background image

    LUXEOS

 R

ANGE

  

P U L S A R  

    

1 Pembroke Avenue, Waterbeach, Cambridge, CB25 9QP

www.pulsarlight.com    [email protected]    +44 (0) 1223 403 500

8 of 8

  

INSTALLATION

7650-FIRA-INST-ALL

    FIR
A

 R

ANGE

  FL
OODS

ADDITIONAL INFORMATION

Standards

Fira Pro & Fira Ultra luminaires comply with the following international and national harmonised standards
Electrical Safety - EN 60598, EN 60598-2-13, EN 61347
EMC - EN 55015, EN 61547
RoHS - EN 50581
Photobiological – EN 62471
WEEE - EN 50419
Protection – IP66 / IK9

Power Requirements

Fira Pro & Fira Ultra   120 -277V AC @ 50/60Hz   30W

Product Weights

Fira Pro 

  4.4 kgs 

Fira Ultra 

  4.5 kgs

Portable Appliance Testing

Fira Pro & Fira Ultra luminaires may be safely Earth Bond and Insulation tested (500V).

As part of our commitment to continuous improvement PULSAR  may change the specifications of its products without prior notification or public announcement.
All descriptions, illustrations, drawings and specifications in this publication present only general particulars and shall not form part of any contract. 
Please visit our website www.pulsarlight.com for the most up to date information.

Warranty

Five years from the date of original purchase. 
The warranty covers defects in manufacturing workmanship and materials. It is limited to parts and labour. 
The warranty becomes void if the product is :-
  A   Misused.
  B   Not used in accordance with the instructions. 
  C   The cable connections are not made according to our instructions if the unit is used in damp or wet environments.
  D  Repairs are made by unauthorised persons.
  E   The serial number label has been removed or defaced. 

Pulsar’s maximum liability shall not exceed the price paid for the product. 
In the unlikely event of a fault occurring, do not use without repair, return the product, with a description of the fault, to your supplier or direct to Pulsar for immediate attention.
Full warranty details are available on request or from our website at www.pulsarlight.com.

Qu Cable Colours  (Power)

Green 

 

Earth - Ground

Black 

 

Live Phase

White  

Neutral

Qu Cable Colours  (Data in)

White 

 

DMX +

Green 

 

DMX  -

Shield  

Screen

Qu Cable Colours  (Data through)

Red 

 

DMX +

Blue 

 

DMX  -

Shield  

Screen

DMX Cable Colours  (Pulsar)

White 

 

DMX +

Blue 

 

DMX  -

Shield  

Screen

Mains Supply Cable Colours (Harmonised)

Green/Yellow 

Earth - Ground

Brown 

 

Live Phase

Blue  

Neutral 

  Fira Pro & Fira Ultra

COMPACT LED FLOODS FOR ARCHITECTURAL LIGHTING

Maintenance

Fira Pro & Fira Ultra luminaires should be regularly tested and inspected, and as part of this checked for the build up of external moss and debris which can reduce the 
light output. If cleaning is required, then a mild water based detergent should be used, care should be taken to avoid the use of harsh solvent based cleaning materials as
this could result in damage to the luminaire. Under no circumstances should pressure washers be used for cleaning.

Содержание Fira Pro

Страница 1: ...ther purpose Unless authorised by Pulsar field repairs of the luminaire will void the warranty MAINS DATA CONNECTIONS DMX In Power In QuickLINK Cable Link Link Link Link Power Data In Link Link Link Link QuickLINK Cable QuickLINK Cable QuickLINK Cable QuickLINK Cable Typical Connections Fira Ultra shown LuxCONNECT IP66 Hardwired connection boxes with separate Power DMX wiring QuickLINK luminaire c...

Страница 2: ...ble end should be stripped to between 9 and 11mm before inserting into the connectors Ensure connections are made in accordance to the markings on the PCB failure to do so may result in damage to the luminaire DMX Before fitting the DMX cable each cable end should be stripped to between 8 5 and 9 5mm before inserting into the connector Ensure connections are made in accordance to the markings on t...

Страница 3: ...uture software releases or hardware add ons Single Colour SC 100 50 0 Channel 1 Custom 256 128 0 Bit RDM Start addresses are configured externally via RDM over DMX The following RDM Parameter I D S PIDS are supported Discovery 0001 Discovery_Branch_Unique 0002 Discovery_Mute 0003 Discovery_Un_mute Status 0020 Queued_Messages 0030 Status_Messages 0031 Status_ID_Description RDM Information 0050 Supp...

Страница 4: ...mounting brackets and remove the brackets Carefully remove the front glass taking care to not damage the rubber seal Locate and remove the existing HBS film Remove the replacement HBS from its packing sleeve The beam angle description is printed on the lower and right sides Install the new HBS sheet centrally orientated with the Beam Angle legend readable from the front of the luminaire Note if th...

Страница 5: ...TS LOUVRES Attachments for Glare 3 Attachments are available to reduce light glare from Fira luminaires these being a 50mm Full Snoot Half Snoot and Louvre Each attachment is fitted with the supplied M4 fixing screws as shown below Fira Ultra with Full Snoot Fira Ultra with Louvre Fira Pro with Half Snoot Fixing Screws Fixing Screws Fixing Screws Fira Pro Fira Ultra COMPACT LED FLOODS FOR ARCHITEC...

Страница 6: ...NSTALLATION 7650 FIRA INST ALL F IRA RANGE FLOODS All dimensions in mm Front view Fira Ultra Side view Rear view Top view Weights Fira Ultra Flood 4 5kgs Fira Pro Flood 4 4kgs Dimensions 212mm H x 175mm W x 106mm D Perspective view Fira Pro Fira Pro Fira Ultra COMPACT LED FLOODS FOR ARCHITECTURAL LIGHTING MECHANICAL DETAILS Fira Pro Fira Ultra ...

Страница 7: ...tional Mounting Plate An optional mounting plate is available to fit the Fira Pro Fira Ultra Top view Top view Side view MECHANICAL DETAILS Fira Pro Fira Ultra Hole details A Clearance for M10 fixings B Clearance for M8 fixings C Clearance for M6 fixings D M10 Stud for Standard Yoke All dimensions in mm Torque setting for M6 yoke bolts 3 5 Nm Fira Pro Fira Ultra COMPACT LED FLOODS FOR ARCHITECTURA...

Страница 8: ...sed B Not used in accordance with the instructions C The cable connections are not made according to our instructions if the unit is used in damp or wet environments D Repairs are made by unauthorised persons E The serial number label has been removed or defaced Pulsar s maximum liability shall not exceed the price paid for the product In the unlikely event of a fault occurring do not use without ...

Отзывы: