background image

www.pulsar.pl 

PSAC04244SEP 

   

 

 

1.4. Specifications: 
- electrical specifications (tab.3) 
- mechanical specifications (tab.4) 
- operation safety (tab.5) 
- operating specifications (tab.6) 

       
       Electrical specifications (table 3). 

Mains supply 

230V AC  (-15%/+10%) 

Current consumption 

0,5 A max.  

Power frequency 

50 Hz  

PSU power  

100VA max. 

Output voltage 

U1 : 23,0÷28,0V AC (100% load ÷ 0% load) 
U2 : 25,5÷31,5V AC (100% load ÷ 0% load) 

Voltage setting range 

U1/U2  (jumper selectable) 

Output current  

4x 1A  

Σ

4,0A@24V AC max or 

4x0,9A 

Σ

3,7A@27V AC max  

Short-circuit protection SCP 

4x F 1,0A glass or   PTC 1A  
-  glass fuse damage requires fuse-element replacement 

Overload protection OLP 

AC 24V circuit : 4x F 1,0A or PTC 1A  (jumper selectable) 
AC 230V circuit : 1x T 1,0A  

Overvoltage protection 

varistors 

Overheat protection OHP 

yes- transformer 

Tampering protection: 
- TAMPER output indicating enclosure 
opening 

- microswitch, NC connectors (closed casing), 
0.5A@50V DC (max.) 

Technical outputs: 
- AW output indicating failure of one of 
the AUX outputs (fuse activation) 
 

 
relay type, 1A@ 30V DC/50V AC max. 
Caution!! In Fig.2. the set of contacts indicates potential-free 
status which corresponds to  power supply failure. 

LED indication: 
LED L1÷L4 (green) 
 
LED L

AW

 (red) 

- status of OUT1 ÷ OUT4  
normal status = illuminated, failure status = not illuminated 
- failure indication of min. one output 
normal status = not illuminated, failure status = illuminated 

F

MAIN 

f

 

use 

F1÷F4 fuses 

T 1A/ 250V 
F 1A/ 250V or PTC 1A   

       Mechanical specifications (table 4). 

Enclosure dimensions 

210 x 241 x 64 (215 x 246 x 56+8)   (WxHxD) 

Fixing 

178 x 211  4x 

Φ

6   

Net/gross weight 

2,70/2,90 kg 

Enclosure 

Steel plate DC01  0,7mm thick, colour RAL9003 

Closing 

Cheese head screw (at the front) 

Connectors 

Supply: 

Φ

0.63÷2.50 (AWG 22-10) 

Outputs: 

Ф

0.41÷1.63 (AWG 26-14) 

TAMPER output: cables of 25cm 

Notes 

The casing is equipped with distance from the mounting basis in order to guide 
the wiring system, convection cooling. 

       Operation safety (table5). 

PN-EN 60950-1:2007 protection class 

I (first) 

PN-EN 60529: 2002 (U) protection grade 

IP20 

Electrical strength of insulation: 
-  between  the  input  (network)  circuit  and  output  circuits  of  the  power 
supply (I/P-O/P) 
- between the input circuit and the PE protective circuit (I/P-FG) 
- between the output circuit and the PE protective circuit (O/P-FG) 

 
 
3000V AC min. 
1500V AC min. 
500V AC min. 

Insulation resistance: 
- between the input circuit and the output or protective circuit 

 
100 M

, 500 V DC  

 

Содержание PSAC 04244SEP

Страница 1: ...PSAC 04244SEP v 1 0 PSAC 24VAC 4A 4x1A SEP AC power supply for CCTV EN Edition 2nd 05 Jul 2012 Supersedes the 1st 1 from 06 Dec 2011 edition...

Страница 2: ...of PSU components and connectors 1 4 Specifications 2 Installation 2 1 Requirements 2 2 Installation procedure 3 Operating status indication 3 1 LED indication 3 2 Technical output 4 Operation and us...

Страница 3: ...g 2 the set of contacts indicates potential free status which corresponds to power supply failure 7 Jumper based fuse selection glass fuse or polymer fuse Fx Fx x Fx jumper on glass fuse selected Fx F...

Страница 4: ...www pulsar pl PSAC04244SEP 4 Fig 3 View of the PSU s panel Fig 4 The view of the power supply...

Страница 5: ...l free status which corresponds to power supply failure LED indication LED L1 L4 green LED LAW red status of OUT1 OUT4 normal status illuminated failure status not illuminated failure indication of mi...

Страница 6: ...cted location and connect the wires 3 Connect the power cables 230V AC with L N power supply terminals Connect the ground wire to the terminal marked by the earth symbol Use a three core cable with a...

Страница 7: ...tion and use 4 1 Overload or short circuit at the PSU output The OUT1 OUT4 outputs are protected against a short circuit with glass or polymer fuses In case of fuse damage the replacement of the same...

Страница 8: ...ccepted due to the breaking warranty terms by the claimant 7 All the services rendered by force of the warranty are carried out at the service centre of the manufacturer exclusively 8 The warranty doe...

Отзывы: