Installation:
CAUTION: Possibly hazardous optical radiation emitted from this product. Do not stare at operating lamp. May be harmful to the eye.The
replacement must be done by a qualified electrician.
Recommendations
1) verify that the equipment used to connect our devices to enjoy all the guarantees required under European law
2) use the cables, connectors and quality materials for electrical wiring;
3) Products with IP65/68 degree make the wiring / connections with accessories provide the same degree IP of the selected product
(available in the catalog);
4)Disconnect main voltage during installation and maintenance
5)
It is essential to do a frequent cleaning of the glass and of the outer surface of the fixture to avoid build up of mud and dirtiness resul-
ting in dangerous overheating due to uncorrect light and heat dissipation. Clean carefully the glass screen removing limestone deposits
by means of a scraper.
Disconnect main voltage during installation and maintenance
1)Drill hole on the edge of the pole suitable at the point of supply 25mm to the top (pic1)
2) Remove the bracket of the luminaire unscrewing the two lateral screw by using an hexagonal tool (pic 2)
3) Assembling the semicircular adapter to the bracket as shown in figure (pic 3)
4) Plug the adapter with the bracket to the pole (pic4)
5) Fix the adapter with the bracket to the pole in the hole previously drilled using the hex key (pic5)
6) Plug the power cable through the hole of the bracket and the pole (pic6)
7) Fix the luminaire to the bracket
8) Adjust the vertical and horizontal inclination using the hexagonal screw drive by acting on the screws of the brackets (pic8)
9) For poles with 60 mm in diameter using the plastic adapter as in picture 9
10) For electrical connection of the pole connectors follow the general safety rules. Is a Class 1 should be connected to the grounding
device