PTF PEPPER PTF 4 Скачать руководство пользователя страница 2

Information on the foil tunnel

Follow the OHS Rules

2

Wear protective gloves

during the assembly

Wear protective glasses

during the assembly

Provide help from the 

assistant  during the assembly

The temperature 

in the tunnel is high

Perform assembly 
on days which are not windy

It is prohibited to have 
the structure assembled 
by drunk and intoxicated personnel

 

Thank you that you have chosen PTF Polska tunnel. We believe that it will help you in growing your flowers and vegetables and that you will be satisfied a lot. 

We did our best so that the design and modern technical solutions are helpful in the cultivation and so that the assembly is simple and easy.

WARNING!

PTF POLSKA foil tunnels are not suitable for assembly in open spaces or locations where the structure will be exposed to strong winds. They must be assembled 
in a place protected against wind and not exposed to it directly – this will prevent its damage.

Do not leave the foil on the tunnel in the winter period because it may be damaged due to the pressure of snow.

Do not tie up the shrubs with crops to the framework (e.g. tomatoes) – this may impair the structure greatly.

Safe use rules:
1. The tunnel is dedicated only to plant growing.
2. Dig the foil excess in the ground – this will prevent the tunnel from being caught by the wind.
3. Mount the structure in the place not exposed to strong wind blows; avoid slopes and open spaces.
4. Do not assemble the tunnel in strong winds and in other adverse weather conditions.
5. Keep children away from the assembly site because the set includes small elements and foil bags which may lead to choking or suffocating.
6. Check the stability of the tunnel regularly, especially after storm winds. If you notice any damage, replace a damaged element or disassemble the structure.

7. Use assembly tools specified in the manual and wear protective gloves and glasses during the tunnel assembly and maintenance.

8. Avoid using mowers and mechanical scythes near the structure.
9. Do not keep hot objects, especially hot barbecue equipment, etc. in the tunnel.
10. Remove the foil from the tunnel for the winter season and secure the structure so that it is not caught by the wind.
11. Do not climb the structure roof.
12. Do not leave children unattended in the tunnel because the door may close and prevent children from exiting the structure.

13. Do not use open flame in or near the structure. 

14. Do not load roof panels additionally (with the exception of tied-up plants).
15. The tunnel cannot be used in the public space.

Содержание PEPPER PTF 4

Страница 1: ...Assembly manual PEPPER PTF 4 Foil tunnel Scan to see the assembly video...

Страница 2: ...es 1 The tunnel is dedicated only to plant growing 2 Dig the foil excess in the ground this will prevent the tunnel from being caught by the wind 3 Mount the structure in the place not exposed to stro...

Страница 3: ...1 x4 Z 08 x6 P 02 x8 720mm P 05 x4 750mm P 08 x26 980mm P 04 x10 1050mm P 06 x4 1550mm P 03 x10 1300mm SZ 1 x8 Z 11A x12 List of elements CHECK WHETHER THE PACKAGING INCLUDES ALL THE ELEMENTS We recom...

Страница 4: ...8 x4 x4 List of elements CHECK WHETHER THE PACKAGING INCLUDES ALL THE ELEMENTS We recommend elements sorting before their assembly This will facilitate assembly works HINGE x4 FOIL 2 x2 FOIL 1 FOR THE...

Страница 5: ...x1 DRILL DRIVER x1 MEASURING TAPE x1 SCISSORS x1 RUBBER HAMMER x1 SCREWDRIVER x1 12mm DRILL x1 SPANNER 8 x1 The DIY assembly foil tunnel lacks some tools Provide necessary tools before starting work T...

Страница 6: ...P 08 x8 980mm Z 05 x6 Z 01 x4 elements 1 Hammer in the pro les with a rubber hammer not a steel one...

Страница 7: ...Z 05 x4 P 05 x2 750mm elements 2...

Страница 8: ...P 07 x4 570mm elements 3 SZ 1 x8 HAMMER IN THE ANCHORING ELEMENT SZ 1 INTO THE GROUND...

Страница 9: ...P 03 x10 1300mm elements 4...

Страница 10: ...5 elements Z 11A x6 About 710 mm from the ground to the connector Z 11A...

Страница 11: ...6 Z 08 x6 elements...

Страница 12: ...7 elements Z 06 x2 Z 07 x2 A B A A B B...

Страница 13: ...8 P 06 x4 1550mm elements...

Страница 14: ...9 elements Z 11 x4...

Страница 15: ...10 P 05 x2 750mm elements...

Страница 16: ...elements 11 P 08 x8 980mm...

Страница 17: ...12 P 04 x4 1050mm elements...

Страница 18: ...13 elements Z 09 x2...

Страница 19: ...14 x3 P 04 x6 1050mm Z 11A x6 Z 10 x3 elements...

Страница 20: ...15 elements x3 2...

Страница 21: ...16 elements P 08 x4 980mm A B B B A A A...

Страница 22: ...17 P 08 x6 980mm elements...

Страница 23: ...18 elements W1 x132 BIT x1 All the pro les and connectors of the foil tunnel must be screwed with W1 screws Do not mount the screws on the external side of the tunnel to prevent foil damage...

Страница 24: ...x2 elements 40cm ground foil All Z 14 clips must be fastened with W1 screws from the inside of the tunnel DO NOT CUT OUT THE FOIL EXCESS Dig it into the ground at the depth of 40 cm The foil should b...

Страница 25: ...20 Z 05 x4 20 x2 P 02 x8 720mm P 01 x6 680mm Z 03 x8 elements A B B B A A B B A...

Страница 26: ...x2 elements 21 x1 W1 x28 Place the screws evenly BIT Connect the pro les and connectors by means of W1 screws...

Страница 27: ...22 elements FOIL 1 x2 Z 14 x24 x2 All Z 14 clips must be fastened with W1 screws from the inside of the tunnel...

Страница 28: ...1 1 2 2 3 x4 23 x2 BIT x1 elements HINGE W1 x8 x4 ZMC x4 x4 12mm DRILL SCREWDRIVER x1 SPANNER 8 x1 1 2 3 12mm DRILL Hinge assembly...

Страница 29: ...24 W2 x8 x2 elements x1 W1 x8 x4 x1 W2 x8 W1 x8 BIT SCREWDRIVER...

Страница 30: ...25 elements FOIL 3 x1 1 2...

Страница 31: ...26 elements BIT x1 W1 x8 1 2...

Страница 32: ...40cm 27 40cm 40cm ground foil DO NOT CUT OUT THE FOIL EXCESS Dig it into the ground at the depth of 40 cm The foil should be folded in the ground...

Страница 33: ...28...

Страница 34: ......

Страница 35: ......

Страница 36: ...PTF Polska ul Nowozach ty 14 41 407 Imielin POLAND phones 48 32 223 11 86 48 503 085 265 e mail biuro tunelefoliowe eu...

Отзывы: