2.2 Installation procedure. 

 

1). Before installation, make sure that the voltage in the 230V power-supply circuit is cut off. 

2). Mount the PSU in a selected location and connect the wires. 
3). Connect the power cables to the L-N terminals. Connect the ground wire to the terminal marked by the earth symbol 

– 

”. Use a three-core cable (with a yellow and green PE protection wire) to make the connection. Lead the cables to the 

appropriate terminals of the connection board through the bushing. 
 

 

 
The shock protection circuit shall be performed with a particular care, i.e. the yellow and green 

wire  coat  of  the  power  cable  shall  stick  to  one  side  of  the  terminal  marked  with  the  '

'  earth 

symbol in the PSU enclosure. Operation of the power supply without a properly made and fully 
operational  shock  protection  circuit  is  UNACCEPTABLE!  It  can  result  in  device  damage  or  an 
electric shock. 

 

 
4). 

Connect the receivers’ cables to the AUXx- COM connectors of the terminal block on the LB4/24V/27V/AW pcb. 

5). 

If necessary, connect the devices’ wires (alarm panel, controller, indicator, etc.) to the PSU’s technical outputs:   

     - 

FPS 

output indicating fuse activation (output of the LB4/24V/27V/AW strip) 

     - 

TAMPER 

output indicating unwanted opening of the PSU enclosure 

6). In case of installation where significant voltage drops occur in the resistance of the cables leading to the receivers, 
there is a possibility of  (step) voltage value correction by the U1/U2 jumpers. Adjustment in the output voltage value 24V 
AC/27V AC is independent for each AUX output. 
7). Restore the mains power ~230 V AC. 
8). Check the LED indication for PSU operating status: LEDs L1

÷L4 (green) should be constantly illuminated. 

9). Once the installation and operation control have been completed, the enclosure can be locked. 

      
 3. Operating status indication. 

The PSU is equipped with LED indication of operation status. The presence of power at the outputs of the PSU  is 

indicated by the illumination of green LEDs on the PCB of the LB4/24V/27V/AW strip (module). A failure is indicated by a 
red LED 

[!] L

FPS

. The PSU status can be remotely controlled through the FPS technical output.  

 

3.1 LED indication. 

 

L

1….L4

 green LEDs indicate power at the outputs: 

AUX1…..AUX4. 

In  case  of  a  power  loss  at  the  output  (fuse  burn/PTC  activation),  an  appropriate  diode  goes  out  (L1  for  AUX1,  L2  for 
AUX2 etc.). 

 

 

LED [!] L

FPS

 red diode indicates a failure at the at least one AUX output (output number is indicated by a green 

diode). 

 

3.2 Technical outputs. 

The PSU has some indication outputs that enable providing information about a failure or tampering. 

 

FPS

 

– output indicating a fuse failure (output of the LB4/24V/27V/AW strip). 

In a normal status (under proper operation), the FPS technical output is fault to ground (GND). When any of the 
fuses get damaged, the output is switched into hi-Z  - high impedance state. The failure status is also indicated 
by the L

FPS

 red diode. 

 

 

Fig. 5. Electrical diagram of OC output. 

 

 

TAMPER  - 

output  indicating  unwanted  opening  the  power-supply  unit,

 

volt-free  (potential-free)  contacts  in  the 

output indicate the door status, unit closed: NC, unit opened: NO 

 
 
 
 
 
 

 

Содержание PSAC 04244

Страница 1: ...PSAC 04244 v 1 1 PSAC 24VAC 4A 4x1A AC power supply for up to 4 analog cameras EN Edition 5 from 25 05 2015 Supersedes the edition 4 from 05 11 2014...

Страница 2: ...mponents and connectors 1 4 Specifications 2 Installation 2 1 Requirements 2 2 Installation procedure 3 Operating status indication 3 1 LED indication 3 2 Technical outputs 4 Operation and use 4 1 Ove...

Страница 3: ...wer input 4 AUX1 AUX4 outputs joint terminal COM 5 LFPS red LED indicating failure at one of the outputs fuse activation 6 FPS output indicating failure at one of the outputs OC type L normal state hi...

Страница 4: ...s of the PSAC 04244 power supply unit Element no Fig 4 Description 1 Isolation transformer 2 Fuse strip module LB4 24V 27V AW tab 1 3 TAMPER tampering connector NC 4 F fuse in the power supply circuit...

Страница 5: ...al specifications tab 3 Mains supply 230V AC 15 10 Current consumption 0 5 A max Power frequency 50 Hz Power of the S PSU 100VA max Output voltage U1 23 28V AC 100 load 0 load U2 25 5 31 5V AC 100 loa...

Страница 6: ...P between input circuit and PE protection circuit I P FG between output circuit and PE protection circuit O P FG 3000 V AC min 1500 V AC min 500 V AC min Insulation resistance between input circuit a...

Страница 7: ...U2 jumpers Adjustment in the output voltage value 24V AC 27V AC is independent for each AUX output 7 Restore the mains power 230 V AC 8 Check the LED indication for PSU operating status LEDs L1 L4 gre...

Страница 8: ...arranty applies to complete equipment accompanied by a properly filled warranty claim with a description of the defect 5 Should the claim be accepted the manufacturer is obliged to provide warranty re...

Отзывы: