Pulsar MSC 1512 Скачать руководство пользователя страница 7

www.pulsar.pl 

 

 

 

 

 

MSC1512 

 

 

 

 

 
 

 

 
3. Operating status indication. 

The PSU is equipped with 2 LEDs that indicate operating status of: AC and AUX.  

 

AC- red diode: Under normal status (AC power) the diode is permanently illuminated. The absence of AC 
power is indicated by the AC diode going out.  

 

AUXgreen diode: indicates DC power at the module’s output. Under normal status the diode is 
permanently illuminated. In case of a short circuit or an overload at the output, the diode is off. 

 

4. Operation and use. 
 

4.1. Overload or short circuit  

In case of a short circuit at the 

AUX output, 

the output voltage is automatically cut off

 which is indicated by 

the AUX diode going out. 

The voltage is restored automatically after limitation of current consumption or removing 

the short circuit. 

In  case  of  an  overload  at  the  AUX  output,  the  output  voltage  is  automatically  cut  off

   and/or 

the F1  fuse 

becomes  damaged.  Restoration  of  the  output  voltage  requires  limitation  of  current  consumption  or  removing  the 
short circuit. If the fuse has been damaged, a fuse-element must be replaced. 

 
 

4.2 Maintenance 
 
The  PSU  module  does  not  require  performing  any  specific  maintenance  measures,  however,  in  case  of 

dust,  clean  the  surface  with  compressed  air.  In  case  of  fuse  replacement,  use  a  replacement  of  the  same 
parameters. 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание MSC 1512

Страница 1: ...MSC 1512 v 1 1 MSC 12V 1 5A 24V 1A M PSU module for CCTV EN Edition 2nd 5th Mar 2012 Supersedes the 1st 8th Apr 2009 edition...

Страница 2: ...a supplying component in CCTV systems KD access control SSWiN alarm systems etc It is intended to be wall mounted or fixed inside a device e g camera s enclosure The module delivers current of 12V wit...

Страница 3: ...utput voltage adjustment J Uout voltage AUX 12VDC J Uout voltage AUX 24VDC see module s supply voltage tab 3 Caption jumper on jumper off 2 F1 fuse in the module s power circuit 3 AUX green LED DC pow...

Страница 4: ...AUX F 2A fuse damage requires fuse element replacement F1 fuse F2A 250V Mechanical specifications tab 4 Pcb dimensions 70 x 28 x 70 WxHxD Fixing Mounting holes x 2 fi 3 mm Net gross weight 0 09kg 0 13...

Страница 5: ...e followed accordingly to the application Typical application MSC1512 fig 2 fig 3 Fig 3 Connection of the PSU module and a 12VDC camera in an external enclosure EXAMPLE 27V AC power supply e g PSAC 04...

Страница 6: ...www pulsar pl MSC1512 6 Fig 4 Typical application of the MSC1512 module and the PSAC04244 power supply unit Conditions camera s power a group of cameras P 13W max...

Страница 7: ...cuit at the AUX output the output voltage is automatically cut off which is indicated by the AUX diode going out The voltage is restored automatically after limitation of current consumption or removi...

Страница 8: ...ry out the repairs or if the equipment has been conditionally accepted due to the breaking warranty terms by the claimant 8 All the services rendered by force of the warranty are carried out at the se...

Отзывы: