Page 11
Location
When choosing a location to mount the bracket and
MicroFlow-i
, note the
following:
•
For optimum readings, it is recommended that the
MicroFlow-i
should be
positioned at a 45° angle to the surface of the material being measured.
•
The mounting surface must be vibration-free.
•
The ambient temperature should be between -20ºC and 60ºC.
Mounting
For the best results it is highly recommended to use the
MicroFlow-i
angled
bracket, which is available from your Pulsar distributor, which will ensure that the
MicroFlow-i
can be correctly installed. The bracket can be used if the
MicroFlow-
i
sensor is to be mounted on its own in a specific location or along with a Pulsar
dBi or dB level transducer. Please see ‘
Angled Mounting Bracket
’ for
dimensions of this bracket, please note that the drawing is not to scale.
‘
Mounting sensor to a bracket
’ illustrates how you would install the sensor to
one of Pulsar’s angled brackets.
The
MicroFlow-i
angled bracket should be mounted by marking and drilling the
holes suitable for fixing your screws/bolts (length to suit your application) and
then fixing the bracket in place.
Important Information
When installing the
MicroFlow-i
it is recommended that it is mounted at
least 1m away from moving persons or machinery.
All electronic products are susceptible to electrostatic shock,
so follow proper grounding procedures during installation.
Содержание MicroFlow-i
Страница 1: ...MICROFLOW INSTRUCTION MANUAL...
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 12: ...Page 6 EU Declaration of Conformity...
Страница 27: ...Page 21 Diagram 4 Diagram 3 Distance Distance Distance Distance Distance...
Страница 32: ...Page 26 This page is left blank intentionally...
Страница 34: ...Page 28 This page is left blank intentionally...