Pulsar PG15KVTWB Скачать руководство пользователя страница 5

4

 

GENERATOR SAFETY

 

IMPORTANT  SAFETY INFORMATION

 

T

his

 generators are designed for use with electrical equipment that has suitable power requirements. Other uses can 

result in injury to the operator or damage to the generator and other property. 

Most accidents can be prevented if you follow all instructions in this manual and on the generator. The most common 
hazards are discussed below, along with the best way to protect yourself and others. 

Operator Responsibility

 

Know how to stop the generator quickly in case of emergency.

Understand the use of all generator controls, output receptacles, and connections.

Be sure that anyone who operates the generator receives proper instruction. Do not let children operate the generator
without parental supervision.

Carbon Monoxide Hazards

 

Exhaust contains poisonous carbon monoxide, a colorless, odorless gas. Breathing carbon monoxide can cause loss
of consciousness and may lead to death.

If you run the generator in an area that is confined, or even partly enclosed area, the air you breathe could contain
dangerous amount of exhaust gas.

Never run your generator inside a garage, house, or near open windows or doors.

Electric Shock Hazards

 

The generator produces enough electric power to cause a serious shock or electrocution if misused.

Using a generator or electrical appliance in wet conditions, such as rain or snow, or near a pool or sprinkler system,
or when your hands are wet, could result in electrocution. Keep the generator dry.

If the generator is stored outdoors, unprotected from the weather, check all of the electrical components on the
control panel before each use. Moisture or ice  can  cause  a  malfunction  or  short  circuit  in  electrical
components that could result in electrocution.

Do not connect to a building’s electrical system unless an isolation switch has been installed by a qualified electrician.

Do not use the generator without protective switch-off device.

Fire and Burn Hazards

 

The exhaust system gets hot enough to ignite some materials.

Keep the generator at least 1 meter away from buildings and other equipment during operation.

Do not enclose the generator in any structure.

Keep flammable materials away from the generator

The muffler becomes very hot during operation and remains hot for a while after stopping the engine. Be careful
not to touch the muffler while it is hot. Let the engine cool before storing the generator indoors.

Refuel With Care

 

Gasoline is extremely flammable, and gasoline vapor can explode. Allow the engine to cool if the generator has been in 
operation. Refuel only outdoors in a well ventilated area with the engine OFF. Do not overfill the fuel tank. Never smoke 
near gasoline, and keep other flames and sparks away. Always store gasoline in an approved container. Make sure that 
any spilled fuel has been wiped up before starting the engine. 

Содержание PG15KVTWB

Страница 1: ...Model PG15KVTWB www pulsar products com Generator OPERATOR S MANUAL...

Страница 2: ...isfaction and will be pleased to answer your questions and concerns A FEW WORDS ABOUT SAFETY Your safety and the safety of others are very important And using this generator safely is an important res...

Страница 3: ...System 9 Ground Terminal 9 Fuel Gauge 9 VoltMeter 9 Hour Meter 9 BEFORE OPERATION 10 ARE YOU READY TOGET STARTED 10 Knowledge 10 IS YOUR GENERATORREADY TOGO 10 Check the Engine 10 Check the Battery 1...

Страница 4: ...NG 22 SPARKPLUG SERVICE 23 BATTERY SERVICE 24 BatteryRemoval 24 BatteryCharging 25 STORAGE 26 STORAGE RECAUTION 26 Cleaning 26 Fuel 26 STORAGE PROCEDURE 27 STORAGE PRECAUTIONS 28 REMOVALFROMSTORAGE 28...

Страница 5: ...e in wet conditions such as rain or snow or near apool or sprinkler system or when your hands are wet could result in electrocution Keep the generator dry If the generator is stored outdoors unprotect...

Страница 6: ...partially enclosed area the air you breathe could contain a dangerous amount of exhaust gas Never run your generator inside a garage house or near open windows or doors Do not connect to a building s...

Страница 7: ...Use the illustrations on these pages to locate and identify the most frequently used controls CONTROL PANEL LPG PORT THE FIRST STAGE REGULATOR THE SECOND STAGE REGULATOR HOUR METER CIRCUIT BREAKER ENG...

Страница 8: ...7 CONTROLS FEATURES CYLINDER CRANIUM AIR CLEANER OIL TANK CAP EMPTY FULL OIL GAUGE OIL LEVEL DIPSTICK BATTERY OIL DRAIN TUBE STARTER MOTOR...

Страница 9: ...ing and for restarting a warm engine EngineSwitch The engine switch controls the ignition system and it operates the electric starter FUEL VALVE LEVER CHOKE KNOB STOP Stops the engine The engine switc...

Страница 10: ...es that apply to the intended use of the generator Attention It is compulsorily to make protective earthing before operating the generator Protective earthing must correspond to Rules for Installing E...

Страница 11: ...ake care of any problem you find or have your servicing To prevent a possible fire keep the generator at least 1 meter away from building walls and other equipment during operation Do not place flamma...

