10
7. Programming example.
This example shows how to program the time module to indicate whenever the doors in an air -
conditioned room are left open. The following assumptions are made :
- Allowable time for door opening: T1 = 1min 30s
- The minimum alarm time: T2 = 5s
The used program is PR14
„T1time activation delay and T2 time deactivation delay”.
1) Press the and buttons simultaneously for 5 seconds to enter
the programming mode.
The „PR” LED will blink and the number of currently saved
program will be displayed.
2) Use the for buttons to select the 14 mode.
Confirm by pressing the
„OK.” button.
3) The
„T1” and „h” LEDs are ON (time setting mode „T1”).
Press the OK button again to leave the zero value of the
number of hours.
4)
The „T1” and „m” LEDs are ON.
Use the for
buttons to set the „1”.
Confirm by pressing the „OK.” button.
5)
The „T1” and „s” LEDs are ON.
Use the for
buttons to set the „30”.
Confirm by pressing the „OK.” button”
6) Th
e „T2” and „h” LEDs are ON (time setting mode „T2”).
Press the OK button again to leave the zero value of the
number of hours.
7)
The „T2” and „m” LEDs are ON.
Press the OK button again to leave the zero value of the
number of hours.
8)
The „T2” and „s” LEDs are ON.
Use the for
buttons to set the „5.”
Confirm by pressing the „OK.” button.
9)
The scrolling message „ready” - indicating readiness for operation
of the module according to the PR14 mode and preset times
–
will be displayed.