1. Technical description. 
 

1.1  General description. 

             The 

PSDC04124

  stabilized  power  supply  is  designed  to  supply  HD  cameras  or  other  devices  requiring 

stabilized voltage of 

12V DC

. The output voltage adjustment range is adjusted via a potentiometer within the range 

of 

12V÷15V  DC.

  The  PSU  features  4  outputs  protected  independently  by  either  glass  fuses  or  polymer  fuse.  A 

failure  (a  short  circuit)  in  the  output  circuit  makes  a  fuse  blow  or  an  activation  of  the  polymer  fuse  and 
disconnection  of  the  circuit  from  the  DC  power  supply  (+U).  The  PSU  is  housed  in  a  metallic  enclosure  with  an 
indication panel featuring a microswitch indicating unwanted opening of the door (faceplate).  
 

1.2. Block diagram (fig.1). 

 

 

Fig.1. Block diagram of the PSU. 

 

1.3. Description of PSU components and connectors. 
 

Table 1.  Elements of the PSU PCB (see fig. 2). 

Element no. 

Description 

[1] 

L1…L4 

 (green) LEDs  (indicating fuse activation) 

[2] 

F1…F4 

glass fuses in AUX (+) circuits 

[3] 

IN  

supply input of the LB4/AW strip 

[4] 

AUX1…AUX4 

outputs, 

COM 

(-) shared terminal 

[5] 

L

FPS

 

(red)

 

diode indicating failure of a particular output (fuse activation) 

[6] 

FPS  

output indicating failure of a particular output, OC type 

(normal status: L, failure: hi-Z)

 

[7] 

Jumper for the selection of the fuse type: 

Fx Fx.x

 Fx jumper on – glass fuse    

Fx Fx.x

 Fx.x jumper off – polymer fuse

 

Содержание PSDC 04124

Страница 1: ...PSDC 04124 v 1 3 PSDC 12V 4A 4x1A Power supply for up to 4 HD cameras PTC TOPIC EN Edition 12 from 11 10 2017 Supersedes the edition 11 from 24 04 2017...

Страница 2: ...P over voltage protection surge protection OLP overload protection against tampering warranty 3 year from the production date Example of power supply of up 4 HD cameras All channels adjustable in the...

Страница 3: ...The PSU is housed in a metallic enclosure with an indication panel featuring a microswitch indicating unwanted opening of the door faceplate 1 2 Block diagram fig 1 Fig 1 Block diagram of the PSU 1 3...

Страница 4: ...s PE protection connector 2 F fuse in the power supply circuit 230V AC 3 PSU module 4 VADJ potentiometer output voltage adjustment within the range of 12V 15V DC 5 LED indication of DC power status ma...

Страница 5: ...se failure blow of LB4 AW strips SCP activation OC type 50mA max normal status L level 0V failure hi Z level F1 F4 fuses F 1A 250V or PTC 1A manual selection Mechanical specifications tab 4 Dimensions...

Страница 6: ...PSU in a selected location and connect the wires 3 Connect the power cables 230VAC to L N terminals of the PSU Connect the ground wire to the terminal marked by the earth symbol Use a three core cabl...

Страница 7: ...output indicating unwanted opening of the PSU contains volt free potential free contacts indicating the door status unit closed NC unit opened NO 4 Operation and use 4 1 Overload or short circuit at t...

Страница 8: ...s required not to dispose of electric or electronic waste as unsorted municipal waste and to collect such WEEE separately Pulsar Siedlec 150 32 744 apczyca Poland Tel 48 14 610 19 40 Fax 48 14 610 19...

Отзывы: