WARRANTY

27

What this Warranty Does Not Cover:

Normal wear: This warranty excludes normal wear items such as filters, spark plugs, gaskets, O-rings, adapter cord

sets, wheels, and starting batteries.

Maintenance: This warranty does not apply to tune-ups or routine maintenance and does not cover any adjustments or

repairs not performed by an authorized repair facility.

Misuse: This warranty does not apply if your product has failed due to abuse, misuse, neglect, using incorrect fuels or

operated in any way contrary to the instructions found in the products owner’s manual.

damage claims to this product caused by shipment must be filed with freighter.

number has been removed. Refurbished, used, demonstration or floor models are not covered by this warranty.

lubricants, overloading, overspeeding, improper maintenance, improper storage, unapproved modifications, or has been

Adverse conditions:  This warranty does not apply if your product has failed due to freezing, accident or natural

disasters.

 Product shipment:  This warranty does not apply to damage resulting from shipping, handling, or warehousing. Any

Other exclusions: This warranty does not apply if your product has been sold “as is” or where the factory applied serial

Where Warranty is Valid:

For warranty coverage, this product must be purchased from an authorized Pulsar Products Inc. dealer and the warranty 

only extends to the original purchaser in the United States, Canada, or Mexico. Refurbished, used, demonstration, or floor 

models are not covered by this warranty. Products purchased from on-line auction websites, such as ebay, are not covered 

under this warranty. Products used for commercial use are not covered under this warranty.

How to Obtain Warranty Service:

Take the original receipt and product to the place of purchase or mail the original receipt and product to the address found 

on the web site if purchased on-line.  You can also locate your nearest Pulsar Products Inc. dealer for service or warranty 

questions by calling toll free at 1-866-591-8921.  Pulsar Products Inc. recommends you retain all of your receipts 

covering the purchase and maintenance of your Portable Generator, but will not deny you warranty coverage as long as 

proof of purchase or service can be obtained.

Pulsar Products Inc.’s obligation under this warranty is exclusively limited to product repair or replacement and 

shall not be liable for any incidental or consequential damages including, but not limited to, the expense of 

delivering product to and from a repair center, loss or damage to personal property, loss of revenue, telephone 

charges, loss of time, or inconvenience. Some states, provinces or jurisdictions do not allow the exclusion or 

limitation of incidental damages, so the above limitation may not apply to you. The warranty gives you specific 

legal rights, and you may also have other rights which vary from state to state or province to province.

Image of products may slightly differ due to continued improvement of product.

Rev.A 4/24/2017

Содержание PG5250B

Страница 1: ...www pulsar products com OPERATOR S MANUAL Warning The Engine Exhaust from this product contains chemicals known to the State of California to cause cancer birth defects or other reproductive harm Mode...

Страница 2: ...gine oil 11 Adding Fuel 12 Connecting Generator to an Electrical System 12 Operation 13 Grounding the Generator 13 How to Start Engine 13 How to Stop Engine 14 Receptacles and Extension Cords 15 Don t...

Страница 3: ...Specifications To order parts receive warranty assistance or other services inquiries you can contact us at www pulsar products com The emissions control system for this generator is compliant with al...

Страница 4: ...serious injury avoid attempting to lift the generator alone WARNING Safety Instructions Using a generator indoors WILL KILL YOU IN MINUTES Carbon monoxide gas is a poisonous odorless gas that can cau...

Страница 5: ...If unit has been running then the fuel cap is under pressure remove slowly To keep fuel from spilling secure unit so it cannot tip while operating or transporting When transporting unit disconnect the...

Страница 6: ...nerator on a level surface Always connect the nut and ground terminal on the frame to an appropriate ground source WARNING Generator must be properly grounded to prevent electrocution Never handle the...

Страница 7: ...eter C Circuit Protectors D Main Circuit Breaker E Voltage Selector F Two 120 V Receptacles G 30 Amp RV Receptacle H 120 240 Volt AC 30 Amp twist lock receptacle NEMA L14 30 I Ground Terminal J Fuel S...

