background image

1. Before each use, inspect the general  

 condition of the tool.

Check for:

  •   Loose hardware

 •   Misalignment or binding of moving parts

  •   Damaged cord/electrical wiring

  •   Cracked or broken parts

  •    Any other condition that may affect its safe 

     operation.

2.  After use, heat up the soldering tip again and  

 apply a small amount of rosin-core solder  

 to coat the tip. Wipe off with a rag. This will 

leave the tip clean and ready for use.

3. If the soldering tip cracks or becomes eroded, 

it needs to be replaced:

   A. Using wrench, loosen the soldering tip  

 nutsby turning counter clockwise.

  B. Pull the old soldering tip out of the   

 transformer assembly mounting posts. 

   C. Slide the ends of the new soldering  

 tip into the mounting posts of the   

 transformer assembly.

  D. Carefully tighten the nuts over the  

 mounting posts by turning clockwise

  Make sure that the nuts fit squarely  

 over threads or damage will occur to  

 the mounting post threads. Do not  

 overtighten.

4. To replace the light bulb:

   A. Remove the light bulb lens from the    

 front of the soldering gun.

  B. Pull out the burnt light bulb and 

replace with a new one of the same  

 voltage and type. See specifications on 

Page 3.

   C. Replace the light bulb lens.

WARNING! If the supply cord of this power

tool is damaged, it must be replaced only by

a qualified service technician.

5

6. Brush on solder flux, as needed, to the 

workpiece. Place the Soldering Tip to the 

joint, wiring splice, or metal to be soldered.

7. Apply solder to the wire splice or metal to 

be soldered, not the Soldering Tip. When 

the splice or metal is hot enough, it will 

melt the solder causing it to flow within 

the splice or between the metal surfaces.

8. When the solder has flowed over the en-

tire wire splice or metal surface, remove 

the Soldering Tip and release the Trigger.

9. To prevent accidents, turn off the tool 

and unplug it after use. Clean, then store 

the tool indoors out of children’s reach.

WARNING! To prevent serious injury from accidental operation: Make sure that the trigger 

is in the off position, unplug the tool from its electrical outlet, and allow it to cool completely 

before performing any procedure in this section.

WARNING! To prevent serious injury from tool failure: Do not use damaged equipment  

if abnormal noise or vibration occurs, have the problem corrected before further use

WARNING! To prevent serious injury from accidental operation: Make sure that the trigger 

is in the off position and unplug the tool from its electrical outlet before performing any 

procedure in this section.

MAINTENANCE

OPERATING INSTRUCTIONS & SET UP CONT.

Содержание W2012

Страница 1: ...mance or reliability nor shall these warranties apply to any product or part which has been subject to misuse neglect accident or wear and tear incident to normal use and service PERFORMANCE TOOL does...

Страница 2: ...OLDERING GUN Item Number W2012 WARNING READ UNDERSTAND AND FOLLOW ALL INSTRUCTIONS AND WARNINGS BEFORE OPERATING THIS TOOL FAILURE TO DO SO MAY RESULT IN PERSONAL INJURY AND OR PROPERTY DAMAGE AND WIL...

Страница 3: ...ment 12 Power tool plugs must match the outlet Never modify the plug in any way 13 Do not use any adapter plugs with grounded power tools 14 Do not abuse the cord Never use the cord for carrying pulli...

Страница 4: ...ifornia to cause cancer and birth defects or other reproductive harm Wash hands after handling California Health Safety Code 25249 5 et seq 15 Do not expose power tools to rain or wet conditions 16 If...

Страница 5: ...PERATING INSTRUCTIONS SET UP 1 Using wrench check that the soldering tip nuts are not loose Do not overtighten 2 The soldering gun comes with three soldering tips for different applications Select des...

Страница 6: ...ens WARNING If the supply cord of this power tool is damaged it must be replaced only by a qualified service technician 5 6 Brush on solder flux as needed to the workpiece Place the Soldering Tip to t...

Страница 7: ...ure B 2 Double insulated tools may be used in either of the 120 volt outlets shown in the following illustration See Figure B 3 This appliance has a polarized plug one blade is wider than the other To...

Страница 8: ...ly sized wire causes a serious drop in voltage resulting in loss of power and possible tool damage See table A 3 The smaller the gauge number of the wire the greater the capacity of the cord For examp...

Отзывы: