background image

 

EN 
1. General description. 

            

1.1. Destination. 

The 

AWT  027,

  transformer  is designed for the supply of equipment requiring the AC  voltage:  U1 or  U2, (electric 

strike, intercom). The power of devices connected to the terminals must not exceed the power of the transformer.

 

 

1.2. Electrical diagram. 

 

 

1.3. Description of elements and power supply connectors

 

 

 

 

 
 

 
 
 

2. Installation. 

 

The safety transformer must be installed by a qualified installer, holding the relevant certificates, required and 

necessary in the particular country for connecting (interfering with) the 230 V systems and low-voltage installations.  
 

           The transformer should be installed indoors (controls cabinets, casings), where air humidity is 
normal (RH=90% max. without condensation) and temperature in the range of -10°C to +40°C.  

 

1. Connect the transformer wires to the device.  

      Remarks:

 Connect the required voltage U1 or U2 for the device. The power of connected devices must not exceed 

the power of the transformer. 
2. Connect the transformer to 230 V outlet. The transformer should be installed in a manner and location that the flow of 

air around the transformer was free. 
3. Optionally perform other connections that are required for the type of device / system.  

      

Remarks:

 according to the requirements and  recommendations of the producer. 

4.

  

Start the system (switch on ~230 V), adjust or configure:  according to procedure of the producer’s system. 

 

3. Parametry techniczne / Technical data. 

 

Tab 1.

 

PARAMETRY 

TECHNICZNE 

TECHNICAL 

DATA 

 

Napięcie zasilania 

 

Power supply voltage 

230 V, 50Hz 

(-15%/+10%) 

Napięcie wyjściowe 

U1 lub U2 

Power supply voltage 

U1 or U2 

Tab. 2 

Prąd wyjściowy nominalny 

I1 lub I2 

Nominal output current 

I1 orI2 

Tab. 2 

Zabezpieczenie termiczne 

Thermal protection 

130°C powracalny  

ressetable fuse 130

o

Klasa szczelności 

IP degree 

                         IP 64 

Temperatura pracy / 

Klasa cieplna 

Operating temperature / 

Heat class 

-10ºC÷40ºC 

Ta 40B 

Wilgotność względna  RH – max. 

Relative humidity RH –max. 

90 [%] 

Element 

Description 

L-N 

Primary circuit connector,  230 V supply connector 

COM-U1-U2 

Secondary winding,  output voltage U1, U2 

ressetable fuse 130

o

Отзывы: