background image

  1 

AWZ516 

v.2.1 

 

PC1 

Time relay module. 

 
 

                                                         Edition: 5 from 01.03.2018                                                     

EN*                                                                                              

 

    Supersedes the

 edition:

 4 from 15.01.2015                                                   

  
 

Features: 

 

 

 

10 

÷ 16V DC power supply 

 

18 time-logic programs 

 

The range of measured times: up to 100 hours 

 

High precision time measurements 

 

High load capacity of relay contacts  

 

LED display  

 

Three function buttons 

 

Activated by plus "S +" or mass "S-" 

 

Reset input activated by mass "R-"  

 

Optical indication of power supply and relay output status 

 

The possibility of implementing additional time-logic programs 

 

Warranty - 2 year from the production date 

 

 
 

TABLE OF CONTENTS. 
 
1.

 

General description. ....................................................................................................................................... 1

 

2.

 

Components arrangement. ............................................................................................................................ 2

 

3.

 

Programming the time module. ..................................................................................................................... 3

 

4.

 

Preview - the parameters of currently set program. .................................................................................... 4

 

5.

 

Previewing the status. .................................................................................................................................... 4

 

6.

 

Timer programs. .............................................................................................................................................. 5

 

7.

 

Programming example. ................................................................................................................................ 10

 

 
 

 
 

 

The time module is factory set to PR0 program mode with active REL relay. 

 

 

1.  General description. 

             The  PC1  time  module  is  a  transceiver  allowing  execution  of  time-logic  programs.  The  device  is 
characterized by versatility, high accuracy of the measured time based on the crystal oscillator and the possibility 
of its precise and repeatable adjustment. The relay can be used to extend short control impulses, e.g. controlling 
the  operation  locks,  electromagnetic  jumpers,  bistable  control,  etc.  The  relay  is  used  in  automation  and  control 
circuits and access control projects,

 

with logical dependencies on the state of: the controller, door opening sensor 

(reed switch), exit button, etc. 

Содержание AWZ516

Страница 1: ...amming the time module 3 4 Preview the parameters of currently set program 4 5 Previewing the status 4 6 Timer programs 5 7 Programming example 10 The time module is factory set to PR0 program mode with active REL relay 1 General description The PC1 time module is a transceiver allowing execution of time logic programs The device is characterized by versatility high accuracy of the measured time b...

Страница 2: ...e power supply ground R reset input activated by negative power supply ground LEDs optical indication red supply voltage REL ON relay on PR blinking programming mode ON previewing the current mode T1 time indication T1 T2 time indication T2 h hours indication 0 99h m minutes indication 0 59m s seconds indication 0 59s LED display Relay Buttons Decreasing the parameter move down one level in the me...

Страница 3: ...nd h LEDs are ON Confirm by pressing OK button 4 Use the or buttons to set the T1 time minutes The T1 and m LEDs are ON Confirm by pressing OK button 5 Use the or buttons to set the T1 time seconds The T1 and s LEDs are ON Confirm by pressing OK button 6 Use the or buttons to set the T2 time hours when required The T2 and h LEDs are ON Confirm by pressing OK button 7 Use the or buttons to set the ...

Страница 4: ...g the time module will be displayed The Preview Mode is disabled once the OK button is pressed again or after 5 seconds of inactivity 5 Previewing the status During normal operation it is possible to preview the time module operating status Press the or button the following information is displayed as follows Countdown timer hours The h and T1 or T2 LED is ON Countdown timer minutes The m and T1 o...

Страница 5: ... option single cycle The REL relay is activated automatically after switching on the power for the T1 time period Once the countdown of the T1 time is finished the REL relay is disconnected This mode is maintained until the power is disconnected In case of the S triggering signal rising edge during the countdown of the T1 time the module will lock and the relay will not be deactivated PR3 T1 to T2...

Страница 6: ... the REL relay is activated for the T2 time period This mode is repeated cyclically In case of the S signal level during the countdown of the T2 time the countdown is extended by the duration of the S signal The countdown is extended only during the countdown of the T2 time PR6 Deactivation delay with increasing T2 deactivation time with Ts time cyclic The countdown of the T1 time takes place auto...

Страница 7: ...al during the countdown of the T1 time rising edge resets and restarts the T1 countdown process PR10 Increasing the impulse to T1 time from falling edge The S triggering signal rising edge immediately activates the REL relay After a loss of the S signal falling edge the REL relay stays activated for the T1 time Another S triggering signal during the countdown of the T1 time will not affect the cou...

Страница 8: ...and T2 time deactivation delay The S triggering signal rising edge activates the countdown of the T1 time followed by the activation of the REL relay if the S signal is still on The relay stays activated for the entire duration of the S signal A loss of the S signal falling edge activates the countdown of the T2 time followed by deactivation of the REL relay If the triggering signal is shorter tha...

Страница 9: ...o T1 after detecting the rising edge and to T2 after detecting the falling edge The S triggering signal rising edge activates the countdown of the T1 time Once the countdown of the T1 time is finished the REL relay is deactivated A loss of the S signal falling edge activates the countdown of the T2 time followed by deactivation of the REL relay If the triggering signal is shorter than the T1 time ...

Страница 10: ...button 3 The T1 and h LEDs are ON time setting mode T1 Press the OK button again to leave the zero value of the number of hours 4 The T1 and m LEDs are ON Use the for buttons to set the 1 Confirm by pressing the OK button 5 The T1 and s LEDs are ON Use the for buttons to set the 30 Confirm by pressing the OK button 6 The T2 and h LEDs are ON time setting mode T2 Press the OK button again to leave ...

Страница 11: ...ams on demand Time ranges 0 1s 100h stored in the EEPROM memory Number of relays 1 Maximum switching voltage 250V AC 30V DC Maximum switching current 10 A The maximum contact resistance 100 mOhm Optical indication LEDs 7 segment double LED display Operating conditions II environmental class 10 C 40 C relative humidity 20 90 no condensation Dimensions L 120 W 43 H 22 mm 2 Mounting mounting tape or ...

Страница 12: ...uld be disposed of separately from normal household waste Waste electrical and electronic equipment must not be disposed of with normal household waste Pulsar Siedlec 150 32 744 Łapczyca Poland Tel 48 14 610 19 40 Fax 48 14 610 19 50 e mail biuro pulsar pl sales pulsar pl http www pulsar pl www zasilacze pl ...

Отзывы: