1
2
3
4
5
SPECIFICATIONS
•If your Puleida PU-300 does not operate normally, please refer to the following table
for a possible cause and solution.
•If the following troubleshooting solutions do not work, please contact us for help. Refer
to the last page of User Guide for contact information.
MAINTENANCE
FREQUENTLY ASKED QUESTIONS
LCD Screen Display
Possible Causes
Solutions
F: Why doesn’t my Puleida PU-300 power other devices?
Q:
First, make sure the output ports have been turned on by pressing the corresponding Port
On/Off Buttons. Then, check the battery level of the unit. Please recharge the unit as soon as
possible. Finally check if the connected device conforms to the specifications of output ports. If
the unit still cant power your devices, see TROUBLESHOOTING or contact us for help. Refer to the
last page of User Guide for contact information.
F: Can I replace the battery pack in my Puleida PU-300?
Q:
No, the battery pack in Puleida PU-300 is not replaceable. Do not try to dismantle your Puleida
PU-300 and replace the battery by yourself. Doing so may cause irreversible damages to the unit
and battery explosion.
F: Can Puleida PU-300 be interconnected ?
Q:
No, the Puleida PU-300 can NOT be interconnected with other power stations. If you are
looking for a rechargeable AC power supply with larger capacity, please visit our official website or
contact us for more options. Refer to the last page of User Guide for contact information.
F: Is the Puleida PU-300 waterproof?
Q:
No, the Puleida PU-300 is not waterproof. Please keep the unit away from moisture. Do no
submerge the unit in water or operate the unit in the rain. Doing so may cause short-circuits,
electric shocks, and fire.
F: Why doesn’t the battery of Puleida PU-300 last as long as I expect?
Q:
The battery capacity is rated at 0.2C.When the Puleida PU-300 is powering devices that have
high power consumption, the internal resistance of battery will turn more energy into heat and
lower battery capacity as a result. When this is the case, you may not get exactly 296Wh of
energy.
•
Puleida products are covered by a 24-month limited warranty from the original purchase date. If
any problems occur, please contact us for assistance. Refer to the last page of User Guide for
contact information.
•
We only provide after-sales services for products that are sold by Puleida or retailers and
distributors authorized by Puleida. If you have purchased your unit from other channels, please
contact your seller for more information about return and warranty policy.
•
Please register your purchase(s) directly at www.ipuleida.com so that we can stay in touch and
contact you.
DC input interface
over-voltage
protection/under-voltage
protection
(Unsuitable power adapter or
power input supply
)
Corresponding interface
triggers short-circuit
protection
·1.There is a problem with the output
port corresponding to the flashing light
·2.After removing the corresponding
device, restart and use the device
normally
·3.Check the parameters of the
electrical equipment are within the
energy storage adaptation range
(
Check the rated current and rated
voltage of the device
)
·4.Restart and use the device normally
-------------------
If the device cannot be used normally
after reconnecting it, you need to
confirm whether there is a problem
with the wire or the electrical device
has a short circuit.
·A.When the product is not connected
to the device, the output is normal.
·B.Connect the wire separately, if the
product protection is triggered, there is
a problem with the wire.
·C. If the product protection is not
triggered by connecting the wire alone,
and the protection is triggered by the
connecting device, there is a problem
with the device.
Corresponding interface
triggers over-current
protection
AC indicator and output Err
flashing at the same time
Triggering AC part high
temperature protection
The battery temperature is
not within the safe working
temperature of the product
during charging or
discharging.
Input OTP Flashing
AC/DC/TYPE-C/USB Lights
on
"OUTPUT Err" Flashing
Output OTP Flashing
NO output can be operated
when Power light indicates
0%
Battery under-voltage
protection
Still the product to cool till it
goes back to the room
temperature.
Recharge the power station
"INPUT Err" Flashing
1. Please use the AC Adapter
provided by Puleida to charge the
powerstation.
2.Please use the PD charging
adapter or solar modules with an
output voltage of 10-25V.
12
13