Troubleshooting
☐
The device does not turn on
Possible cause
The Battery Pack is empty.
Solution
Charge the battery pack.
☐
The device does not operate on external power supply
Possible cause
USB cable is damaged.
Solution
Replace USB cable.
Possible cause
The external power supply is discharged.
Solution
Charge the external power supply.
☐
The image is blurry, with vertical stripes and uneven
background
Possible cause
Calibration is required.
Solution
Carry out calibration according to
section.
☐