CONTROL PANEL FUNCTIONS

Fuel Cap

Turn counterclockwise to remove the fuel cap.

Fuel Cap Air Vent

The fuel cap is equipped with an air vent to stop fuel from flowing to the 

carburetor. The Air Vent must be in the “ON” position to allow fuel to flow 

so that the engine can run. Turn the Air Vent to the “OFF” position to stop 

fuel flow.

Ground Terminal

This portable inverter generator is equipped with a terminal for the 

connection of a ground electrode conductor where a grounding electrode 

system is required by NEC Article 250.34(A). The equipment grounding 

conductors of the generator receptacles are bonded to the generator 

frame. Where the generator supplies power to cord and plug connected 

equipment, like power tools, the frame of the generator is not required by 

the NEC to be connected to an earthen ground electrode. The generator 

neutral conductor is bonded to the generator frame in accordance with 

NEC Article 250.34(C)

• Only operate generator on a level surface.

• Always connect the nut and ground terminal on the frame to an appropriate ground source.

WARNING!

Generator must be properly grounded to prevent electrocution.

ON

OFF

Note: 

The 

Economy

 switch must be turned to the “OFF” position when using electronic devices that require a large 

starting current, such as a compressor.

Parallel Outlets

Located just above the Ground Terminal, the generator’s Parallel Outlets enable a user to run two PG2300iS generator’s 

simultaneously. This operation requires special cables. When operating parallel generators, the rated output is 3.42kVA and the 

rated current is 30A/120VAC. For cables and instructions consult a PULSAR dealer for a PARALLEL OPERATION CABLE KIT.

• Only connect this generator to another PG2300iS

CO

 Standard Generator.

• Only use a parallel operation cable kit designed to work with this Generator. 

WARNING!

Never connect generators that are different models.

Содержание PG2300iSCO

Страница 1: ...Inverter Gasoline OPERATOR S MANUAL Model PG2300iSCO support pulsar products com...

Страница 2: ...l system 11 Adding Fuel 11 Adding Checking Oil 12 Operation 13 Grounding the Generator 13 How to Start Engine 13 How to Stop Engine 14 Attaching Electronic Devices 14 Charging a 12 Volt Battery 15 AC...

Страница 3: ...our generator will give you many years of reliable service Product Specifications This generator is an engine driven revolving field alternating current AC portable generator It is designed to supply...

Страница 4: ...te indoors or in a confined space that prevents dangerous carbon monoxide gas from dissipating Using a generator indoors CAN KILL YOU IN MINUTES Carbon monoxide gas is a poisonous odorless gas that ca...

Страница 5: ...and other flammable debris When adding or draining fuel unit should be turned off for at least 2 minutes to cool before removing fuel cap If unit has been running the fuel cap may be under pressure re...

Страница 6: ...quipment Only when operating at the preset governed speed this generator will supply the correct rated frequency and voltage WARNING Generator must be properly grounded to prevent electrocution Only o...

Страница 7: ...ter Q Parallel Outlets R Ground Terminal S Circuit Breaker AC T 12V DC Port U 12V DC 8A Circuit Breaker V CO Sensor Light CH O KE O FF I Control Panel J Oil Warning Light K Overload Indicator Light L...

Страница 8: ...ight If the engine overload indicator light comes on the generator s wattage amperage capacity has been exceeded by connected electrical devices or by a power surge When this occurs the green AC Pilot...

Страница 9: ...devices until the load is within the specified rated output To re establish power return the DC Circuit Breaker back to the ON position CAUTION If the DC Circuit Breaker turns off again stop using th...

Страница 10: ...or neutral conductor is bonded to the generator frame in accordance with NEC Article 250 34 C Only operate generator on a level surface Always connect the nut and ground terminal on the frame to an ap...

Страница 11: ...erator produces a very high voltage which could result in burn or electrocution causing serious injury or death Connecting Generator to an Electrical System If connecting generator to a building s ele...

Страница 12: ...ine Insert a funnel into the crankcase dipstick hole and carefully add the specified amount of 4 Cycle engine oil SAE 10W 30 to empty reservoir until or oil reaches the outer edge of the oil fill hole...

Страница 13: ...he ON position Turn the 3 in 1 Start Switch to CHOKE Pull recoil handle starter cord slowly until resistance is felt then pull rapidly Let engine run for several seconds and then gradually as engine w...

Страница 14: ...he fuel cap Air Vent to the OFF position How to Attach Electronic Devices 1 Before Starting generator Make sure the generator is grounded see page 10 for instructions Make sure the attached load is wi...

Страница 15: ...ur with a hydrometer to prevent overcharging and to test the battery s condition Be careful to follow the hydrometer manufacture s instruction Do not disconnect battery clamps while charging Batteries...

Страница 16: ...d or plug If an appliance begins to operate abnormally becomes sluggish or stalls turn off and disconnect appliance immediately The appliance may have a fault or its rated load capacity exceeds the po...

Страница 17: ...or 800 800 Laser Printer 250 950 Copy Machine 700 800 Power Tools 1000W Quartz Halogen Work Light 1000 1000 Airless Sprayer HP 600 800 Reciprocating Saw 750 950 Circular Saw 7 1400 2300 Miter Saw 10 8...

Страница 18: ...e debris If dirt is caked on use a soft bristle brush Inspect the work area for hazards After Each Use Follow the following procedure after each use Shut off engine Store unit in a clean and dry area...

Страница 19: ...n access to the spark plug Disconnect the spark plug wire from the spark plug Before removing the spark plug clean the area around its base to prevent debris from entering the engine Insert a 19mm 6 p...

Страница 20: ...nerator to collect used oil Allow oil to drain completely Return generator to a level surface Crankcase Dipstick hole Use a clean rag to wipe up any spilled oil Replace crankcase dipstick Reinstall ou...

Страница 21: ...should be damp but not dripping Do not run the generator without reinstalling the foam element or excessive piston and cylinder wear may result CAUTION Remove screws then remove the muffler cover as...

Страница 22: ...must be Shipped Run and Stored in the upright position as seen For semi long term storage add fuel stabilizer to prevent stale fuel from causing acid and gum deposits in the fuel system For long term...

Страница 23: ...MAINTENANCE CH O K E O FF Remove the spark plug and pour about 1 teaspoon of 10W30 Engine oil into the spark plug hole Reinstall the spark plug With the 3 in 1 switch in the OFF position pull the rec...

Страница 24: ...er 3 Dirty Air filter 4 Engine needs servicing 1 See pg 17 Don t overload generator 2 Clean or replace fuel filter 3 Replace Air filter 4 Contact service department Engine hunts or falters 1 Choke was...

Страница 25: ...WIRING DIAGRAM 25 Model Revision Level 01 Doc Revision Level 01 Title SCHEMATIC Model PG2300iSCO Doc No 504617 01 Ed Date 11 15 21...

Страница 26: ...O Sensor shuts off the engine notifies the user with a RED indicator light and directs the user to read the Action Label for steps to take The CO Sensor DOES NOT replace carbon monoxide alarms Install...

Отзывы: