Breakpoints
P610-P641 Level/Volume Breakpoints
These parameters are used to create a profile of the vessel when
P600
=
11
(
universal
linear
) or
P600
=
12
(
universal
curved
). You should enter
breakpoints in pairs, a reading for level and its corresponding volume. The
more pairs you enter, the more accurate the profile will be. In the case of
universal linear, then enter the level/volume at each of the points where the
vessel changes shape. In the case of the universal curved, enter values
around each arc tangent, as well as at the top and bottom.
You must enter at least two pairs, and you can enter up to 16 pairs.
Universal Linear (P600=11)
This volume calculation creates a linear approximation of the level/volume
relationship, and works best if the vessel has sharp angles between each
section.
Level
Vo
lu
m
e
You should enter a level/volume breakpoint for each place where the vessel
changes direction, and numerous where the section is slightly curved
(mostly linear, but has got a small arc). You can enter any number of pairs
between 2 and 16.
Содержание dBi Series
Страница 1: ...dBi Series Intelligent Transducer INSTRUCTION MANUAL ...
Страница 2: ......
Страница 4: ......
Страница 8: ......
Страница 16: ...Page 8 This page left blank intentionally ...
Страница 19: ...Page11 Front Thread Mount dBi 3 6 dBi 10 ...
Страница 28: ...Page 20 ...
Страница 29: ...Page21 ...
Страница 30: ...Page 22 ...
Страница 42: ...Page 34 ...
Страница 60: ...Page 52 This page left blank intentionally ...