background image

 

 

 

1.4. Technical parameters (Table 3.) 
 

Table 3. 

Ports 

9  10/100Mb/s ports (4 x PoE + 1 x UPLINK)                                                                                              

with connection speed auto-negotiation and MDI/MDIX Auto Cross) 

PoE power supply 

IEEE 802.3af (1

÷4 ports),  48V DC / 15,4W at each port *  

Protocols, Standards 

IEEE802.3, 802.3u, 802.3x  CSMA/CD, TCP/IP 

Forwarding rate 

10BASE-T: 14880pps/port 

100BASE-TX: 148800pps/port 

Bandwidth 

1,6Gbps 

Transmission method 

Store-and-Forward 

Optical indication of 
operation 

Switch power supply; 

Link/Act; 

PoE Status 

Power supply 

90 

÷ 264VAC 50÷60Hz / 1,2A  230VAC 

Operating conditions 

temperature -

10°C ÷ 45°C,  

relative humidity  5% - 90%, no condensation 

Dimensions (W x H x D) 

 

440 x 44,5 x 230 [mm] 

Enclosure 

RACK 19″ 1U Steel plate, DC01 1,0mm color RAL 9005 

Gross/Net weight 

2,2/ 2,4kg 

Protection class        
EN 60950-1:2007 

II (

second

)

 

Storage temperatur 

-

20°C ÷ 60°C 

Declarations 

CE 

 
* The given value of 15.4W per port is the maximum value. The total power consumption should not exceed 48W when all PoE ports are being used. 

2.  Installation 

2.1. Installation procedure 

1.  The unit should be mounted by a qualified installer, holding relevant permits and licenses (applicable and 

required for a given country) for 230V/AC interference and low-voltage installations.  

2.  The unit should be mounted in confined spaces, in accordance with the 2nd environmental class, with normal 

relative humidity (RH=90% maximum, without condensation) and temperature from -

10°C to +45°C.  

3.  The switch shall operate in a horizontal position in order to ensure free air convection in the RACK cabinet. The 

switch load balance should be done prior to installation.  
The given value of 15,4W per port is the maximum value referring to a single output. The total power 
consumption should not exceed 48W when all PoE ports are being used. 
The increased demand for power is particularly evident in the case of cameras with heaters or infrared 
illuminators - when launching these features, the power consumption increases rapidly, which may adversely 
affect the operation of the switch. 
The device is designed for a continuous operation and is not equipped with a power-switch. Therefore, an 
appropriate overload protection in the power supply circuit should be provided. Moreover, the user should be 
informed how to disconnect the power supply unit from the mains supply (usually by assigning an appropriate 
fuse in the fuse box). The electrical system shall be made in accordance with applicable standards and 
regulations.  

 

2.2.  Installation procedure 

1.  Mount the switch in a RACK 19 

” cabinet 

             2.   Connect the plug of the power supply switch to the AC 230V socket.  

 Make sure that the device is installed in such a manner and place, that the free flow of air around the device      
is ensured. 

            3.   Connect the power (~230V).  
            4.   Connect the camera wires to the RJ45 connectors (PoE connectors). 
            5.   Check the optical indication of the switch operation. 
        

 

               
 
 
 
 
 
 
 

Содержание RS94

Страница 1: ...escription The RS94 is a 9 port switch in a RACK 19 metal housing with integrated power supply Automatic detection of any devices powered in the PoE standard is enabled at the 1 4 ports of the switch Ports 5 to 8 are LAN ports network devices not requiring the PoE power supply can be connected to them The UPLINK port is used for connection of another network device The LEDs at the front panel indi...

Страница 2: ...Description of components and connectors Table 1 see Fig 2 Element no Fig 2 Description 1 4 x PoE port 1 4 2 4 x PoE port 5 8 3 1 x UPLINK port 4 Switch mode power supply for the switch 48VDC 1 2A 60W 5 230V AC power cord Fig 2 The enclosure view ...

Страница 3: ...ive humidity RH 90 maximum without condensation and temperature from 10 C to 45 C 3 The switch shall operate in a horizontal position in order to ensure free air convection in the RACK cabinet The switch load balance should be done prior to installation The given value of 15 4W per port is the maximum value referring to a single output The total power consumption should not exceed 48W when all PoE...

Страница 4: ...4 Connection schemes ...

Страница 5: ...he device is connected 10Mb s or 100Mb s Blinking data transmission OPTICAL INDICATION AT THE LAN PORTS 5 8 DIODA LED ZIELONA PoE Indication of the PoE power supply at the RJ45 ports OFF no power supply at the RJ45 port the device is not connected or not compliant with the IEEE802 3af standard ON supply at the RJ45 port Blinking short circuit or output overload YELLOW LED LIGHT LINK The connection...

Страница 6: ...ossibilities to carry out the repairs or if the equipment has been conditionally accepted due to the breaking warranty terms by the claimant 7 All the services are carried out at the service centre of the manufacturer exclusively 8 The warranty does not cover the defects of the equipment resulting from reasons beyond the manufacturer s control mechanical damage improper storage and transport use t...

Отзывы: