Pulsar LuxEOS 9 Скачать руководство пользователя страница 1

1 of 10

  

INSTALLATION

    LUXEOS

 R

ANGE

  INGR

OUND

7650 - L9 IG - INST

Important

• LuxEOS luminaires must be installed by a qualified electrician.
• Installation must be carried out in accordance with local and/or national

electrical installation codes of practice.

• Isolate the mains supply during installation and whenever subsequently 

disconnecting or reconnecting the luminaire or luminaire driver.

Power  &  DMX  Data  In      

Typical Connections

  L

UX

EOS

 9 Inground 

VIVID COLOUR & TUNABLE WHITE

LED INGROUND FLOOD FOR ARCHITECTURAL LIGHTING

WIRING DETAILS

IP68 Connection box (potted)

Provided by others

X-Lok IP68 

Connector 

LuxEOS IG 9 driver with 

Qui input

& X-Lok output connectors

Qui IP68 

connector (M)

1m Cable 

Qui (F) to open ends

Qui IP68 

connector (F)

1m Cable - Qui (F) to open ends 

(

LUXIHWX.XL01.XX.NONE.XXX.XX.XX)

Green - Earth
White - Neutral
Black  - Live
Data - Screen

White - Data + In

Green - Data  - In

Blue - Data + Out

  

Red -  Data  - Out

  

Power & DMX Data Link     

Power & DMX Data Link     

1m Cable 

Qui (F) to open ends

1m Cable 

Qui (F) to open ends

 

120Ω termination resistor must be

 fitted if the luminaire is last in the DMX data line

Connection details

LuxEOS IG 9 luminaire

The Qui (F) to open end combined power and DMX cable (LUXIHWX.XL01.XX.NONE.XXX.XX.XX) is necessary as part of the first fix solution to enable connections to existing 

wiring. The bare end of the cable should be connected as shown above using an IP68 installation connection box, care should be taken to separate the mains and control cabling, 

the female Qui connector can then be plugged into the LuxEOS 9 inground driver to provide power and DMX-RDM control data.
If the driver / cables are installed at an earlier point to the luminaire or if the luminaire is removed, then the power must be disconnected and the supplied blanking cap be fitted 

to the Qui connector to prevent any ingress to the terminals.

Provided by others

Provided by others

IP68 Connection box (potted)

IP68 Connection box (potted)

• Ensure the correct polarity when wiring, if in any doubt please contact Pulsar.

Any damage caused to the luminaire or luminaire driver by electrical 

misconnection will 

void the warranty.

• Unless authorised by Pulsar, field repairs or opening of the luminaire or 

luminaire driver will 

void the warranty.

P U L S A R  

Part of DW Windsor Ltd, Pindar Road, Hoddesdon, Hertfordshire, EN11 0DX, UK 

www.dwwindsor.com/pulsar  |  [email protected]  |  +44 (0)1992 4

74

600

Содержание LuxEOS 9

Страница 1: ...data line Connection details LuxEOS IG 9 luminaire The QuickLink F to open end combined power and DMX cable LUXIHWX XL01 XX NONE XXX XX XX is necessary as part of the first fix solution to enable con...

Страница 2: ...RDM over DMX The following RDM Parameter I D S PIDS are supported Discovery 0001 Discovery_Branch_Unique 0002 Discovery_Mute 0003 Discovery_Un_mute Status 0020 Queued_Messages 0030 Status_Messages 003...

Страница 3: ...t LuxEOS 9 Inground 3 9 kgs Dimensions with connector 295mm Dia x 132mm D All dimensions in mm LUXEOS 9 Inground VIVID COLOUR TUNABLE WHITE LED INGROUND FLOOD FOR ARCHITECTURAL LIGHTING Side view P U...

Страница 4: ...mm Side view Top view Enclosure Driver enclosure with cables Luminaire driver Weight Driver with cables 1 1 kgs Dimensions enclosure 140mm W x 160mm H x 80mm D X Lok IP68 connector QuickLink connector...

Страница 5: ...UND FLOOD FOR ARCHITECTURAL LIGHTING Front Rear view Left Right view Ground Mount Top view Perspective view Integrated driver enclosure bracket Cable entry front rear Luminaire fixing points 4 x M4 We...

Страница 6: ...N 2 DRAINAGE STABILITY The hole for the ground mount should be 600mm deep to allow for at least 200mm of hard surface or drainage material underneath the ground mount The hole should be 500mm wide at...

Страница 7: ...nto the bracket ensuring that it is firmly held in place 2 Install and connect the power and DMX to the driver Hardwire the QuickLink combined power and control input cable ensuring that connections a...

Страница 8: ...o open ends LUXIHWX XL01 XX NONE XXX XX XX Mains input DMX in thru connections Luminaire driver enclosure Luminaire control cable LuxEOS 9 Inground luminaire Ground mount QuickLink connector Important...

Страница 9: ...ering magnet on the glass to pick up the internal magnet Once attached drag the steering magnet around the perimeter of the glass to set the tilt rotation to the desired angle Steering magnet Tilt 8 8...

Страница 10: ...hould pressure washers be used for cleaning The light source contained in this luminaire shall only be replaced by Pulsar or an authorised service agent or a similar qualified person As part of our co...

Отзывы: