Table 4. PSU parameters. 

Model 

HPSDC-12V4x1A 

Power supply 

~ 100 

– 240 V; 1A; 50/60 Hz 

Inrush current 

40 A 

PSU power 

48 W max. 

Output current 

4x 1 A   

Efficiency 

82% 

Output voltage (factory settings) 

12 V DC 

Adjustment range U

AUX

 

independent for each output: 12 

– 15 V DC

 

Ripple voltage 

50mV p-p max. 

Short circuit protection SCP 

4x F 1A glass fuse fast blow 

Overload protection OLP 

105 

– 150% PSU power, automatically recovered 

Surge protection 

varistors 

Over voltage protection OVP 

>19V (triggering automatic return) 

Protection in 230 V circuit 

glass fuse T5A 

LED operation indication 

- LEDs on PCB of power supply unit: The green L1...Ln LEDs indicate the power 

supply status on the outputs: AUX1...AUX4 

Enclosure dimensions                    
(WxH) [±2mm] 

270x200 

Enclosure dimensions                    
(W

1

xH

1

xD

1

+D) [±2mm] 

2758 

Fixing (WxH) 

237x170 

Net/gross weight 

1,8/1,9 [kg] 

Connectors 

Power supply: 0,5 

– 1,5 mm

2

 (AWG 26 

– 16) 

Notes 

Convectional cooling 

 
Table 5. Operation safety.

 

 

Table 6. Operating parameters. 

      

 

 

2. Installation. 

 
2.1. Requirements. 

PSU is to be mounted by a qualified installer, holding relevant permits and licenses (applicable and required for a 

given country) for 230 V in and low-voltage installations. Unit should be mounted in confined spaces, in accordance, with 
normal relative humidity (RH=90% maximum, without condensing) and temperature from  -

10°C to +40°C. The PSU shall 

work in a vertical position that guarantees sufficient convectional air-flow through ventilating holes of the enclosure.  

As  power  supply  is  designed  for  a  continuous  operation  and  is  not  equipped  with  a  power-switch, therefore, an 

appropriate  overload  protection  in  power  supply  circuit  should  be  provided.  Moreover,  the  user  shall  be  informed  about 
the method of unplugging (most frequently through separating and assigning an appropriate fuse in the fuse-box).  
The electrical system shall follow valid standards and regulations.  

 

 

2.2. Installation procedure.

  

 

Before  installation,  cut  off  voltage  in  230  V  power-supply  circuit.  To  switch  power  off,  use  an 
external  switch,  in  which  distance  between  contacts  of  all  poles  in  disconnection  state  is  not  less 
than 3mm. 
 

 

         It is required to install an installation switch with a nominal current of 6 A in power supply circuits outside 
power supply unit. 

Protection class EN 62368-1 

I (first) 

Electrical strength of insulation: 

- between input and output circuits of the PSU 
- between input circuits of the PSU 
- between input circuit and protection circuit   
- between output circuit and protection circuit   

 
2500 V AC min. 
2500 V AC min. 
1500 V AC min. 
  500 V AC min. 

Insulation resistance: 
- between input circuit and output or protection circuit 

 
100 MΩ, 500 V DC  

Operating temperature 

-

10ºC...+40ºC  

Storage temperature 

-

20ºC...+60ºC 

Relative humidity 

20%...90%, 

 without condensation 

Vibrations during operation 

unacceptable 

Impulse waves during operation 

unacceptable 

Direct insolation 

unacceptable 

Vibrations and impulse waves during transport 

According to PN-83/T-42106 