Страница 12: ...Faulty appliances or power cords can create a potential for electric shock Make sure the electrical rating of the tool or appliance does not exceed that of the generator Never exceed the maximum power...

Страница 13: ...release the key and wait at least 10 seconds before operating the starter again Using the electric starter for more than 5 seconds at a time will Overheat the starter motor and can damage it 5 If the...

Страница 14: ...sconnect the appliance and determine whether the problem is in the appliance or the rated load capacity of the generator has been exceeded Substantial over loading may damage the generator Marginal ov...

Страница 15: ...to 30 minutes Maximum poweris 60Hz 15 kVA GAS 13 5 kVA LPG For continuous operation longer than 30 minutes do not exceed the rated power Rated poweris 60Hz 12 kVA GAS 11 kVA LPG NOTICE High Altitude O...

Страница 16: ...trician and must comply with all applicable laws and electrical codes In some areas generators are required by law to be registered with local utility companies Check local regulations for properregis...

Страница 17: ...emperature operation or use it in dusty conditions consult your servicing dealer for recommendations applicable to your individual needs anduse Remember that your servicing dealer knows your generator...

Страница 18: ...NCESCHEDULE NOTE Replace the paper element only 1 Service more frequently when used industry areas 2 These items should be serviced by your servicing dealer unless you have the proper tools and are me...

Страница 19: ...fuel is not covered underwarranty NOTE Gasoline spoils very quickly depending on factors such as light exposure temperature and time In worst cases gasoline can be contaminated within 30days Using co...

Страница 20: ...fuel from an unfamiliar station try to find out If the fuel contains alcohol if it does confirm the type and percentage of alcoholused If you notice any undesirable operating symptoms while using a g...

Страница 21: ...ible with the environment We suggest you take it in a sealed container to your local service station or recycling center for reclamation Do not throw it in the trash pour it on the ground or pour it d...

Страница 22: ...vice category are on the API label on the oil container AIR CLEANERSERVICE 1 Release four latch tabs from the air cleaner cover and remove the cover 2 Foam airfilter a Remove the foam air filter from...

Страница 23: ...nance Schedule 1 Clean the foam air filter in warm soapy water rinse and allow to dry thoroughly or clean in non flammable solvent and allow todry 2 Dip the foam air filter in clean engine oil then sq...

Страница 24: ...plug wrench commercially available 3 Inspect the spark plugs Replace them if the electrodes are worn or if the insulator is cracked chipped or fouled 4 Measure the spark plug electrode gap with a wir...

Страница 25: ...p or other container for at least fifteen minutes Water under pressure can damage the eye Immediately call aphysician Skin Remove contaminated clothing Flush the skin with large quantities of water Ca...

Страница 26: ...f the battery s ampere hour rating 1 Connect the battery charger following the manufacturer sinstructions 2 Chargethebattery 3 Clean the outside of the battery and the battery compartment with a solut...

Страница 27: ...l tank with fresh gasoline If only partially filled air in the tank will promote fuel deterioration during storage If you keep a container of gasoline for refueling be sure that it contains only fresh...

Страница 28: ...engine and place it in a suitable container c Loosen the carburetor drain screw d Drain the gasoline from the carburetor into the container e Tighten the carburetor drain screw securely 2 Change the...

Страница 29: ...valve lever in the OFF position to reduce the possibility of leakage Place the generator on a level surface Tilting can cause fuel or oil leakage With the engine and exhaust system cool cover the gene...

Страница 30: ...tem can burn you and can ignite some materials Keep the generator level when transporting to reduce the possibility of fuel leakage Move the fuel valve lever to the OFF position When using ropes or ti...

Страница 31: ...Gap or replace spark plug p 23 Spark plug wet with fuel floodedengine Dry and reinstall sparkplug 5 Take generatorto an authorized THIS servicing dealer or refer to shop manual Fuel filter restricted...

Страница 32: ...on afterstarting Switch circuit breaker ON 2 Check the powertool or appliance at a known good AC powersource Faulty power tool orappliance Replace or repair power tool or appliance Stop and restart th...

Страница 33: ...difications to the carburetor If you always operate your generator at altitudes above 1 500 meters have your authorized THIS servicing dealer perform this carburetor modification Even with carburetor...

Страница 34: ...ximatly 1 6L Fuel TankCapacity 40L Spark Plug F7TC NHSPLD Battery 12V 21AH Generator Model Single phase AC output Rated voltage 120V 240V Rated frequency Rated Ampere 100A 50A Rated output 12kW GAS 11...

Страница 35: ...34 TECHNICAL INFORMATION WIRING DIAGRAM...

Страница 36: ...components parts and labor Year 2 Limited coverage on generator engine components parts only Personal use means personal residential household use or recreational use by the retail consumer Commercia...

Страница 37: ...e United States Canada or Mexico Refurbished used demonstration or floor models are not covered by this warranty Products purchased from on line auction websites such as ebay are not covered under thi...

Отзывы: