INSTALLATION
LUXEOS
R
ANGE
INGR
OUND
7650 - L9 IG - INST
LUMINAIRE & LUMINAIRE DRIVER - GROUND MOUNT INSTALLATION
L
UX
EOS
9 Inground
VIVID COLOUR & TUNABLE WHITE
LED INGROUND FLOOD FOR ARCHITECTURAL LIGHTING
• Do not operate in locations where the ambient temperature will exceed 50°C
.
• Ensure that air can freely flow over the luminaire heat sink.
• Use only with attachments and accessories specified by Pulsar.
• Use only with the Pulsar ground mount as specified in this instruction leaflet.
Important
• Installation must be carried out in accordance with local and/or national
Installation codes and regulations.
• Ensure that the ground mount is separately electrically earthed to ground.
• The LuxEOS 9 Inground luminaire should only be used with the supplied driver,
connecting the luminaire to another driver will
void the warranty
.
1. Install the driver into the ground mount
The ground mount has an internal bracket to fix and secure the LuxEOS 9 inground driver,.
Slot the driver into the bracket ensuring that it is firmly held in place.
2. Install and connect the power and DMX to the driver.
Hardwire the Qui combined power and control input cable ensuring that connections are made in a suitable sealed and potted IP68 enclosure.
Once installed, connect the driver via the Qui Power & DMX connectors ensuring that the connectors
click
and lock into place.
3. Connect the luminaire
Connect the luminaire to the driver via the X-Lok connector, to connect, line up the arrows and push until the connector
clicks
into place.
4. Install the luminaire into the ground mount
Secure the luminaire to the ground mount with four M4 fixing screws through the holes on the front bezel.
5. Test the luminaire
Ensure that all connections are secure correctly connected and sealed, then power up and test the luminaire.
Click !
4. Install the luminaire
2. Connect the Power and DMX
1. Install driver
3. Connect the luminaire
Click !
Installation of the luminaire & driver into a pre-installed ground mount
Luminaire - Ground mount
P U L S A R
Part of DW Windsor Ltd, Pindar Road, Hoddesdon, Hertfordshire, EN11 0DX, UK
www.dwwindsor.com/pulsar | [email protected] | +44 (0)1992 4
74