![PTN TPHD405PT-WPI Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/ptn/tphd405pt-wpi/tphd405pt-wpi_user-manual_1623446011.webp)
Scaler Wall Plate HDBaseT Transmitter
PTN Electronics Limited 7 www.PTN-electronics.com
monitoring, conference room, big screen displaying, television education, command &
control center and smart home etc.
4. Control Modes
4.1 IR control
TPHD405PT-WPI provides an IR IN/ IR OUT socket for connection to IR receiver/ IR
Transmitter to attain bi-directional IR transmission with the far-end receiver.
Control far-end device from local
Control TPHD405PT-WPI or far-end display device from local by the IR remote of
far-end display. IR control signal will be received by IR IN socket, and converted to
corresponding IR output socket of the far-end receiver.
Control local device from remote
Control local source device from remote via corresponding IR remote. The control signal
will be transmitted via the IR OUT socket.
4.2 RS232 Control
As RS232 can be transmitted bi-directionally between TPHD405PT-WPI and
TPHD402PR, so it is able to control a third party RS232 device from local or control
TPHD405PT-WPI from remote.
4.2.1 Installation/uninstallation of RS232 Control Software
When to control a third party RS232 device, the baud
rate of this device should be 2400, 4800, 9600, 19200, 38400, 57600 or 115200.
Installation:
Copy the control software file to the computer connected with
TPHD405PT-WPI.
Uninstallation:
Delete all the control software files in corresponding file path.
4.2.2 Basic Settings
First, connect TPHD405PT-WPI with all input devices and output devices needed, then
to connect it with a computer which is installed with RS232 control software.
Double-click the software icon to run this software.
Here we take the software
CommWatch.exe
as example. The icon is showed as below:
The interface of the control software is showed as below: