications for 230V AC installations and low voltage installations req...

Страница 7: ...f the DVR by default the device is equipped with a cable terminated with the DC 2 1 5 5 plug 7 Make the following technical connections when needed ALARM technical output of collective failure indication 8 Check the optical indication of the switch operation 3 Indication of the device operation 3 1 LED indication of operating status The PSU has 6 LED lights at the front panel GREEN LED on the PSU ...

Страница 8: ...ted 10Mb s or 100Mb s YELLOW LED LIGHT LINK The connection status of LAN devices 10MB s or 100Mb s and data transmission OFF no data transmission ON the device is connected 10Mb s or 100Mb s Blinking data transmission 3 3 Technical output The power supply is fitted with the ALARM output of collective failure relay type A collective failure can be triggered by the following events 230V AC mains pow...

Страница 9: ...outage the device is immediately switched into a battery assisted operation The PSU is equipped with the discharged battery disconnection system During the battery assisted operation reducing voltage below 19V at the battery terminals will cause battery disconnection 4 3 Maintenance Any and all maintenance operations may be performed following the disconnection of the PSU from the power supply net...

Страница 10: ...he manufacturer 6 The repair period mentioned in point 5 may be prolonged if there are no technical possibilities to carry out the repairs or if the equipment has been conditionally accepted due to the breaking warranty terms by the claimant 7 All the services are carried out at the service centre of the manufacturer exclusively 8 The warranty does not cover the defects of the equipment resulting ...