Pulsar GREEN POWER CCTV PoE POE044812B Скачать руководство пользователя страница 5

www.pulsar.pl                                                      POE044812B   

GREEN POWER CCTV PoE

 

 

 

Component No. 

[Fig. 3] 

Description 

[1] 

The module of the switch mode PSU 

[2] 

LED light indicating correct operation of the switch mode PSU 

[3] 

V1 ADJ potentiometer 

– regulation of the power supply output voltage 

[4] 

PoE module 

[5] 

Connectors for connecting the batteries: +BAT = red, - BAT = black 

[6] 

TAMPER 

– microswitch (contacts) of antisabotage protection

 (NC)

 

[7] 

Plate for mounting the network switch (Ethernet switch / hub) 

Tab. 2. Components of the PSU (see Fig. 3). 

 

1.4 Technical parameters. 

    - electrical parameters (Table 3) 
    - mechanical parameters (Table 4) 
    - safety of use (Table 5) 
    - operation parameters (Table 6) 
 

      Electrical parameters (Table 3). 

Mains supply 

176

÷264V AC  

Current consumption 

0,8A@230V AC typ. 

PSU’s power 

70W max. 

Efficiency 

88% 

Output voltage 

44V 

÷ 54V DC – buffer operation 

38V 

÷ 54V DC – battery operation 

The adjustment range of the output voltage 

48÷55V DC 

Output current t

AMB

<30°C 

4 x 0,25A 

– see diagram 1 

Output current t

AMB

=40°C 

4 x 0,2A 

– see diagram 1 

Ripple voltage  

150 mV p-p max. 

Current consumption by the PSU  

65mA 

Battery charging current 

0,3A max. / 

4x7Ah (± 5%) 

Approximate backup time 

9h 43min 

Short-circuit protection SCP 

PoE MODULE 
4 x F 0,5A or 4 x PTC 0,5A (jumper selectable) 
PSU MODULE 
105% ÷ 150% of PSU power, electronic current limiting 

Overload protection OLP 

105% ÷ 150% of PSU power, electronic current limiting 

Battery circuit protection SCP and reverse  
polarity connection 

melting fuse 

Overvoltage protection OVP 

>62V (automatic return) 

Deep discharge battery protection UVP 

U<38V (± 5%) – disconnecting the battery terminal 

Surge protection 

4 x varistor 

Antisabotage protection: 
- TAMPER output indicating enclosure opening 

 
- microswitch, NC contacts (enclosure closed), 
0,5A@50V DC (max.) 

Optical indication of operation: 

YES 

– LED lights  

Technical outputs: 
- FPS technical output indicating output fuse 
activation 
 
 

 
- OC type, 50mA max.  
Normal operation:  L state (0V),  
failure: H state (hi-Z), (automatic return once the normal 
operation is restored) 
- relay type: 1A@ 30VDC/50VAC, delay time: approximately 
10 seconds 

F1 ÷ F4 fuses 

F 0,5A or PTC 0,5A 

       
       
 
 
 
 
 
 
 
 

Содержание GREEN POWER CCTV PoE POE044812B

Страница 1: ...POE044812B v 1 0 PoE 54V 4x0 3A 4x7Ah PoE buffer power supply for up to 4 IP cameras EN Edition 3 from 15 11 2017 Supersedes the edition 2 from 22 11 2016 GREEN POWER CCTV PoE...

Страница 2: ...ay and OC type LED optical indication protections SCP short circuit protection OVP overvoltage protection Surge protection Antisabotage protection OLP overload protection Mounting plate for mounting t...

Страница 3: ...AUX1 etc In addition the FPS output hi Z state and LFPS LED are activated and the relay contacts change their position The PSU is housed in a metal enclosure with signaling panel equipped with a micr...

Страница 4: ...camera connection 7 Network inputs Ethernet 8 FPS technical output indicating failure OC type 9 FPS technical output indicating failure relay type 11 Optional external optical indication connector fac...

Страница 5: ...agram 1 Output current tAMB 40 C 4 x 0 2A see diagram 1 Ripple voltage 150 mV p p max Current consumption by the PSU 65mA Battery charging current 0 3A max 4x7Ah 5 Approximate backup time 9h 43min Sho...

Страница 6: ...se Table 5 Protection class PN EN 60950 1 2007 I first Protection grade PN EN 60529 2002 U IP20 Insulation electrical strength between input network circuit and the output circuits of the PSU I P O P...

Страница 7: ...the camera can be done using UTP 3 cable networks with data rates up to 10 Mbit s or UTP 5 cable Due to the lower resistance wiring it is recommended especially at large distances between the power s...

Страница 8: ...l RED LED on The PSU supplied with 230V AC voltage off no 230V AC mains supply RED LED on DC voltage at the output of the switch mode PSU off no DC voltage at the output of the switch mode PSU RED LED...

Страница 9: ...or PTC polymer fuses The Fx PTCx jumper position determines which fuse is used If the power supply load current exceeds Imax 110 150 25 C of the PSU power the output voltage is automatically disconne...

Страница 10: ...tronic equipment should be disposed of separately from normal household waste CAUTION The power supply unit is adapted for cooperation with the sealed lead acid batteries SLA After the operation perio...