Pulsar AWZG2 Series Скачать руководство пользователя страница 6

www.pulsar.pl 

                  Seria AWZG2                                                  

 

 

 

 

Fig.3. View of PSU. 

 

 
 
 

1.4.  Specifications:  

 
    - electrical specifications (tab.3) 
    - mechanical specifications (tab.4) 
    - operation safety (tab.5) 
    - operating specifications (tab. 6) 
 
 

Table 3. Electrical parameters. 
 
Models 

AWZG2-12V2A 

AWZG2-12V3A 

AWZG2-12V5A 

AWZG2-24V2A 

AWZG2-24V3A 

PSU type 

A (EPS - External Power Source),  

protection class 1

–2, II environmental class 

Supply voltage 

~ 230 V 

Current consumption 

0,23 A  

0,4 A 

0,6 A  

0,45 A 

0,7 A 

Power frequency 

50 Hz 

PSU power 

27 W 

41 W 

69 W 

55 W 

83 W 

Output current (max.) 

2 A 

3 A 

5 A 

2 A 

3 A 

Efficiency 

76% 

72% 

77% 

81% 

83% 

Output voltage 

11 - 13,8 V 

– buffer operation 

10 - 13,8 V 

– battery-assisted operation 

22 - 27,6 V 

– buffer operation 

20 - 27,6 V 

– battery-assisted 

operation 

Voltage adjustment 
range 

13 - 14 V  

27-28 V 

Ripple voltage (max.) 

10 mV p-p 

45 mV p-p 

30 mV p-p 

55 mV p-p 

55 mV p-p 

Current consumption by 
the PSU systems during 
battery-assisted 
operation 

11 mA 

10 mA 

11 mA 

14 mA 

14 mA 

Low battery voltage 
indication 

Ubat < 11,5 V, during battery operation 

Ubat < 23 V, during battery 

operation 

Charging current (jumper 
selectable) 

0,2/0,5A 

 

0,5/1A 

0,5/1/2A 

0,5/1A 

0,5/1A 

Содержание AWZG2 Series

Страница 1: ...USER MANUAL EN Edition 1 from 03 07 2020 Supersedes the edition _____ Power supplies AWZG2 series Buffer power supply unit Grade 2...

Страница 2: ...ion date Table of contents 1 Technical description 1 1 General description 1 2 Block diagram 1 3 Description of components and connectors 1 4 Specifications 2 Installation 2 1 Requirements 2 2 Install...

Страница 3: ...attery charging current should be set as follows Grade 1 2 standby time 12h The 12h standby output current can be calculated from the formula I QAKU 12 IZ gdzie QAKU minimum battery capacity Ah Iz PSU...

Страница 4: ...AUX DC power supply output AUX U AUX GND Description hi Z high impedance 0V connection to the ground GND LEDs AC indication of presence of main power LEDs AUX power supply output voltage indication LE...

Страница 5: ...12V5A 24V3A model Table 2 Elements of PSU see tab 3 Element no Description Isolation transformer Pcb of the PSU Tab 1 Fig 2 TAMPER micro switch of tamper protection NC L N 230 V power supply connecto...

Страница 6: ...uency 50 Hz PSU power 27 W 41 W 69 W 55 W 83 W Output current max 2 A 3 A 5 A 2 A 3 A Efficiency 76 72 77 81 83 Output voltage 11 13 8 V buffer operation 10 13 8 V battery assisted operation 22 27 6 V...

Страница 7: ...5A C AWZG2 12V5A D AWZG2 24V2A B AWZG2 24V3A C Enclosure dimensions W1xH1xD1 D 2mm 205x237x82 8 235x305x82 8 305x305 x105 8 335x385x173 14 205x305x82 8 335x385x173 14 Fixing WxH 175x202 205x272 274x26...

Страница 8: ...l an installation switch with a nominal current of min 3 A in the power supply circuits outside the power supply unit 1 Mount the PSU in a selected location and connect the wires 2 Connect the power c...

Страница 9: ...f AC supply is indicated by the AC diode going off LB red LED indicates the battery charging process AUX green LED indicates the DC supply status in the output of the PSU module Under normal status th...

Страница 10: ...Output current in standby mode for grade 2 EN50131 6 EN60839 11 AWZG2 12V2A B 2 A 0 58A AWZG2 12V3A C 3 A 1 41A AWZG2 12V5A C 5 A 1 41A AWZG2 12V5A D 5 A 3 33A AWZG2 24V2A B 2 A 0 58A AWZG2 24V3A C 3...

Страница 11: ...t the battery terminals A failure is indicated when voltage drops below approx 12 2 24 4 V 4 3 Maintenance Any and all maintenance operations may be performed following the disconnection of the PSU fr...

Отзывы: