www.pulsar.pl
EN54-7A17
RED POWER
22
-
use the „<” or „>” buttons to display the „EPS” parameter
-
press „OK”
- The current status will be displayed
-
use the „<” or „>” buttons in order to set the delay time
0.10 - 10s (factory setting)
1.0 - 1min
10.0 - 10min
30.0 - 30min
- confirm by pressing "OK"
-
in order to return to the main menu, simultaneously press the „<,>” rightmost and leftmost
buttons
6.3.4.
Acoustic indication ON/OFF „bUZ"
.
Emergency situations that may arise during the operation of the PSU are
indicated acoustically. The frequency and number of signals depend on the type of event.
Table 11. Acoustic indication.
No.
Description
Event
1
1 signal every 10s, battery mode
230 V power failure
2
1 signal every 10s, mains
operation
Battery failure, undercharged batteries
3
2 signals every 10s, battery mode
Low battery level
4
Fast signals, battery mode
The PSU will be disconnected because of the battery discharge
5
Constant indication
PSU failure [see section 6.2.8]
-
simultaneously press the „<,>” rightmost and leftmost buttons on the LED panel
-
The „tSt” parameter will be displayed
-
use the „<” or „>” buttons to display the „bU2” parameter
-
press „OK”
- The current status will be displayed