Note:
The Economy switch must be turned to the “OFF” position when using electronic
devices that require a large
starting current, such as a compressor.
Parallel Outlets
Located just above the Ground Terminal, the generator’s Parallel Outlets enable a user to run two PG2000
BiSR
generator’s simultaneously. This operation requires specia
l cables. When operating parallel generators, the rated output is
3.0kVA and the rated current is 25A/120VAC. For cables and instructions consult a PULSAR dealer for a PARALLEL
OPERATION CABLE KIT.
Fuel Cap
Turn counterclockwise to remove the fuel cap.
Fuel Cap Air Vent
The fuel cap is equipped with an air vent to stop fuel from flowing to the
carburetor. The Air Vent must be in the “ON” position to allow fuel to flow
so that the engine can run. Turn the Air Vent to the “OFF” position to
stop
fuel flow.
Ground Terminal
The generator’s ground terminal must always be used to connect the
generator to a driven ground rod. Connect the ground terminal to the driven
ground rod with a 12 AWG (American Wire Gage) copper wire. The wire
connects to the terminal between the lock washer and nut. Tighten the nut
securely to ensure good connection. Grounding the generator protects you
from electric shock that results from a build up of static electricity or
undetected ground faults.
1
0
0
WARNING!
Generator must be properly grounded to prevent electrocution.
•
Only operate generator on a level surface.
•
Always connect the nut and ground terminal on the frame to an appropriate ground source.
WARNING!
Never connect generators that are different models.
•
Only connect this generator to another PG2000BiSR Standard Generator.
•
Only use a parallel operation cable kit designed to work with this Generator.
CONTROL PANEL FUNCTIONS
ON
OFF