1.4. Technical parameters:  

- electrical parameters (tab.3) 
- mechanical parameters (tab.4) 
- operation safety (tab.5) 
- operation parameters (tab.6)

 

 

      Electrical parameters (tab. 3). 

Supply voltage 

230V AC (-15%/+10%) 

Supply frequency 

50Hz 

PSU power P 

138W  

Current consumption  

1.1A  

Output voltage 

11.0V ÷ 13.8V DC – buffer operation 
10.0V ÷ 13.8V DC – battery operation 

Output voltage setting, escalation and keeping 
time 

20ms / 30ms / 50ms 
 

Voltage setting range 

12.5V ÷ 14.2VDC  

Pulsating voltage  

50mV p-p max. 

Output current  

1 x 10A – main AUX- or 
3 x 2.5A - outputs: +AUX1-, +AUX2-, +AUX3- 

Power consumption of the power-supply unit 
systems during battery operation 

20mA max. 

Battery charging current 

0.7A / 2.1A / 3.6A / 4.8A 

SCP short-circuit protection  

200% ÷ 250% of power supply,  
hiccup mode – 13A/200ms and/or  
fuse failure in the battery circuit (fuse-element 
replacement required) 

OLP overload protection  

110% ÷ 150% of power supply – electronic. 
Disconnection of power supply outputs – automatic re-
connection after the disconnecting of the DC output 
circuit 

SCP protection of the battery circuit and reverse 
polarity protection 

10A - current limitation, F1 fuse (failure requires 
replace of the fuse-element) 

UVP excessive discharge protection  

U < 10.0 V (± 5%)  

Technical outputs: 
- BS output indicating failure of AC power supply 
- AW output indicating failure (activation of SCP, 
OLP, UVP, converter failure) 
 
- TAMPER output indicating the opening of the 
power supply casing 

 
- OC type, 50mA max, normal status: hi-Z level, failure: 
level L (0V), 30s time lag. 
- OC type, 50mA max, normal status: L(0V) level, 
failure: hi-Z level, (automatic return after correct 
operation is returned) 
- micro-switch x2, NC contacts (closed casing, 
mounted on foundation), 0.5A@50V DC (max) 

F1 fuse 
F2 fuse 

F 10A / 250V 
T 6.3A / 250V  

      

Mechanical parameters (tab 4). 

Casing dimensions 

350 x 425 x 180  (345 x 420 x 172+8) (WxHxD) [mm] (+/- 2) 

Fixation 

315 x 390 x Φ 6   x 4szt (WxH)   

Battery space 

40Ah/12V (SLA) max.  

Net/gross weight 

10.40 / 11.10 kg 

Casing colour 

RAL 9003 

Closing 

Cheese screw x 2 (at the front), lock assembly possible 

Connectors 

Power-supply: Φ0.41-2.5 
Outputs: Ф0.41÷2.5 
BAT battery outputs: connectors Φ6 (M6-0-2.5) 
TAMPER output: wires, 300 mm 

Notes 

The casing is distant from the assembly surface so that cables can be 
installed, cooling: natural convection 

       

Содержание PSBD 10A12

Страница 1: ...PSU B 13 8V S 10A 1 EL TR 40Ah MC PSBD 10A12 v 1 0 Buffer switch mode power supply unit EN Edition 2 from 27 th October 2010 Supercedes edition 1 from 27 th May 2010...

Страница 2: ...e 3 The power supply operation indication 3 1 Optical indication 3 2 Technical output 4 Service and operation 4 1 Overload or short circuit 4 2 Battery operation 4 3 Maintenance 1 Technical descriptio...

Страница 3: ...3 1 2 Block diagram fig 1 Fig 1 Block diagram of the power supply unit...

Страница 4: ...ply operation 7 AC LED diode that indicates the presence of AC voltage 8 LB LED diode that indicates battery charging 9 OVP LED diode that indicates the activation of the OVP overvoltage protection 10...

Страница 5: ...t 1 Separation transformer 2 Power supply unit board tab 1 3 TAMPER micro switch contacts of the anti sabotage protection NC 4 F2 fuse in the power supply circuit 230VAC 5 L N 230VAC power supply conn...

Страница 6: ...6 Fig 3 View of the power supply unit...

Страница 7: ...otection of the battery circuit and reverse polarity protection 10A current limitation F1 fuse failure requires replace of the fuse element UVP excessive discharge protection U 10 0 V 5 Technical outp...

Страница 8: ...rrents collected by receivers shall not exceed I 10A P 138W max including the maximum battery charging current Ibat As the power supply is designed for a continuous operation and is not equipped with...

Страница 9: ...reover the PSU is equipped with three diodes indicating operation status AC LB AUX O1 O2 O3 and UVP placed on the PCB of the power supply unit module AC red diode under normal status AC supply the dio...

Страница 10: ...the fuse F1 in the battery circuit becomes permanently damaged The restoration of the voltage at the BAT output requires the replacement of the fuse 4 2 Battery operation In the case of power failure...

Страница 11: ...ing of the equipment to the service centre of the manufacturer 7 The repair period mentioned in item 5 may be prolonged if there is no technical capability to carry out the repairs and in the case tha...

Отзывы: