1. Destination: 

EN 

 

The 

AWO269PU

 metal casings 

compliant with EN50131 GRADE3

 are designed as components (supplying) in 

intruders alarms, access control systems, security systems etc. There are intended for installation: 

 

control panel optional with supplementary modules 

 

access control controllers with optional modules  

 

radio or GSM transmitter with optional module PSU 

 

other dedicated devices, components etc. 

 
2. Installation:  

 

 

The metal casing (+PCB) must be installed by a qualified installer, holding the relevant certificates, required and 

necessary in the particular country for connecting (interfering with) the 230 V AC systems and low-voltage installations.  

Because the transformer is designed for the continuous operation and is not equipped with ON/OFF switch, the 

power supply line should have the appropriate overload protection. The user should be informed how to disconnect the 
unit from the mains (the most often by separate and mark the adequate fuse in the fuse box). The power supply 
installation should be conform to the applicable standards and law.  

The casing (+PCB) should be installed indoors, where the air humidity is normal (RH=90% max. without 

condensation) and temperature in the range of -10°C to +40°C. 

 

 

 

Caution!      Prior to entering for installation it is necessary to make sure if the voltage 

in the 230 V/AC circuit is disconnected. 

All service works inside the housing must be carried out with 230V/AC supply voltage 

disconnected. 

 

 
1. Mount the PCB (control panel, etc) with dedicated holes (use distance pins, bracket screw). 

2. Install metal casing in dedicated place and bring in the connecting (~230V) and signal conductors through cables 
bushings. 

Remarks: 

supply circuit ~230V should be carried out with three-core cable  

(with yellow-green protective PE conductor). 

3. Supply conductors ~230V should be connected to 

230V / AC L-N

 terminals of the transformers. 

Protective conductor should be connected to the terminal marked with grounding symbol.   

 

                  
                    Caution!      Operating the power supply without properly made and technically 

      operational electric shock protection circuit is IMPERMISSIBLE! 

        This creates hazard of equipment damage and risk of electric shock. 

 

 

 
4. Connect the output of transformer to the terminals (~AC) on the PCB, using installed cables 

Remarks: 

connect required voltage U1 or U2 (secondary voltage) for the correct device. 

5. If necessary, make other connections required for the correct type of system / device. 

Remarks: 

consistent with requirements and recommendation of the producer. 

6.

  Start the system (switch on ~230V, battery), adjust or configure: according to procedure of the 

producer’s system. 

7. After installing and checking the proper operation of the system, close the casing. 

 
 

 
 

 
 
 

 

 
 
 

Содержание AWO 269PU

Страница 1: ...zepisów Obudowa PCB powinna być montowana w pomieszczeniach zamkniętych o normalnej wilgotności powietrza RH 90 maks bez kondensacji i temperaturze z zakresu 10 C do 40 C Przed przystąpieniem do instalacji należy upewnić się że napięcie w obwodzie zasilającym 230V AC jest odłączone Wszelkie prace serwisowe wewnątrz obudowy należy wykonywac przy odłączonym zasilaniu 230V AC 1 Zamontować w obudowie ...

Страница 2: ...for installation it is necessary to make sure if the voltage in the 230 V AC circuit is disconnected All service works inside the housing must be carried out with 230V AC supply voltage disconnected 1 Mount the PCB control panel etc with dedicated holes use distance pins bracket screw 2 Install metal casing in dedicated place and bring in the connecting 230V and signal conductors through cables bu...

Страница 3: ...1 lub U2 lub U3 I1 lub I2 lub I3 F t AWT682 TRZ 60 18 20 PC ABS UL 94 V 0 IP43 60VA 230V AC 0 33A 18V lub 20V 3 3A lub 3 0A T 500mA 250V 130 o C AWT5161820 TRZ 50 16 18 20 PC ABS UL 94 V 0 IP43 50VA 230V AC 0 25A 16V lub 18V lub 20V 3 0A lub 2 8A lub 2 5A T 500mA 250V 130 o C AWT5172430 TRZ 50 17 24 30 PC ABS UL 94 V 0 IP43 50VA 230V AC 0 25A 17V lub 24V lub 30V 2 9A lub 2 1A lub 1 7A T 500mA 250V...

Страница 4: ...wy The lower part of the housing 1 INT E x 6szt max 2 INT PP x 3szt max 3 INT IORS INT ORS x 2szt max po zastosowaniu zestawu szyny DIN AWO269S After using the AWO269S din rail kit 4 Transformator i akumulator 7Ah 17Ah 5 Zasilacz APS 612 lub APS 412 i akumulator 7Ah 17Ah Ogólne warunki gwarancji Ogólne warunki gwarancji dostępne na stronie www pulsar pl ZOBACZ PRODUCENT PRODUCER Pulsar Siedlec 150...

Отзывы: