background image

www.pulsar.pl 

                                HPSB11A12C 

 

 

5

 

1.4 Specifications:  
- electrical parameters (tab.3) 
- mechanical parameters (tab.4) 
- operation safety (tab.5) 
- operating parameters (tab.6) 

      

Electrical parameters (tab. 3) 

PSU type 

A (EPS - External Power Source) 

Mains supply 

176÷264V AC 

Current up to 

1.4A@230VAC 

Power frequency 

50÷60Hz  

Supply power 

155W max.  

Efficiency 

83% 

Output voltage 

13,8V DC – buffer operation 
9,5V÷13,8V DC – battery operation 

Output current 

10 A + 1A battery charge 
7 A + 4A battery charge 

Output current t

AMB

<30°C 

10 A + 1 A battery charge - refer to chart 1 
  7 A + 4 A battery charge - refer to chart 1 

Output current t

AMB

=40°C 

6,7 A + 1 A battery charge - refer to chart 1 
3,7 A + 4 A battery charge - refer to chart 1 

Voltage adjustment range 

12÷14VDC 

Ripple 

120mV p-p max. 

Battery charge current 

1 A / 4 A @ 17Ah (± 5%) jumper selectable 

Short-circuit protection SCP 

electronic 

Overload protection OLP 

PTC polymer fuse 

Overvoltage protection OVP 

U>115% ÷ 150% of the output voltage (set), power 
cut off, automatic return 

Excessive discharge protection UVP 

U<9,5 V (± 5%) – 

disconnect of connection battery  

LED indication:  
- AC diode indicating AC power status 
- AUX diode indicating DC power status at 
the PSU output 

 
- red, normal status – on, failure: off 
- green, normal status – on, failure: off 

Protection against sabotage: 
- TAMPER indicates enclosure opening 

 
- microswitch, NC contacts (enclosure closed), 
0,5A@50V DC (max.) 

 
Mechanical parameters (tab. 4) 

Enclosure dimensions 

280 x 292 x 80 + 8  [mm] (WxHxD) 

Fixation 

See figure 2 

Fitting battery 

17Ah/12V (SLA) max. 

Net/gross weight 

2,4 / 2,6 kg 

Enclosure  

Steel plate DC01, thickness: 0,7mm, colour: RAL 9003 

Closing 

Cheese head screw x 2 (at the front), (lock assembly possible) 

Connectors 

Power-supply: Φ0,63-2,50 (AWG 22-10) 
Outputs: Φ0,63-2,50 (AWG 22-10), battery output BAT: 6,3F-2,5  
TAMPER output: wires  

Notes 

The enclosure does not touch the assembly surface so that cables can be led. 
Convectional cooling. 

     

Operation safety (tab.5) 

Protection class PN-EN 60950-1:2007 

I (first) 

Protection grade PN-EN 60529: 2002 (U) 

IP20 

Electrical strength of insulation: 
- between input input and output circuits of the PSU (I/P-O/P) 
- between input circuit and PE protection circuit (I/P-FG) 
- between output circuit and PE protection circuit (O/P-FG) 

 
3000 V/AC min. 
1500 V/AC min. 
500  V/AC min. 

Insulation resistance: 
- between input circuit and output or protection circuit 

 
100 MΩ, 500V/DC  

Содержание HPSB 11A12C

Страница 1: ...HPSB 11A12C v 1 0 HPSB 13 8V 10A 17Ah Buffer switch mode power supply unit EN Edition 4 from 12 11 2013 Supercedes the edition 3 from 16 09 2013 ...

Страница 2: ...ce 1 Technical description 1 1 General description A buffer PSU is used for an uninterrupted supply to devices requiring stabilised voltage of 12V DC 15 The PSU provides voltage of 13 8 V DC Current efficiency 1 Output current 10 A 1 A battery charge 2 Output current 7A 4 A battery charge Total device current battery 11A max In case of power decay a battery back up is activated immediately The PSU...

Страница 3: ...lock diagram of the PSU 1 3 Description of PSU components and connectors tab 1 tab 2 fig 2 Part no Fig 2 Description 1 PSU module 2 connectors see tab 2 3 green LED indicates AC power 4 potentiometer output voltage adjustment 5 BAT GND battery outputs BAT red GND black 6 TAMPER contact of sabotage protection NC 7 Additional connector for LED indication 8 Selection jumper for charging current Ibat ...

Страница 4: ...www pulsar pl HPSB11A12C 4 Fig 2 The view of the PSU ...

Страница 5: ...D indication AC diode indicating AC power status AUX diode indicating DC power status at the PSU output red normal status on failure off green normal status on failure off Protection against sabotage TAMPER indicates enclosure opening microswitch NC contacts enclosure closed 0 5A 50V DC max Mechanical parameters tab 4 Enclosure dimensions 280 x 292 x 80 8 mm WxHxD Fixation See figure 2 Fitting bat...

Страница 6: ...t guarantees sufficient convectional air flow through ventilating holes of the enclosure Before installation prepare a PSU load balance 1 Output current 10 A 1 A battery charge 2 Output current 7A 4 A battery charge Total device current battery 11A max As the PSU is designed for a continuous operation and is not equipped with a power switch therefore an appropriate overload protection shall be gua...

Страница 7: ...ery output 0V BAT cable GND black 7 Check the PSU operation indicator green LED 8 Check the PSU output voltage the PSU voltage without load should amount to U 13 8V DC 9 After installing and checking proper working the enclosure can be closed 3 Operating status indication 3 1 LED indication of operating status The PSU is equipped with two diodes on the front panel 4 Operation and use 4 1 Overload ...

Страница 8: ...r that within 14 days from the delivery to the service centre of the manufacturer 6 The repair period mentioned in item 5 may be prolonged if there are no technical possibilities to carry out the repairs or if the equipment has been conditionally accepted due to the breaking warranty terms by the claimant 7 All the services rendered by force of the warranty are carried out at the service centre of...