Eventually  the  auxiliary  cross  should  match  the  point  of  impact,  with  the 
sight's reticle being held in the aiming point. 

To save display calibration parameters, keep the 

“MODE”

 button

 (

or 

(

23

)

 

RC button) pressed for two seconds 

display will show 

“OK”

 message; the 

image  of  the  target  centre  should  now  coincide  with  the  centre  of  the  of 
sight's reticle.

To restore factory settings, select 

“Yes”

 in the item        

“Default settings”

.

Parameters as follows are restored to factory settings: 

Operating  mode

 – 

“Forest”

;          

 

Image calibration  mode

 

– 

automatic;

Brightness  of menu symbols

  – 5; 

Display  calibration

  – 

coordinates  X=0, Y=0;

Magnification

 – 

x1;                        

Color  inversion

  - off;

Brightness  settings

  – 10;              

Contrast  settings

  – 6.

Note. 

Auxiliary menu items (

“Display calibration”

 and

 

“Default settings”

are only available when the unit is in attachment mode.

While holding the reticle in the aiming point, move the auxiliary cross to the 
point of impact with buttons 

“LEFT”

 

or

 

“RIGHT”

 (or RC buttons 

(22),(24)

. To 

switch movement direction from horizontal to vertical, press button 

“MODE”

 

or 

(

2

3)

  RC  button. 

Horizontal/vertical  travel  range  of  the  auxiliary  cross 

relative to the limiting frame is

 +/-10.

NOTES

Содержание CORE FXQ38

Страница 1: ...FXQ38 THERMAL IMAGING SCOPE FRONT ATTACHMENT COREFXQ50...

Страница 2: ...nn Exportbeschr nkungen je nach dem Gesetz in Ihrer Region unterliegen Atenci n La exportaci n de los modelos 76453 76459 con una frecuencia de 50 Hz puede tener restricciones de exportaci n seg n la...

Страница 3: ...ratures from 25 C to 50 C Degree of protection IPX5 IPX7 Compact size Low weight 2 Microbolometer characteristics Detector type Refresh rate Hz Pixel size m Resolution pixels Type Display Magnificatio...

Страница 4: ...ncreasing brightness and contrast level Decreasing brightness and contrast level Color inversion Menu navigation downards and leftwards Activating contrast control mode Activating brightness control m...

Страница 5: ...ectronic components inoperative The warranty does not cover damage caused by improper operation GUIDELINES FOR OPERATION 6 The unit has been designed for long term use To ensure sustainable performanc...

Страница 6: ...ired diameter depending on the outer diameter of the objective lens of the day device The figures 42 mm 50 mm 56 mm in adapter s model name correspond to the optical diameter of the lens of your day d...

Страница 7: ...c 8 correct wrong Having turned the unit on please make sure that the line of horizon of you day device is parallel to the upper and lower edges of the display of the CORE monocular It is recommended...

Страница 8: ...9 for two seconds to switch off the unit Other functions Calibration modes Please see section 8 Operation for details Press and hold down the MODE 12 button for two seconds to enter the menu Press bri...

Страница 9: ...e scope will void the warranty Clean the scope s optical surfaces only if necessary and use caution First remove by blowing with a blower brush or canned air any dust or sand particles Then proceed to...

Страница 10: ...ttings Operating mode Forest Image calibration mode automatic Brightness of menu symbols 5 Display calibration coordinates X 0 Y 0 Magnification x1 Color inversion off Brightness settings 10 Contrast...