Pulsar HPSB 2524B Скачать руководство пользователя страница 2

www.pulsar.pl                                                          HPSB2524B                                                      

GREEN POWER

 

 

 

2

 

Features: 

 

 

DC 27,6V/2,2A uninterruptible power supply

*

  

 

fitting battery: 2x7Ah/12V  

 

wide range of mains supply: 176

÷264V  

 

high efficiency 80% 

 

battery charging and maintenance control 

 

excessive discharging (UVP) protection 

 

battery charge current 0,3A 

 

battery output full protection against short-
circuit and reverse polarity connection 

 

 

LED indication  

 

protections: 

 

SCP short-circuit protection 

 

OVP overvoltage protection 

 

overvoltage protection (input AC) 

 

against sabotage 

 

overload protection (OLP) 

 

warranty 

– 2 year from the production date   

 

CONTENTS: 
1. Technical description. 

1.1 General description 
1.2 Block diagram 
1.3 Description of PSU components and connectors. 
1.4 Specifications 

2. Installation. 

2.1 Requirements 
2.2 Installation procedure 

3. Operating status indication. 

3.1 LED indication of operating status 

4. Operation and use. 

4.1 Overload or short circuit of the PSU output (SCP on) 
4.2 Disconnection of discharged battery 
4.3 Maintenance 

 

 
1. Technical description. 
 

1.1 General description. 

A buffer PSU is intended for uninterrupted supply to devices that require stabilised voltage of 

24V DC (+/-

15%).

 The PSU provides voltage of 

U=27,6V DC 

with output current of 

I=2,2A + 0,3A for battery charge

*

.

  In case 

of power decay, a battery back-up is activated immediately.  The PSU is constructed based on the switch mode 
PSU, with high energy efficiency. The PSU is housed in a metal enclosure (colour RAL 9003) which can 
accommodate two 7Ah/12V batteries. A micro switch indicates door opening (front cover). 

 

During normal operation, the total current drawn by the equipment may not exceed I = 2,2A

*

.   

Maximum battery charge current: 0,3A

*

.  

Total device c battery: 2,5A max

*

 

OPTIONAL POWER SUPPLY CONFIGURATIONS:  

(

visualisation available at:

 www.pulsar.pl) 

 

1. Buffer power supply unit  HPSB 27,6V/2x1A/2x7Ah. 

- HPS  LB2 2x1A (AWZ586) + 2x7Ah 

2. Buffer power supply unit  HPSB 27,6V/4x0,5A/2x7Ah.

 

- HPS  LB4 4x0,5A (AWZ574 or AWZ576) + 2x7Ah 

3. Buffer power supply unit  HPSB 27,6V/24V/2,2A/2x7Ah.

 

- HPS RN25024 (27,6V/24V) + 2x7Ah 

4. Buffer power supply unit  HPSB 27,6V/24V/2x1A/2x7Ah.

 

- HPS RN25024 (27,6V/24V) + LB2 2x1A (AWZ586) + 2x7Ah 

5.

 

Buffer power supply unit  HPSB 27,6V/24V/4x0,5A/2x7Ah.

 

       - HPS RN25024 (27,6V/24V) + LB4 4x0,5A (AWZ574 or AWZ576) + 2x7Ah 

6.

 

Buffer power supply unit  HPSB 

27,6V/5V÷18V/5V÷18V/2A÷1,3A/2x7Ah.

 

       - HPS 

DCDC20 (5V÷18V/2A÷1,3A) + 2x7Ah 

                                                 

*

 

Refer to chart 1

 

Содержание HPSB 2524B

Страница 1: ...HPSB 2524B v 1 0 HPSB 27 6V 2 2A 2x7Ah Buffer switch mode power supply unit EN Edition 2 from 24 10 2016 Supersedes the edition 1 from 30 09 2014 ...

Страница 2: ...at require stabilised voltage of 24V DC 15 The PSU provides voltage of U 27 6V DC with output current of I 2 2A 0 3A for battery charge In case of power decay a battery back up is activated immediately The PSU is constructed based on the switch mode PSU with high energy efficiency The PSU is housed in a metal enclosure colour RAL 9003 which can accommodate two 7Ah 12V batteries A micro switch indi...

Страница 3: ...e tab 2 3 green LED indicates AC power 4 potentiometer output voltage adjustment 5 BAT GND battery outputs BAT red GND black 6 TAMPER contact sabotage protection NC 7 Additional connector for LED indication Tab 1 The elements of the PSU Element Fig 2 Description L N L N power supply connector PE PE Protection connector electric shock protection V V DC supply output DC supply output GND Tab 2 Outpu...

Страница 4: ...y charge refer to chart 1 Output current tAMB 40 C 1 45A 0 3A battery charge refer to chart 1 Voltage adjustment range 24 28V DC Ripple 120mV p p max Current consumption by PSU systems 75 mA Battery charge current 0 3A max 2x 7Ah 5 Short circuit protection SCP electronic Overload protection OLP U 105 150 of power supply automatic return Battery circuit protection SCP and reverse polarity connectio...

Страница 5: ...ables can be led Convectional cooling Operation safety tab 5 Protection class EN 60950 1 2007 I first Protection grade EN 60529 2002 U IP20 Electrical strength of insulation between input and output circuits of the PSU I P O P between input circuit and PE protection circuit I P FG between output circuit and PE protection circuit O P FG 3000 V AC min 1500 V AC min 500 V AC min Insulation resistance...

Страница 6: ...andards and regulations 2 2 Installation procedure 1 Before installation cut off the voltage in the 230V power supply circuit 2 Mount the PSU in a selected location and connect the wires 3 Connect the power cables 230Vac to L N clips of the PSU Connect the ground wire to the clip marked by the earth symbol PE PSU module connector Use a three core cable with a yellow and green PE protection wire to...

Страница 7: ...he restoration of the voltage takes place immediately after the failure overload is over 4 2 Disconnection of discharged battery The PSU is equipped with the discharged battery disconnection system During the battery assisted operation reducing voltage below 19V at the battery terminals will cause battery disconnection 4 3 Maintenance Any and all maintenance operations may be performed following t...

Страница 8: ...c equipment should be disposed of separately from normal household waste CAUTION The power supply unit is adapted for cooperation with the sealed lead acid batteries SLA After the operation period they must not be thrown but recycled according to the applicable law Pulsar Siedlec 150 32 744 Łapczyca Poland Tel 48 14 610 19 40 Fax 48 14 610 19 50 E mail biuro pulsar pl sales pulsar pl http www puls...