Страница 8: ...nt L Fuel Gauge M Generator Frame N Choke Lever O Air Filter P Pull Start Q Handle R Support Foot S Fuel Cap T Gas Tank U Fuel Valve V Oil Fill Dipstick W Propane Inlet X No Flat Wheels FEATURES S T U...

Страница 9: ...ve generator on box to install wheel assembly Description Qty Handles Screw Nut 1 4 4 Wheels 2 Hair pin 2 Axles 2 Packing List Check all loose parts to the following list Contact your dealer if any lo...

Страница 10: ...using M8 screws 2 and nuts Installing Support Leg See fig 2 Parts needed 2 wheels 2 axles 2 hair pins and 2 washers Raise or tilt generator so you can slide the wheel axle pin into the wheel the washe...

Страница 11: ...dipstick hold and carefully add 4 Cycle engine oil SAE10W 30 to empty reservoir until oil reaches the outer edge of the oil fill hole crankcase dipstick hole Be sure to replace dipstick before attempt...

Страница 12: ...y or death to electric utility workers WARNING This generator produces a very high voltage which could result in burn or electrocution causing serious injury or death Connecting Generator to an Electr...

Страница 13: ...ion See fig 9 Turn the fuel selector to GAS position See fig 10 Slide the choke lever to the Choke position See fig 11 SKIP THIS IF THE ENGINE IS WARM OR HOT For manual start turn the engine START ON...

Страница 14: ...OPERATION 14 Fig 9 Fig 13 CHOKE RUN CHOKE LEVER CHOKE RUN CHOKE LEVER WAIT 5sec Fig 11 SKIP THIS IF THE ENGINE IS WARM OR HOT Fig 12 Recoil Start Fig 8 Fig 10 GAS PROPANE START...

Страница 15: ...rd This generator is equipped with the following receptacles How to Stop Engine See fig 14 17 All loads MUST be disconnected from the generator Never start or stop the engine with electrical devices p...

Страница 16: ...ple to lift Lift and lower with your legs by bending at the knees not your back to avoid injury Don t Overload Generator Make sure you can supply enough rated watts and surge watts for all electronic...

Страница 17: ...ic Blanket 400 400 Space Heater 1800 1800 Kitchen Blender 300 900 Toaster 2 slice 1000 1600 Coffee Maker 1500 1500 Electric Range 1 element 1500 1500 Dishwasher 1500 3000 Electric Oven 3410 3410 Elect...

Страница 18: ...lest output last to help prevent overloading the generator Allow generator output to stabilize engine and attached devices run evenly before plugging in the next load Fig 18 Cold Weather Operation Und...

Страница 19: ...sure the air filter is clean Remove any debris that has collected on the generator and around the muffler and controls Use a vacuum cleaner to pick up loose debris If dirt is caked on use a soft bris...

Страница 20: ...res determine the proper oil viscosity for the engine Use the chart to select the best viscosity for the outdoor temperature range expected Carefully add SAE 10W 30 to empty reservoir until the oil re...

Страница 21: ...Equivalent To clean remove the air filter cover Carefully pull the air filter out by lifting up along the edges Remove dirt from filter by tapping on it or having it blown out Replace with new filter...

Страница 22: ...close the fuel valve and reinstall fuel line securely on petcock Remove the fuel line that leads to the carburetor from the petcock by squeezing the ends of the hose clamps and sliding the fuel line...

Страница 23: ...owly pull the recoil Starter until you feel the engine build compression When you feel resistance Leave the Engine in this state as this will prevent any corrosion on the cylinder walls if stored for...

Страница 24: ...er in fuel 8 Fuel valve is in OFF position 9 Over choking 10 Low oil level 11 Rich fuel mixture 12 Intake valve stuck open or closed 13 Loss of engine compression 14 Dead battery 15 Engine has flooded...