background image

www.pulsar.pl                                                           AWZ222                                                   

GREY POWER plus

  

 

 

12 

 

 
 
 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

WEEE MARK 

 

According to the EU WEE Directive 

– It is required not to dispose of electric or 

electronic waste as unsorted municipal waste and to collect such WEEE separately. 

      The power supply unit is adapted for a sealed lead-acid battery (SLA). After the operation period it must not be disposed of but 

recycled according to the applicable law. 

Pulsar  

Siedlec 150,  32-744 Łapczyca, Poland 

Tel. (+48) 14-610-19-40, Fax. (+48) 14-610-19-50 

e-mail: 

[email protected]

[email protected]

 

http:// 

www.pulsar.pl

www.zasilacze.pl

 

 

 

 

Содержание GREY POWER plus AWZ 222

Страница 1: ...AWZ 222 v 2 3 AWZ 13 8V 2A 17Ah LM Linear buffer power supply unit Grade 2 EN Edition 9 from 02 11 2017 Supercedes the edition 8 from 23 01 2017 GREY POWER plus...

Страница 2: ...er failure protections SCP short circuit protection OLP overload protection over voltage protection OHP overheat protection surge protection against sabotage warranty 5 years from the production date...

Страница 3: ...battery space for a 17Ah 12V battery It is fitted with micro switches indicating unwanted door opening front panel The power supply is pre configured for use in alarm systems stage 1 and 2 in accorda...

Страница 4: ...VP optical indication for activating the over voltage system FBAT fuse in the battery circuit F3 15A 250V Terminals TAMPER antisabotage protection microswitch connector APS technical output indicating...

Страница 5: ...500mA 250V Battery connectors BAT red BAT black Fig 3 The view of the PSU 1 4 Specifications electrical specifications tab 3 mechanical specifications tab 4 operation safety tab 5 operating specificat...

Страница 6: ...ery protection UVP U 10V 0 5V disconnection of battery terminal Tamper protection TAMPER indicates unwanted opening of the enclosure microswitch NC contacts enclosure closed 0 5A 50V DC max Technical...

Страница 7: ...ng an appropriate fuse in the fuse box The electrical system shall follow valid standards and regulations 2 2 Installation procedure Caution Before installation make sure that the voltage in the 230V...

Страница 8: ...e EPS FLT technical output after some time determined by TAC pins battery disconnection LED indication acoustic indication and the APS FLT technical output after a battery test have been completed 10m...

Страница 9: ...e lag T 0s J1 J2 time lag T 5min J1 J2 time lag T 1h J1 J2 time lag T 6h PSU FLT output indicating PSU failure The output indicates PSU failure Under normal status correct operation the output is shor...

Страница 10: ...board and hold for 3s Disconnecting the PSU from the battery press the STOP button on the main board and hold for 3s 4 2 Deep discharge battery protection UVP The PSU is equipped with the disconnectio...

Страница 11: ...e below shows how long does it take to charge a fully discharged battery up to min 80 of its nominal capacity Table 9 Battery charging time 17Ah battery charging time up to the capacity of 0 8 C Charg...

Страница 12: ...l waste and to collect such WEEE separately The power supply unit is adapted for a sealed lead acid battery SLA After the operation period it must not be disposed of but recycled according to the appl...

Отзывы: