Pulsar PSCU 04344SEP Скачать руководство пользователя страница 6

www.pulsar.pl                                                     PSCU 04344SEP                                                                     

 

 

 

Typical distances between the power supply and the DCDC converter (Table 7): 

 

Cable type: 

Cross-

section 

[mm

2

According 

to AWG 

The distance between the PSCU04344 power supply unit 

and the DC/DC converter: 

Current consumption of the 

camera: 0,8A/12VDC 

Current consumption of the 

camera: 1,2A/12VDC 

UTP5e twisted pair cable, 
one pc 

0,2mm

2

 

24AWG 

100 m 

60 m 

UTP5e twisted pair cable, 
2 pcs 

0,4mm

2

 

21AWG 

200 m 

120 m 

UTP5e twisted pair cable, 
3 pcs 

0,6mm

2

 

19AWG 

300 m 

180 m 

Stranded cable

 

0,25mm

2

 

23AWG 

100 m 

75m 

Stranded cable 

0,5mm

2

 

20AWG 

250 m 

150m 

Stranded cable 

0,75mm

2

 

18AWG 

400 m 

240m 

Stranded cable 

1,0mm

2

 

17AWG 

500 m 

300m 

Stranded cable 

1,5mm

2

 

15AWG 

700 m 

400m 

The distances are given for the rated voltage of Un=230Vac and 

Ta=20°C. 

 
3. Optical indication. 

 

The  PSU  is  fitted  with  4  green 

L1÷L4  LEDs  at  the  PCB,  indicating  DC  voltage  at  the  AUX1÷AUX4  outputs. 

During normal operation, the LED is permanently illuminated. In case of short-circuit or output overload, the LED is 
off. 

 
4. Service and operation. 

 
4.1  Overload or short-circuit of the power supply output (SCP activation). 

The 

AUX1÷AUX4  outputs  of  the  PSU  are  individually  protected  against  short-circuit  by

 

melting  fuses.  In 

case of fuse replacement, use only compatible replacement parts. If the output load current exceeds 

Σ4,0A@30 V 

DC (110% ÷ 150% of the S power), the F fuse in the 230 V AC circuit and/or F1÷F4 fuses become permanently 
damaged. In case of failure, replace the fuse with the same type. 

 

4.2 Maintenance. 

All  maintenance  procedures  can  be  performed  after  disconnecting  the  power  supply  from  the  power 

network.  The  PSU  does  not  require  any  specific  maintenance;  however,  its  interior  should  be  cleaned  with 
compressed air if used in dusty conditions. In case of fuse replacement, use only compatible replacement parts 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

Содержание PSCU 04344SEP

Страница 1: ...PSCU 04344SEP v 1 0 PSCU 34VDC 4A 4x1A SEP DC power supply for CCTV EN Edition 2 from 07 10 2014 Supersedes the edition 1 from 10 06 2014...

Страница 2: ...ion 4 1 Overload or short circuit of the power supply output 4 2 Maintenance 1 Technical description 1 1 General description The PSCU04344SEP power supply unit is designed for supply of CCTV devices T...

Страница 3: ...es in the AUX1 AUX4 output circuits L1 L4 LEDs indicating voltage at the individual outputs AUX1 AUX4 independently protected outputs Fig 2 The view of the LP4 SEP strip Tab 2 Components of the PSU se...

Страница 4: ...U I P O P between input circuit and PE protection circuit I P FG between output circuit and PE protection circuit O P FG 3000 V AC min 1500 V AC min 500 V AC min Insulation resistance between input ci...

Страница 5: ...k protection circuit shall be done with a particular care the yellow and green wire coat of the power cable should be connected to the terminal marked with the PE symbol Operation of the PSU without t...

Страница 6: ...tted with 4 green L1 L4 LEDs at the PCB indicating DC voltage at the AUX1 AUX4 outputs During normal operation the LED is permanently illuminated In case of short circuit or output overload the LED is...

Страница 7: ...e repair period mentioned in item 5 may be prolonged if there are no technical possibilities to carry out the repairs or if the equipment has been conditionally accepted due to the breaking warranty t...

Страница 8: ...ww pulsar pl PSCU 04344SEP 8 Pulsar K Bogusz Sp j Siedlec 150 32 744 apczyca Poland Phone 48 14 610 19 40 Fax 48 14 610 19 50 E mail biuro pulsar pl sales pulsar pl http www pulsar pl www zasilacze pl...