background image

 

2. Mounting of the ARAS800/1000 rail in the RACK 19” cabinet: 
 

         Mount cage nuts for M6 screws in the RACK cabinet, as shown in Figure 2 below, and mount the ARAS rails 

(depending on the depth of a RACK cabinet). Make sure that the rail is correctly mounted horizontally and its length 
between the front and rear RACK profile is properly adjusted.

    

 

 

 

Fig.2

  

3. Mounting of the ARAD-S4 in the RACK 19” cabinet:

 

 
After mounting the ARAS rails in the rear of the RACK 19 ", mount the Patch Panel as shown in Figure 3. 
 

 

  

Fig.3 

 

Mount the ARAD-S4 enclosure on fully extended ARAS rails using 6xM4 screws (complete with ARAS rails). 

Tighten the screws from the inside. Connect the Patch Panel wires as shown in the Fig.4 

 

CAUTION!!! - Pay attention to the correct arrangement of    A / B / C / D / E / and F connectors 

in the appropriate sockets described on PCB Signal Boards. 

 

 

 

Fig.4 

Содержание ARAD-S4

Страница 1: ...ith a space for 17Ah battery transformer and the ARAW45 fan transformer and fan are not included Both ARAS800 and ARAS1000 rails selected depending on the depth of a RACK cabinet constitute the load bearing part of the enclosure not included The enclosure is fitted with 6 printed circuit boards PCB allowing connection of signal power and control cables Each of the boards has 8 pairs of terminals d...

Страница 2: ...ile is properly adjusted Fig 2 3 Mounting of the ARAD S4 in the RACK 19 cabinet After mounting the ARAS rails in the rear of the RACK 19 mount the Patch Panel as shown in Figure 3 Fig 3 Mount the ARAD S4 enclosure on fully extended ARAS rails using 6xM4 screws complete with ARAS rails Tighten the screws from the inside Connect the Patch Panel wires as shown in the Fig 4 CAUTION Pay attention to th...

Страница 3: ...64 Protective tube for signal cables 24 YTDY 6x0 5 wires internal external diameter ø21 ø29 available as accessory MM020 The routing of protective tubes in the Patch Panel and its sealing is shown in the Fig 5 Fig 5 The ARAD S4 enclosure is fitted with 3 tamper switches 1 Pulling out the enclosure from RACK profiles 2 Enclosure opening 3 Patch Panel opening The enclosure is mounted in the front of...

Страница 4: ... PCB supply 230VAC max 5A PCB Power Board in the Patch Panel PCB Power Board in a retractable housing PCB Signal Boards Single PCB Signal Board allows connecting up to 8 signal supply lines The maximum operating conditions of a single line 30VDC 1 5A PCB Signal Board in the Patch Panel PCB Signal Board in a retractable housing ...

Страница 5: ...5 5 Additional equipment Space for 17Ah battery TRP TRZ 20 80VA transformer ARAW45 fan 230VAC board with the F3 15A melting fuse 6 Dimensioning Mounting plate Hinged mounting plate ...

Страница 6: ...UB2 RISCO PRO24 PRO116 PRO128 PRO140 5 x EZ04 EZ8 EZ16 RP296EPS SATEL CA4V1 CA5 CA6 CA10 VERSA5 10 15 INTEGRA24 32 64 128 CA64 PTSA CA64 PP 5x CA64E CA10E PP EPS ADR O R O ROC O OC OPS OC OPS R OPS ROC VGM 16 SR PTSA PYRONIX MATRIX 424 832 832 TEXECOM PREMIER412 816 832 48 88 168 640 TELMOR TCA 824 5 x TEX800 TMT1 ROGER PR402 CPR 32 SE EBS PX 202A PULSAR 5x MS1012 MSR1012 MSRK1012 5x MS2012 MSR201...

Страница 7: ...eight 14 15 kg Finish steel plate 1 1 5mm color black RAL 9004 Application Indoor Notes The enclosure is mounted using the ARAS800 1000 rails depending on the depth of the RACK 19 cabinet 4xM6 screws butt mounted to RACK profiles Patch Panel mounting 8xM6 butt mounted to RACK profiles 2xM6 to ARAS800 1000 rails The set includes protective tube MM020 ø21 ø29 0 5m 2 pieces protective tube MM064 ø6 ø...

Отзывы: