Pujol SENIOR 1 Digital Series Скачать руководство пользователя страница 14

ENG

ENG

Digital Adjustment of operating times, automatic close and smooth stop.

Before starting to programme the times, disconnect from the mains and ensure that: 

All the connections have been made correctly.
All the options switches are OFF except for I4 that must be ON.
The door is fully closed.
If you want smooth stop at the end of the operation, turn I5 to ON 

Once the above points have been reviewed, connect the circuit to the mains and start programming the opening, 
automatic close standby and closing times.  To do so, proceed as follows: 

Press the programming button until the programming led comes on. The led will flash while the times are being 
programmed. 

2.A  Enable the start button using the transmitter or the test button. The door will begin to open. 

2.B If you require the 'smooth stop' option, I5 must be ON. Wait for the door to open past the point where the 
'smooth stop' is to begin and then press the start button or the remote control and the motor buffering will begin. 
The opening buffering time will be memorised. 

Once the required opening point is reached, stop the door by pressing the start button or wait for it to stop 
automatically if the opening limit switch is connected. 

The standby time for automatic close will then begin to be counted. After the required time, press the start button 
again and the door will begin to close. 

5.A If you require the 'smooth stop' option, I5 must be ON. Wait for the door to close past the point where the 
'smooth stop' is to begin and then press the start button or the remote control and the motor buffering will begin. 
The closing buffering time will be memorised. 

Once the door has closed, press the start button again or wait for the door to stop automatically if you have the 
closing limit switch connected.  The programming led will switch off and programming will be complete. 

Operating

a)       Normal operating.
Automatic operations are carried out using the start button (button TEST C.I. plaque, P.ALT terminals button or with the 
radio card.
The operation stops in either of the following conditions: the pressing of the corresponding FC or completing of the 
operating period.
If an order is given during the opening operation the operation will end and the door will not close automatically.
If an order is given during the closing operation this will inverted and the door will open.

Pressing C.SEG during the closure operation will invert the operation, opening the door.

The Garage Light Contact enables the start of the opening operation and disables 2 seconds after the start.

The  power  adjustment  of  the  motor  selected  using  the  POWER  switch  is  applied  2  seconds  after  the  start  of  the 
operation.

b)       Pedestrian Opening
If the door is completely closed it can be partially opened for pedestrians using button P. Open. The door will open for a 
period of 5 seconds.

Memory code channel

The control panel should be in a stable position, door open or closed, to memorise the channel codes.

a)  Memory manual

To memorise a code, press programming button PROG/RES for 1.5 seconds. The red Led will come on and will remain 
lit, indicating preparation to memorise the code.

Single-phase panel with power adjustment. Luminous inlet indicators. Outlet to activate soundless electric lock. 
Optional smooth stop. Radio incorporated with possibility of 253 different channels.
Possibility of digitally programming times (the operating time potentiometer must be at a minimum for the panel to 
operate with digital times). 

Installation.

Make sure that the power is disconnected before proceeding with installation.

Description Bornes.

Power                                                                Operation
1   220Va.c feed                                                8  Outlet 12V dc 125mA
2   220Va.c feed   

      9  O V (common pedestrian)

3   Motor opening

      10  Pedestrian opening button.(N.A.)

4   Motor closing

.                                       11  Common contact limit switch.

5   Common motor

      12  Closing limit switch N.C.

                                                                                (Mark between FCC-FCA (11) and FCC (12) if not in use)
6   Voltage-free garage light

      13  Opening Limit switch N.C.

                                                                                (Mark between FCC-FCA (11) and FCA (13) if not in use.)
7   Voltage-free garage light

      14  Safety Contact (NC)

                                                                                (Mark between C.SEG (14) and Mass (15) if not in use.)
                                                                          15  Common for buttons
                                                                          16  Start button N.O.
N.B: N.O., Normal Opening

      17  Electric Lock 12 V

         N.C., Normal Closing

      18  Electric Lock 0 V

Selection of Options.

Select the options with micro-switches.

(1). If switch I2 is ON, the panel will order maximum power for 3.5 seconds on completing the closing operation to 
make sure the door is closed properly. 
(2). If the panel is operating with digital times, switch I4 is also used for selection if times ( I4 ON)  or transmitters ( 
I4 OFF) are to be programmed with the programming button.

TIMERS.

Automatic Closing Time .

Working Time.

             Motor Power. 

          T.BAJ.AUT.

    T.FUNC.

                FUERZA

 

 

 

3 seg

120 seg

3 seg

60 seg

Less

More

I 1 Automatic closing 

ON: The door closes automatically when the time programmed with the 
         potentiometer has passed. 
OFF: No automatic closing. 

I 2 Inversion stroke 
               (1) 

ON: Leave the door for 3 seconds before giving the order to open 
OFF: Door opens normally.      

I 3 To stop closing 

ON: If the start button is pressed the door will not open 
OFF: If the start button is pressed when the door is opening  
        it will stop. 

I 4 Photocell closing 
              (2) 
 

ON: If the photocell is enabled when the door is opening or is 
        open it will give the order to close. 
OFF: The photocell will not give the order to close. 

I 5 Smooth stop 

ON: The door will close smoothly for the last 7 seconds of the operation. 
OFF: No smooth stop. 

 

https://appceso.com

Содержание SENIOR 1 Digital Series

Страница 1: ...cnico Post Venta Service Technique Apres Vente Servizio Tecnico Post Vendita After Sales Technical Service Servi o T cnico Pos Venda Technischer Kundendienst Service FRANCE PUJOL MUNTAL FRANCE S A R...

Страница 2: ...os el interruptor I2 ON al acabar la maniobra de cierre el cuadro da la m xima potencia durante 3 5 segundos para asegurar que la puerta quede bien cerrada 2 Si el cuadro funciona con tiempos digitale...

Страница 3: ...ador alternativo o autom ticamente se parar si tenemos unfinaldecarreradecierreconectado Elleddeprogramaci nse apagar yfinalizar laprogramaci n Funcionamiento a FuncionamientoNormal Las maniobras del...

Страница 4: ...posterior y el emisorse grabaautom ticamenteenelreceptor cuadro Lagrabaci ndelCPF es temporalysedesactivasi pulsamosm sde20veceselemisor Anulaci n detodos los c digos Laanulaci ndetodoslos c digossec...

Страница 5: ...in einer Steuerung zu speichern die schon einen CPF besitzt mu man nur den r ckseitigenTasteraktivieren undderSenderwirdautomatischimEmpf nger Steuerung gespeichert Die Speicherung eines CPF ist zeit...

Страница 6: ...halten werden bzw h ltdasTor automatischan fallseinWegendef r das ffnenangeschlossenist 4 Ab diesem Moment beginnt die Wartezeit f r den automatischen Verschlu Die gew nschte Wartezeit wird mit dem Be...

Страница 7: ...secondes du commencementdelamanoeuvre b Ouverturepi tonne Acondition que la porte soit totalement ferm e gr ce au bouton P Ouvrir on pourra effectuer une ouverture partielle de laportepourlepassagede...

Страница 8: ...omatiquementdans ler cepteur cadre L enregistrementduCPFest temporaireetsed sactivesionappuy plusde20foissur l metteur Annulation detous lescodes L annulationdetous lescodess obtientgr ce un reset del...

Страница 9: ...orridos 10 segundos desde a ltima recep o de um c digo apagando se ent o o Led indicador vermelho poss vel abandonar o modo de memoriza o antes de tempo pulsando a fun o especial de um dos emissores m...

Страница 10: ...me araprogramaros tempos desconectarocircuitoderedeparacomprovaros seguintes pontos Todas as liga esforamrealizadascorrectamente Todos os selectores seencontramna posi oOFF exceptooselectorI4 que deve...

Страница 11: ...desiderato si render necessario arrestare la porta attivando il pulsante alternativoosiarrester inmanieraautomatica se stato collegatoun finecorsadiapertura A partire da questo momento comincer a cont...

Страница 12: ...esta memoria o meglio memorizzandolaprimaemittentecheposseggailCFPessendolamemoriadelricettorevergine Per registrare un emittente con CFP in un quadro che abbia il CFP dobbiamo solo attivare il tasto...

Страница 13: ...off Exitcanbemadebeforetimepressingthespecialfunctionofoneofthememorizedchannels C MemorizationviaradiowithEasyProgrammingCode To use this system it is necessary that the memory of the receiver has th...

Страница 14: ...the operation b PedestrianOpening If the door is completely closed it can be partially opened for pedestrians using button P Open The door will open for a periodof 5seconds Memorycodechannel Thecontr...

Отзывы: